2015 Nov 21
2
Contact-closure UPS
>> On Nov 21, 2015, at 2:43 AM, R?bert SZAKSZ <robert at szaksz.eu> wrote:
>>
>> I mesured it and on DC and it shows 0 V (zero V).
>> May be the information (pls. see attachment) that UPS PIN1 should bee keept HI is mandatory. Should I connect it to PC PIN4 DTR?
>
>Certainly possible. blazer_ser and nutdrv_qx should set DTR high and RTS low by default, but
2015 Nov 21
0
Contact-closure UPS
...uot;UPS RxD"...
> Question for contact cable http://web.archive.org/web/20100106160328/http://ups.miem.edu.ru/ups_faq5.html type 5.2.1 is to set
> CP[RTS] OL[CTS] LB[DCD] SD[DTR] is this correct?
Probably. The testing procedure at http://www.networkupstools.org/docs/man/genericups.html#_testing_compatibility should help in case some of the signals need a "-".
--
Charles Lepple
clepple at gmail