Hi, i've got similar problem with an OVISLINK 1000VA UPS on Debian. I've tried to connect with it using different drivers and this is what I get with each of them: [UPS] driver = blazer_usb vendorid = 0001 productid = 0000 port = auto subdriver = phoenix sweethome:~# /lib/nut/blazer_usb -a UPS -u root -DDD Network UPS Tools - Megatec/Q1 protocol USB driver 0.08 (2.6.4) 0.000000 debug level is '3' 0.171290 Checking device (1D6B/0001) (005/001) 0.171346 - VendorID: 1d6b 0.171353 - ProductID: 0001 0.171358 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.171363 - Product: UHCI Host Controller 0.171368 - Serial Number: 0000:00:10.3 0.171372 - Bus: 005 0.171377 Trying to match device 0.171390 Device does not match - skipping 0.171400 Checking device (1D6B/0001) (004/001) 0.171420 - VendorID: 1d6b 0.171426 - ProductID: 0001 0.171431 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.171436 - Product: UHCI Host Controller 0.171441 - Serial Number: 0000:00:10.2 0.171446 - Bus: 004 0.171450 Trying to match device 0.171456 Device does not match - skipping 0.171463 Checking device (1D6B/0001) (003/001) 0.171482 - VendorID: 1d6b 0.171488 - ProductID: 0001 0.171493 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.171497 - Product: UHCI Host Controller 0.171502 - Serial Number: 0000:00:10.1 0.171507 - Bus: 003 0.171511 Trying to match device 0.171517 Device does not match - skipping 0.171524 Checking device (0001/0000) (002/005) 0.209728 - VendorID: 0001 0.209738 - ProductID: 0000 0.209743 - Manufacturer: ATCL FOR UPS 0.209747 - Product: ATCL FOR UPS 0.209752 - Serial Number: ATCL FOR UPS 0.209756 - Bus: 002 0.209761 Trying to match device 0.209802 Device matches 0.218750 Trying megatec protocol... 2.011770 flush: No error 2.015287 send: Q1 3.059778 read: No error 3.059984 blazer_status: short reply 3.060090 Status read 1 failed 4.107789 flush: No error 4.111775 send: Q1 5.163801 read: No error 5.164007 blazer_status: short reply 5.164116 Status read 2 failed 6.211812 flush: No error 6.215799 send: Q1 7.259823 read: No error 7.260021 blazer_status: short reply 7.260129 Status read 3 failed 7.260224 Trying mustek protocol... 8.307832 flush: No error 8.311822 send: QS 9.355847 read: No error 9.356053 blazer_status: short reply 9.356168 Status read 1 failed 10.403860 flush: No error 10.407846 send: QS 11.451870 read: No error 11.452069 blazer_status: short reply 11.452177 Status read 2 failed 12.499880 flush: No error 12.503868 send: QS 13.547892 read: No error 13.548090 blazer_status: short reply 13.548198 Status read 3 failed 13.548295 Trying megatec/old protocol... 14.595901 flush: No error 14.599892 send: D 15.651914 read: No error 15.652110 blazer_status: short reply 15.652219 Status read 1 failed 16.699927 flush: No error 16.703915 send: D 17.747941 read: No error 17.748138 blazer_status: short reply 17.748252 Status read 2 failed 18.795947 flush: No error 18.799938 send: D 19.843961 read: No error 19.844147 blazer_status: short reply 19.844255 Status read 3 failed 19.844350 Trying zinto protocol... 20.891970 flush: No error 20.895962 send: Q1 21.939989 read: No error 21.940197 blazer_status: short reply 21.940307 Status read 1 failed 22.988001 flush: No error 22.991986 send: Q1 24.036013 read: No error 24.036220 blazer_status: short reply 24.036329 Status read 2 failed 25.084022 flush: No error 25.088009 send: Q1 26.132034 read: No error 26.132245 blazer_status: short reply 26.132354 Status read 3 failed 26.132451 No supported UPS detected ------------------------------------------------------------------------------------------------------------------------------ [UPS] driver = blazer_usb vendorid = 0001 productid = 0000 port = auto subdriver = cypress sweethome:~# /lib/nut/blazer_usb -a UPS -u root -DDD Network UPS Tools - Megatec/Q1 protocol USB driver 0.08 (2.6.4) 