2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
Hello all, been 5 years since I posted on this list, glad to be back :) I have a number of X-power Tigra 1kVA online UPS units. From some knowledgeable folks working for the local distributor, I learnt that from inside this looked like a Best 610 ups unit. Before, I had this UPS hooked via serial to my Windows 2003 server. For monitoring, some winpilot/upspilot software was also provided. This softwar...
2010 Feb 08
1
megatec and blazer drivers for (brand)Tuncmatik (series)Newtech Pro 1KVA
Hi, I would like to report that Tuncmatik Newtech Pro 1 KVA (http://www.tuncmatik.com/en-US/productDetail.asp?RecID=290) works with nut(2.4.1) blazer_usb, blazer_ser and megatec drivers. The UPS came with an usb cable and a java based software for both linux and windows, named ViewPower (http://www-power-software-download.com). This UPS has double interface a USB interface and a serial
2006 Sep 19
2
help w/ Powerware Prestige 9
Hi, I've got a Powerware Prestige 9 1kVA UPS that seems to not be working with nut. It's not in the current "supported hardware" list, but the old bcmxcp page lists it as being a UPS that speaks that protocol. I have the following in my ups.conf [powerware] driver = bcmxcp port = /dev/ttyS0 desc = "Powerware Presti...
2012 May 10
2
Two servers with redundant supplies on two UPSs
Scenario: * Two windows 2003 servers (different models) * Each server has two PSUs * Each server has a single serial port * Two UPSs are available of the exact same type (XPower Tigra 1kVA). Each has a serial port * The 1st PSU of each server is powered by the 1st UPS * The 2nd PSU of each server is powered by the 2nd UPS I am trying to install NUT on the best "optimal" way for these two systems. My obvious solution so far is: Implementation 1: * Connect 1st ups via ser...
2006 Apr 06
4
Square One QP1010
Hi guys, Please bare with me, as this is my first attempt at setting up a UPS under Linux. I've been trying to setup a UPS on one of my clients servers. The model of the UPS is a Square one QP1000/QP1010 1Kva I've looked on the following link http://eu1.networkupstools.org/compat/stable.html It says that it should be compatible with the "powermust" driver, then in my /etc/nut/driver.list this driver doesn't exist. I've searched around quite a bit and from what I've found,...
2018 Sep 03
0
Adding drivers to NUT?
...ds? > > Keor PDU is a commercial name for a Rack UPS, in the USB_DEVICE() macro I tried to add a small description, I don't know if it's enough for you, what kind of comment would you like? > > Regarding nutdrv_qx the only VID:PID combo is for one family: "Legrand Daker DK+ 1kVA / 2kVA / 3kVA / 5kVA / 6kVA / 10kVA". This could be the description. > The items were Static, so I changed the file accordingly, i also added the DEFAULT_ONDELAY and DEFAULT_OFFDELAY. Probably i forgot it in a first time! > These are the changes related to questions Nr. 1,2,3,4 of your p...
2023 Sep 23
1
Nut-upsdev Digest, Vol 206, Issue 5
...ing ?? 0.016626??? No matching HID UPS found ?? 0.016658??? [D5] send_to_all: SETINFO driver.state "cleanup.exit" root at LOULOU:/tmp/nut# ./drivers/huawei-ups2000 -DDDDDD -d1 -s test -x port=auto -x vendorid=... -x productid=... -x subdriver=... Network UPS Tools - NUT Huawei UPS2000 (1kVA-3kVA) RS-232 Modbus driver 0.05 (2.8.0-2557-g81fca30b2) Warning: This is an experimental driver. Some features may not function correctly. ?? 0.000000??? [D3] main_arg: var='port' val='auto' ?? 0.000049??? [D6] testinfo_reloadable: var=port, infoname=driver.parameter.port, newv...
2023 Sep 23
1
Nut-upsdev Digest, Vol 206, Issue 5
...No matching HID UPS found > 0.016658 [D5] send_to_all: SETINFO driver.state "cleanup.exit" > root at LOULOU:/tmp/nut# ./drivers/huawei-ups2000 -DDDDDD -d1 -s test -x > port=auto -x vendorid=... -x productid=... -x subdriver=... > Network UPS Tools - NUT Huawei UPS2000 (1kVA-3kVA) RS-232 Modbus driver > 0.05 (2.8.0-2557-g81fca30b2) > Warning: This is an experimental driver. > Some features may not function correctly. > > 0.000000 [D3] main_arg: var='port' val='auto' > 0.000049 [D6] testinfo_reloadable: var=port, > infona...
2013 May 15
2
APC AP9617 SNMP returns strange errors
...correctly. We cannot set any values but read them all. community is ok as I can see auth messages in the ups if I use the wrong community. When get those errors above, I do not see any errors in the UPS' logs. I have no clue what's happening here. I can see this on both UPS which have 1kVA and 1.5kVA and AP9617 (that is the same as AP9618 that is supported with the exception of env montoring). We are using Debain wheezy (not yet the stable) and nut 2.6.4-1 and snmp-stuff 5.4.3-dfsg-2.5. Is there someone who can help, please?! Thanks a lot, -lutzn
2005 Jan 24
12
UPS for Asterisk
I have several Linux machines some running on really old hardware and some on brand new, some run old distros (RedHat 6) and some new (FC3 or CentOS). All of them experienced power failure more then once, none of them has failed to load after a reboot. BUT, Asterisk is running your PBX. Your PBX isn't your proxy server, it isn't your web server, mail server, firewall, or whatever
2023 Sep 19
1
Nut-upsdev Digest, Vol 206, Issue 5
...t;> I don't know what i'm doing wrong but it seams that is not working, >> >> I tried to put and remove id but it's not fonctioning, >> >> /etc/nut/ups.conf >> >> " >> >> pollinterval = 1 >> maxretry = 3 >> >> [ups1kva] >> driver = huawei-ups2000 >> port auto >> vendorid = "04e2" >> productid = "1410" >> " >> >> Then i use this commands for rebooting the drivers >> >> https://techno-tim.github.io/posts/N...
2008 Oct 27
1
Megatec and Batteries
...your UPS tells you battery voltage over megatec driver he tells you actually charged value of its battery bank. This information can be told in two ways: as a voltage sum of whole bank or as average value per battery cell. In first case you may get 38.6V in a second case 2.14V for the same on-line 1kVA UPS. This depend on how manufacturer implemented it. This gets me to megatec driver and how it see battery voltage. I think that this is job for someone to improve megatec driver in order to look at some table to see battery charged value or to create it with parameters to driver. Since I t...
2018 Jul 26
5
Adding drivers to NUT?
Dear Daniele, nice to meet you, I'm a collegue of Gabriele. The problem with "blazer_usb" driver ("blazer_ser" works correctly) is related to the following commands: - "F" and "I": when the KRAULER subdriver check these UPS answers it uses wrong constants to check the lenght of the received packets, so these commands are considered as "not