System with MGE UPS shuts down too early
...A 0.0
> 20200125 021128 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0
>
> So, it seems to me that my UPS forces shutdown pretty randomly. Why
> the UPS is not waiting for the preset low battery charge value of 15%?
> What is actually driving this FSD ALARM and LB signal when batteries
> for sure could hold up more?...
2020 Jan 24
2
System with MGE UPS shuts down too early
On January 24, 2020 6:13:31 PM GMT+02:00, "Georgi D. Sotirov" <gdsotirov at gmail.com> wrote:
>OK, my UPS turned out to be older that I thought. I apparently bought
>and installed it in September 2016 (not 2017 as I initially wrote).
>That
>makes for over 3 years of work, which is over the life expectancy of
>the
>batteries,
Good batteries can last 4-5 years.
2006 Jan 17
2
IAX/SIP and openser problem. IAX bug?
...d: I'm terribly sorry, server error occurred
(1/SL)
I got nex sip messages:
U 2006/01/16 12:21:10.968713 10.2.11.35:5062 -> 10.2.11.35:5060
INVITE sip:204@10.2.11.35 SIP/2.0..Via: SIP/2.0/UDP
10.2.11.35:5062;branch=z9hG4bK31f811a3;rport..From: "Zyxel"
<sip:Zyxel<sip:204@1021150;user=phone@10.2.11.35:5062>;tag=as56432543..To:
<sip:204@10.2.11.35>..Contact: <sip:Zyxel<sip:204@1
021150;user=phone@10.2.11.35:5062>..Call-ID:
7bf16eeb00aca5cd2bd303a93f59bfc4@10.2.11.35..CSeq: 102 INVITE..User-Agent:
Asterisk PBX..Max-Forwards: 70..Date: Mon, 16 Jan 2006 1...
2020 Jan 27
1
Nut-upsuser Digest, Vol 175, Issue 30
...8 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> > 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> > 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> > 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> > 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> > 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> >
> > So, it seems to me that my UPS forces shutdown pretty randomly. Why the
> > UPS is not waiting for the preset low battery charge value of 15%? What
> is
> > actually driving this FSD ALARM and LB signal when batteries for sure
&g...
2020 Jan 27
0
System with MGE UPS shuts down too early
...A 0.0
> 20200125 021128 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0
> 20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0
>
> So, it seems to me that my UPS forces shutdown pretty randomly. Why the
> UPS is not waiting for the preset low battery charge value of 15%? What is
> actually driving this FSD ALARM and LB signal when batteries for sure could
> hold up more?
&g...
2020 Jan 25
0
System with MGE UPS shuts down too early
...200125 021123 70 0.0 16 [OB] NA 0.0
20200125 021128 69 0.0 16 [FSD ALARM OB LB] NA 0.0
20200125 021133 69 0.0 16 [FSD ALARM OB LB] NA 0.0
20200125 021138 69 0.0 16 [FSD ALARM OB LB] NA 0.0
20200125 021143 69 0.0 16 [FSD ALARM OB LB] NA 0.0
20200125 021148 69 0.0 16 [FSD ALARM OB LB] NA 0.0
20200125 021150 69 0.0 16 [FSD ALARM OB LB] NA 0.0
So, it seems to me that my UPS forces shutdown pretty randomly. Why the
UPS is not waiting for the preset low battery charge value of 15%? What
is actually driving this FSD ALARM and LB signal when batteries for sure
could hold up more?
Regards,
--
Georgi
O...