0.000000 debug level is '3' 0.171948 Checking device (1D6B/0001) (005/001) 0.171999 - VendorID: 1d6b 0.172005 - ProductID: 0001 0.172010 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.172015 - Product: UHCI Host Controller 0.172020 - Serial Number: 0000:00:10.3 0.172025 - Bus: 005 0.172029 Trying to match device 0.172044 Device does not match - skipping 0.172052 Checking device (1D6B/0001) (004/001) 0.172073 - VendorID: 1d6b 0.172078 - ProductID: 0001 0.172083 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.172088 - Product: UHCI Host Controller 0.172093 - Serial Number: 0000:00:10.2 0.172097 - Bus: 004 0.172102 Trying to match device 0.172108 Device does not match - skipping 0.172115 Checking device (1D6B/0001) (003/001) 0.172135 - VendorID: 1d6b 0.172140 - ProductID: 0001 0.172145 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.172150 - Product: UHCI Host Controller 0.172154 - Serial Number: 0000:00:10.1 0.172159 - Bus: 003 0.172164 Trying to match device 0.172169 Device does not match - skipping 0.172176 Checking device (0001/0000) (002/005) 0.209545 - VendorID: 0001 0.209569 - ProductID: 0000 0.209575 - Manufacturer: ATCL FOR UPS 0.209579 - Product: ATCL FOR UPS 0.209584 - Serial Number: ATCL FOR UPS 0.209589 - Bus: 002 0.209593 Trying to match device 0.209651 Device matches 0.218562 Trying megatec protocol... 0.222558 send: Q1 2.017580 read: No error 2.017777 blazer_status: short reply 2.017886 Status read 1 failed 2.021564 send: Q1 3.065586 read: No error 3.065777 blazer_status: short reply 3.065886 Status read 2 failed 3.069577 send: Q1 4.121598 read: No error 4.121790 blazer_status: short reply 4.121898 Status read 3 failed 4.121993 Trying mustek protocol... 4.125588 send: QS 5.169610 read: No error 5.169807 blazer_status: short reply 5.169914 Status read 1 failed 5.173599 send: QS 6.217621 read: No error 6.217796 blazer_status: short reply 6.217869 Status read 2 failed 6.221611 send: QS 7.265638 read: No error 7.265828 blazer_status: short reply 7.265903 Status read 3 failed 7.265975 Trying megatec/old protocol... 7.269623 send: D 8.313647 read: No error 8.313864 blazer_status: short reply 8.313952 Status read 1 failed 8.317633 send: D 9.361659 read: No error 9.361860 blazer_status: short reply 9.361969 Status read 2 failed 9.365646 send: D 10.409671 read: No error 10.409873 blazer_status: short reply 10.409981 Status read 3 failed 10.410068 Trying zinto protocol... 10.413657 send: Q1 11.457682 read: No error 11.457884 blazer_status: short reply 11.457993 Status read 1 failed 11.461670 send: Q1 12.505693 read: No error 12.505896 blazer_status: short reply 12.506004 Status read 2 failed 12.509682 send: Q1 13.553705 read: No error 13.553905 blazer_status: short reply 13.554013 Status read 3 failed 13.554116 No supported UPS detected ------------------------------------------------------------------------------------------------------------------------------ [UPS] driver = blazer_usb vendorid = 0001 productid = 0000 port = auto subdriver = ippon sweethome:~# /lib/nut/blazer_usb -a UPS -u root -DDD Network UPS Tools - Megatec/Q1 protocol USB driver 0.08 (2.6.4) 0.000000 debug level is '3' 0.169181 Checking device (1D6B/0001) (005/001) 0.169243 - VendorID: 1d6b 0.169249 - ProductID: 0001 0.169254 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.169259 - Product: UHCI Host Controller 0.169264 - Serial Number: 0000:00:10.3 0.169269 - Bus: 005 0.169274 Trying to match device 0.169291 Device does not match - skipping 0.169300 Checking device (1D6B/0001) (004/001) 0.169321 - VendorID: 1d6b 0.169327 - ProductID: 0001 0.169332 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.169337 - Product: UHCI Host Controller 0.169341 - Serial Number: 0000:00:10.2 0.169346 - Bus: 004 0.169351 Trying to match device 0.169356 Device does not match - skipping 