Michael C. Cambria
2007-Jan-15 17:17 UTC
[asterisk-users] S110M (FXS) Modules no longer seen on TDM400P
I have a TDM21B (A new TDM20B that just arrived plus a X100M that I already had). This card sometimes works, and sometimes only the FXO module is seen. (correction to previous message that incorrectly listed X400M/S400M when I'm using only the single port versions of these modules (X100M/S110M). By "works", I mean all 3 modules have the green lights on the ports on and when zaptel is loaded the log shows: Freshmaker version: 73 Freshmaker passed register test Module 0: Installed -- AUTO FXS/DPO Module 1: Installed -- AUTO FXS/DPO Module 2: Installed -- AUTO FXO (FCC mode) Module 3: Not installed Found a Wildcard TDM: Wildcard TDM400P REV I (3 modules) When things don't work, I either see: Indirect Registers failed verification. [deleted registers in question] Module 0: FAILED FXS (FCC) Indirect Registers failed verification. [deleted registers in question] Module 1: FAILED FXS (FCC) Module 2: Installed -- AUTO FXO (FCC mode) Module 3: Not installed Found a Wildcard TDM: Wildcard TDM400P REV I (1 modules) Or sometimes, I'd get nothing about FXS modules, and only log messages about the FXO working. I removed the FXO so that I have just what was just shipped to me. Now nothing is recognized. If I manually insmod zaptel, all I see is: Found a Wildcard TDM: Wildcard TDM400P REV I Any ideas? Before sending this card back, I'd like to make sure there isn't something else basic that I'm not doing. I did supply power to the TDM400P. That was the first thing I checked. Thanks, MikeC -- Michael C. Cambria email : mcc@fid4.com VoIP : sip:mcc@mcambria.fid4.com FWD : sip:63730@fwd.pulver.com WWW : www.fid4.com