APC Smart-UPS 3000XL: Compatible/Any good?
Hello list.
I'm contemplating buying new batteries and putting an older APC
Smart-UPS 3000XL back into service. Would that work well with NUT? Any
drawbacks to consider?
Thank you,
Tobias
--
Tobias Balle-Petersen
Kontrapunkt Group / System Administrator
2008 Jun 27
1
ietfmib.h patch and query
...: 883 bytes
Desc: nut-ietfmib.patch
Url : http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20080627/5812a62a/attachment.bin
-------------- next part --------------
Dr George D M Ross, School of Informatics, University of Edinburgh
10 Crichton Street, Edinburgh, Scotland, EH8 9AB
Mail: gdmr at inf.ed.ac.uk Voice: +44 131 650 5147 Fax: +44 131 651 1426
PGP: 1024D/AD758CC5 B91E D430 1E0D 5883 EF6A 426C B676 5C2B AD75 8CC5
The University of Edinburgh is a charitable body, registered in
Scotland, with registration number SC005336.
-------------- next part --------------...
2008 Sep 08
1
apcsmart and ambient data
Perhaps someone else could confirm this, I have an APC UPS with a built-in network management card with environmental sensor for temp/humidity. The OID index for the sensors appears to be .1 (the last component for each of the OIDs listed below). The original source code has them at .0
drivers/apccmib.h
#define APCC_OID_IEM_TEMP ".1.3.6.1.4.1.318.1.1.10.2.3.2.1.4.1"
#define
2012 May 11
1
Replacements for stdout and stderr guaranteed to be open in all versions of R
...lacements for stdout and
stderr that work across all versions of R?
All the best,
David.
--
David C Sterratt, Research Fellow. Tel: (+44) 131 651 1739
Institute for Adaptive and Neural Computation
School of Informatics, University of Edinburgh
Informatics Forum, 10 Crichton Street, Edinburgh EH8 9AB, Scotland, UK
2012 Feb 02
2
APC SmartUPS 3000VA LCD not connecting
We recently had to replace an old APC SmartUPS 3000 with a newer 3000VA
(the 2U one). It has both serial and USB in the back (with an RJ-45 on
the end of the serial cable).
I can't get the apcsmart driver to connect. I figured it should work
the exact same as the old UPS, with /dev/ttyS0 as the port (I'm using
the same port on the server that the last one was plugged into). I even
2010 Jul 30
4
Concept questions: Extra battery packs & additional UPSes...
* Is there a way to configure NUT so that it recognizes the huge
additional battery pack that has been attached to the 2200XL? The
51minutes runtime is a number consistent with the load we have placed on
a stock standalone 2200XL. With the extra large battery pack we've
added, the runtime should be more than 2.5 hours.
* I see the "Bizzare configuration" graphic on the