0.169364 Checking device (1D6B/0001) (003/001) 0.169384 - VendorID: 1d6b 0.169390 - ProductID: 0001 0.169394 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.169399 - Product: UHCI Host Controller 0.169404 - Serial Number: 0000:00:10.1 0.169409 - Bus: 003 0.169413 Trying to match device 0.169419 Device does not match - skipping 0.169427 Checking device (0001/0000) (002/005) 0.206568 - VendorID: 0001 0.206578 - ProductID: 0000 0.206582 - Manufacturer: ATCL FOR UPS 0.206587 - Product: ATCL FOR UPS 0.206592 - Serial Number: ATCL FOR UPS 0.206597 - Bus: 002 0.206601 Trying to match device 0.206643 Device matches 0.215589 Trying megatec protocol... 0.218582 send: error sending control message: Broken pipe 0.221173 Stall condition cleared 0.221183 blazer_status: short reply 0.221189 Status read 1 failed 0.223570 send: error sending control message: Broken pipe 0.226567 Stall condition cleared 0.226576 blazer_status: short reply 0.226581 Status read 2 failed 0.229571 send: error sending control message: Broken pipe 0.232567 Stall condition cleared 0.232576 blazer_status: short reply 0.232581 Status read 3 failed 0.232585 Trying mustek protocol... 0.234569 send: error sending control message: Broken pipe 0.237567 Stall condition cleared 0.237576 blazer_status: short reply 0.237581 Status read 1 failed 0.240570 send: error sending control message: Broken pipe 0.242567 Stall condition cleared 0.242575 blazer_status: short reply 0.242580 Status read 2 failed 0.245571 send: error sending control message: Broken pipe 0.248578 Stall condition cleared 0.248588 blazer_status: short reply 0.248595 Status read 3 failed 0.248601 Trying megatec/old protocol... 0.250569 send: error sending control message: Broken pipe 0.253568 Stall condition cleared 0.253576 blazer_status: short reply 0.253582 Status read 1 failed 0.256569 send: error sending control message: Broken pipe 0.258568 Stall condition cleared 0.258577 blazer_status: short reply 0.258582 Status read 2 failed 0.261571 send: error sending control message: Broken pipe 0.264568 Stall condition cleared 0.264576 blazer_status: short reply 0.264581 Status read 3 failed 0.264586 Trying zinto protocol... 0.266569 send: error sending control message: Broken pipe 0.269567 Stall condition cleared 0.269675 blazer_status: short reply 0.269784 Status read 1 failed 0.272570 send: error sending control message: Broken pipe 0.275567 Stall condition cleared 0.275642 blazer_status: short reply 0.275748 Status read 2 failed 0.278570 send: error sending control message: Broken pipe 0.281568 Stall condition cleared 0.281631 blazer_status: short reply 0.281650 Status read 3 failed 0.281689 No supported UPS detected ------------------------------------------------------------------------------------------------------------------------------ [UPS] driver = blazer_usb vendorid = 0001 productid = 0000 port = auto subdriver = krauler /lib/nut/blazer_usb -a UPS -u root -DDD Network UPS Tools - Megatec/Q1 protocol USB driver 0.08 (2.6.4) 0.000000 debug level is '3' 0.172398 Checking device (1D6B/0001) (005/001) 0.172455 - VendorID: 1d6b 0.172461 - ProductID: 0001 0.172466 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.172471 - Product: UHCI Host Controller 0.172476 - Serial Number: 0000:00:10.3 0.172481 - Bus: 005 0.172485 Trying to match device 0.172499 Device does not match - skipping 0.172509 Checking device (1D6B/0001) (004/001) 0.172529 - VendorID: 1d6b 0.172535 - ProductID: 0001 0.172539 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.172544 - Product: UHCI Host Controller 0.172549 - Serial Number: 0000:00:10.2 0.172554 - Bus: 004 0.172558 Trying to match device 0.172564 Device does not match - skipping 0.172572 Checking device (1D6B/0001) (003/001) 0.172592 - VendorID: 1d6b 0.172597 - ProductID: 0001 0.172601 - Manufacturer: Linux 3.2.0-2-amd64 uhci_hcd 0.172606 - Product: UHCI Host Controller 0.172611 - Serial Number: 0000:00:10.1 0.172615 - Bus: 003 0.172620 Trying to match device 0.172625 Device does not match - skipping 0.172633 Checking device (0001/0000) (002/005) 0.208482 - VendorID: 0001 0.208492 - ProductID: 0000 0.208497 - Manufacturer: ATCL FOR UPS 0.208502 - Product: ATCL FOR UPS 0.208507 - Serial Number: ATCL FOR UPS 0.208512 - Bus: 002 0.208516 Trying to match device 0.208557 Device matches 0.217502 Trying megatec protocol... 