Olly Lappage
2007-Nov-08 12:55 UTC
[Nut-upsuser] UPS auto restart problem upgrading from nut 2.0.1-2.2.0 with MGE Pulsar EXtreme 700C
Hi, Apologies if this is a known problem. I have just joined the list and haven't done an exhaustive search of the archives. Also I am no UPS expert, so please excuse me if some of my terminology is poor. I use an MGE Pulsar Extreme 700C connected via RS232 to the linux server it powers. I have recently upgraded to a new linux distribution. Both new and old use 2.6 kernels, although the new one is about a year newer. When I did the upgrade I thought I may as well upgrade from nut 2.0.1 to 2.2.0 at the same time. My configuration instructs the UPS to shut down power to the load with a 40 second delay once my O/S is halted, then switch power on to the load when AC returns. I found that the UPS failed to resume power when I connected AC back to the UPS. I tested this a few times always with the same result. The UPS just sits there with the LED's slowly lighting in sequence then extinguishing in reverse sequence). upsdrvctl outputs the same text as it did previously just before shutdown. Can't remember what exactly, but something like "UPS responds auto restart request OK, UPS responds shutdown request OK". I compiled the 2.0.1 version of nut on the new O/S and everything works fine now. I'm quite happy to go on using the old version as I have had no problems with it at all in the last 2.5(ish) years but I thought this may be of interest to someone perhaps... I am assuming the problem is most likely to be with the updated MGE UPS driver. Cheers Olly. Info upsc reports from the unit: battery.charge: 100.0 battery.charge.low: 45 battery.runtime: 00768 battery.voltage: 027.3 battery.voltage.nominal: 024.0 driver.name: mge-utalk driver.parameter.port: /dev/ttyS1 driver.version: 2.0.1 driver.version.internal: 0.81.0 input.frequency: 50.00 input.voltage: 240.2 output.current: 001.3 output.voltage: 230.5 ups.delay.shutdown: 040 ups.delay.start: 060 ups.firmware: 16 ups.id: EXtreme 700C 16 ups.load: 052.0 ups.mfr: MGE UPS SYSTEMS ups.model: EXtreme 700C ups.status: OL CHRG ups.test.interval: 10080
Olly Lappage
2007-Nov-08 12:57 UTC
[Nut-upsuser] UPS auto restart problem upgrading from nut 2.0.1-2.2.0 with MGE Pulsar EXtreme 700C
Hi,> > Apologies if this is a known problem. I have just joined the list and > haven't done an exhaustive search of the archives. Also I am no UPS > expert, so please excuse me if some of my terminology is poor. > > I use an MGE Pulsar Extreme 700C connected via RS232 to the linux > server it powers. I have recently upgraded to a new linux > distribution. Both new and old use 2.6 kernels, although the new one > is about a year newer. > > When I did the upgrade I thought I may as well upgrade from nut 2.0.1 > to 2.2.0 at the same time. > > My configuration instructs the UPS to shut down power to the load with > a 40 second delay once my O/S is halted, then switch power on to the > load when AC returns. I found that the UPS failed to resume power > when I connected AC back to the UPS. I tested this a few times > always with the same result. The UPS just sits there with the LED's > slowly lighting in sequence then extinguishing in reverse sequence). > upsdrvctl outputs the same text as it did previously just before > shutdown. Can't remember what exactly, but something like "UPS > responds auto restart request OK, UPS responds shutdown request OK". > > I compiled the 2.0.1 version of nut on the new O/S and everything > works fine now. I'm quite happy to go on using the old version as I > have had no problems with it at all in the last 2.5(ish) years but I > thought this may be of interest to someone perhaps... I am assuming > the problem is most likely to be with the updated MGE UPS driver. > > Cheers > > Olly. > > > Info upsc reports from the unit: > > battery.charge: 100.0 > battery.charge.low: 45 > battery.runtime: 00768 > battery.voltage: 027.3 > battery.voltage.nominal: 024.0 > driver.name: mge-utalk > driver.parameter.port: /dev/ttyS1 > driver.version: 2.0.1 > driver.version.internal: 0.81.0 > input.frequency: 50.00 > input.voltage: 240.2 > output.current: 001.3 > output.voltage: 230.5 > ups.delay.shutdown: 040 > ups.delay.start: 060 > ups.firmware: 16 > ups.id: EXtreme 700C 16 > ups.load: 052.0 > ups.mfr: MGE UPS SYSTEMS > ups.model: EXtreme 700C > ups.status: OL CHRG > ups.test.interval: 10080