Device manufacturer: GE Digital Energy (http://www.gedigitalenergy.com/powerquality/catalog/rackmountnet.htm) Device name: GE EP6000R (http://www.gedigitalenergy.com/powerquality/catalog/rackmountnet.htm) *upsc:* * battery.voltage: 272.40 * battery.voltage.nominal: 240.0 * beeper.status: disabled * device.type: ups * driver.name: blazer_usb * driver.parameter.bus: 004 * driver.parameter.pollinterval: 2 * driver.parameter.port: auto * driver.version: 2.6.0 * driver.version.internal: 0.03 * input.current.nominal: 27.0 * input.frequency: 50.0 * input.frequency.nominal: 50 * input.voltage: 233.0 * input.voltage.fault: 140.0 * input.voltage.nominal: 220 * output.voltage: 220.0 * ups.delay.shutdown: 30 * ups.delay.start: 180 * ups.load: 2 * ups.productid: 00c9 * ups.status: OL * ups.temperature: 32.0 * ups.type: online * ups.vendorid: 14f0 *upscmd -l:* Instant commands supported on UPS [ups1]: * beeper.toggle - Toggle the UPS beeper -> returns OK, but seems to have no effect * load.off - Turn off the load immediately -> returns OK, but seems to have no effect * load.on - Turn on the load immediately -> returns OK, but seems to have no effect * shutdown.return - Turn off the load and return when power is back -> returns OK, but seems to have no effect * shutdown.stayoff - Turn off the load and remain off -> returns OK, but seems to have no effect * shutdown.stop - Stop a shutdown in progress -> returns OK, but seems to have no effect * test.battery.start - Start a battery test -> OK, starts a test, UPS status changes to 'OL CAL' (didn't wait for the test to finish) * test.battery.start.deep - Start a deep battery test -> returns OK, starts a test, UPS status changes to 'OL CAL' (didn't wait for the test to finish) * test.battery.start.quick - Start a quick battery test -> returns OK, starts a test, UPS status changes to 'OL CAL' for a short time * test.battery.stop - Stop the battery test - OK, stops a test, UPS status changes back to 'OL' NOTE - issuing several 'test.battery.start*' commands without 'test.battery.stop' kills USB communication. The UPS needs to be disconnected and re-connected to USB before communication can be re-established. *upsrw* - no output I couldn't test the shutdown procedure as we also have a generating set - hopefully I'll never see the shutdown procedure. Best regards, Danilo -- Danilo Godec, sistemska podpora / system administration Predlog! Obiscite prenovljeno spletno stran www.agenda.si ODPRTA KODA IN LINUX STORITVE : POSLOVNE RESITVE : UPRAVLJANJE IT : INFRASTRUKTURA IT : IZOBRAZEVANJE : PROGRAMSKA OPREMA Visit our updated web page at www.agenda.si OPEN SOURCE AND LINUX SERVICES : BUSINESS SOLUTIONS : IT MANAGEMENT : IT INFRASTRUCTURE : TRAINING : SOFTWARE -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20110420/56975bfe/attachment.htm>