0.217513 send: Q1 0.225496 read: error sending control message: Broken pipe 0.228482 Stall condition cleared 0.228492 blazer_status: short reply 0.228497 Status read 1 failed 0.228502 send: Q1 0.235484 read: error sending control message: Broken pipe 0.238482 Stall condition cleared 0.238491 blazer_status: short reply 0.238497 Status read 2 failed 0.238502 send: Q1 0.246483 read: error sending control message: Broken pipe 0.249481 Stall condition cleared 0.249490 blazer_status: short reply 0.249495 Status read 3 failed 0.249500 Trying mustek protocol... 0.249505 send: QS 0.249510 read: QS 0.249520 blazer_status: short reply 0.249526 Status read 1 failed 0.249530 send: QS 0.249535 read: QS 0.249540 blazer_status: short reply 0.249545 Status read 2 failed 0.249549 send: QS 0.249554 read: QS 0.249559 blazer_status: short reply 0.249564 Status read 3 failed 0.249569 Trying megatec/old protocol... 0.249574 send: D 0.249578 read: D 0.249583 blazer_status: short reply 0.249588 Status read 1 failed 0.249593 send: D 0.249598 read: D 0.249602 blazer_status: short reply 0.249607 Status read 2 failed 0.249612 send: D 0.249617 read: D 0.249621 blazer_status: short reply 0.249626 Status read 3 failed 0.249631 Trying zinto protocol... 0.249636 send: Q1 0.257483 read: error sending control message: Broken pipe 0.260482 Stall condition cleared 0.260492 blazer_status: short reply 0.260498 Status read 1 failed 0.260503 send: Q1 0.267483 read: error sending control message: Broken pipe 0.270481 Stall condition cleared 0.270491 blazer_status: short reply 0.270496 Status read 2 failed 0.270502 send: Q1 0.278483 read: error sending control message: Broken pipe 0.281481 Stall condition cleared 0.281490 blazer_status: short reply 0.281495 Status read 3 failed 0.281500 No supported UPS detected ------------------------------------------------------------------------------------------------------------------------------ anybody can help with this? What else can I try?
2012/8/7 Rojo Alvarez, ?lex <alex.rojo at ikusi.com>> Hi, >Hi ?lex> i've got similar problem with an OVISLINK 1000VA UPS on Debian. >could you please elaborate on the "similarity"? I'm not sure to see your reference here...> I've tried to connect with it using different drivers and this is what I > get with each of them: > (...) >Before going in the depth of the Q1 protocol, I'd like to see a verbose lsusb output: # lsusb -v -d0001:0000 I've had a similar report this week end (search for "Zigor Ebro 650 compatibility" on nut-upsusers). The device here seems to be a real HID unit, so supported by a different driver (namely "usbhid-ups"). cheers, Arnaud -- Linux / Unix / Opensource Engineering Expert - Eaton - http://opensource.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120813/331feff8/attachment.html>
Hi 2012/8/19 Rojo Alvarez, ?lex <alex.rojo at ikusi.com>> Hi, > these are the new tests keeping "langid_fix = 0x4095" and changing > subdrivers as you told me. >sorry, wrong copy/paste on my side. the base comment was good ("first thing, 0x409 seems to be the one to select"), but not the provided config. can you please test it again with "langid_fix = 0x409"? cheers, Arnaud -- Linux / Unix / Opensource Engineering Expert - Eaton - http://opensource.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120905/a1801d77/attachment.html>