Catching errors from solve() with near-singular matrices
...on number = 1.79977e-16 -- David C Sterratt, Research Fellow http://homepages.inf.ed.ac.uk/sterratt Institute for Adaptive and Neural Computation tel: +44 131 651 1739 School of Informatics, University of Edinburgh fax: +44 131 650 6899 Informatics Forum, 10 Crichton Street, Edinburgh EH8 9AB, Scotland * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * NEW BOOK: Principles of Computational Modelling in Neuroscience Sterratt, Graham, Gillies & Willshaw (CUP, 2011). http://www.compneuroprinciples.org The University of Edinburgh is a charitable body, registere...
2010 Feb 10
2
APC Smart-UPS 3000XL: Compatible/Any good?
Hello list. I'm contemplating buying new batteries and putting an older APC Smart-UPS 3000XL back into service. Would that work well with NUT? Any drawbacks to consider? Thank you, Tobias -- Tobias Balle-Petersen Kontrapunkt Group / System Administrator
2008 Jun 27
1
ietfmib.h patch and query
...: 883 bytes Desc: nut-ietfmib.patch Url : http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20080627/5812a62a/attachment.bin -------------- next part -------------- Dr George D M Ross, School of Informatics, University of Edinburgh 10 Crichton Street, Edinburgh, Scotland, EH8 9AB Mail: gdmr at inf.ed.ac.uk Voice: +44 131 650 5147 Fax: +44 131 651 1426 PGP: 1024D/AD758CC5 B91E D430 1E0D 5883 EF6A 426C B676 5C2B AD75 8CC5 The University of Edinburgh is a charitable body, registered in Scotland, with registration number SC005336. -------------- next part --------------...
2008 Sep 08
1
apcsmart and ambient data
Perhaps someone else could confirm this, I have an APC UPS with a built-in network management card with environmental sensor for temp/humidity. The OID index for the sensors appears to be .1 (the last component for each of the OIDs listed below). The original source code has them at .0 drivers/apccmib.h #define APCC_OID_IEM_TEMP ".1.3.6.1.4.1.318.1.1.10.2.3.2.1.4.1" #define
2012 May 11
1
Replacements for stdout and stderr guaranteed to be open in all versions of R
...lacements for stdout and stderr that work across all versions of R? All the best, David. -- David C Sterratt, Research Fellow. Tel: (+44) 131 651 1739 Institute for Adaptive and Neural Computation School of Informatics, University of Edinburgh Informatics Forum, 10 Crichton Street, Edinburgh EH8 9AB, Scotland, UK
2012 Feb 02
2
APC SmartUPS 3000VA LCD not connecting
We recently had to replace an old APC SmartUPS 3000 with a newer 3000VA (the 2U one). It has both serial and USB in the back (with an RJ-45 on the end of the serial cable). I can't get the apcsmart driver to connect. I figured it should work the exact same as the old UPS, with /dev/ttyS0 as the port (I'm using the same port on the server that the last one was plugged into). I even
2010 Jul 30
4
Concept questions: Extra battery packs & additional UPSes...
* Is there a way to configure NUT so that it recognizes the huge additional battery pack that has been attached to the 2200XL? The 51minutes runtime is a number consistent with the load we have placed on a stock standalone 2200XL. With the extra large battery pack we've added, the runtime should be more than 2.5 hours. * I see the "Bizzare configuration" graphic on the