search for: 021150

Displaying 6 results from an estimated 6 matches for "021150".

Did you mean: 02110
2020 Jan 27
3
System with MGE UPS shuts down too early
...A 0.0 > 20200125 021128 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > So, it seems to me that my UPS forces shutdown pretty randomly. Why > the UPS is not waiting for the preset low battery charge value of 15%? > What is actually driving this FSD ALARM and LB signal when batteries > for sure could hold up more?...
2020 Jan 24
2
System with MGE UPS shuts down too early
On January 24, 2020 6:13:31 PM GMT+02:00, "Georgi D. Sotirov" <gdsotirov at gmail.com> wrote: >OK, my UPS turned out to be older that I thought. I apparently bought >and installed it in September 2016 (not 2017 as I initially wrote). >That >makes for over 3 years of work, which is over the life expectancy of >the >batteries, Good batteries can last 4-5 years.
2006 Jan 17
2
IAX/SIP and openser problem. IAX bug?
...d: I'm terribly sorry, server error occurred (1/SL) I got nex sip messages: U 2006/01/16 12:21:10.968713 10.2.11.35:5062 -> 10.2.11.35:5060 INVITE sip:204@10.2.11.35 SIP/2.0..Via: SIP/2.0/UDP 10.2.11.35:5062;branch=z9hG4bK31f811a3;rport..From: "Zyxel" <sip:Zyxel<sip:204@1021150;user=phone@10.2.11.35:5062>;tag=as56432543..To: <sip:204@10.2.11.35>..Contact: <sip:Zyxel<sip:204@1 021150;user=phone@10.2.11.35:5062>..Call-ID: 7bf16eeb00aca5cd2bd303a93f59bfc4@10.2.11.35..CSeq: 102 INVITE..User-Agent: Asterisk PBX..Max-Forwards: 70..Date: Mon, 16 Jan 2006 1...
2020 Jan 27
1
Nut-upsuser Digest, Vol 175, Issue 30
...8 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > > > So, it seems to me that my UPS forces shutdown pretty randomly. Why the > > UPS is not waiting for the preset low battery charge value of 15%? What > is > > actually driving this FSD ALARM and LB signal when batteries for sure &g...
2020 Jan 27
0
System with MGE UPS shuts down too early
...A 0.0 > 20200125 021128 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0 > > So, it seems to me that my UPS forces shutdown pretty randomly. Why the > UPS is not waiting for the preset low battery charge value of 15%? What is > actually driving this FSD ALARM and LB signal when batteries for sure could > hold up more? &g...
2020 Jan 25
0
System with MGE UPS shuts down too early
...200125 021123 70 0.0 16 [OB] NA 0.0 20200125 021128 69 0.0 16 [FSD ALARM OB LB] NA 0.0 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0 So, it seems to me that my UPS forces shutdown pretty randomly. Why the UPS is not waiting for the preset low battery charge value of 15%? What is actually driving this FSD ALARM and LB signal when batteries for sure could hold up more? Regards, -- Georgi O...