Just added a new Grandstream BT102 to my network. Its running new firmware (Ver 1.0.5.22 of 2005-01-21). I could NOT get the damn thing to (SIP) register.... Gripe 1: The New Firmware does NOT show the current version of all the firmware. You have to ask the phone manually with its menu button. Gripe 2: It does not show '****' in the the two password fields... This is what caught me - I had two browser (tabbed) sessions and was switching between them - looking for differences... obvious the password fields now being blank look the same.. I never typed in the "Authenticate Password:" .... Doing so fixed the problem. If anyone from Grandstream lurks - can they change this behaviour? - at least fake some '***' in the password fields... Asterisk also had me chasing my tail - it never mentioned anything such as 'SIP Registration password is incorrect' - I got one.. chan_sip.c:7231 handle_request: Failed to authenticate user "Phone Five" <sip:phone5@asterisk.mydom.com;user=phone>;tag=fjhgkjhgkhjlk (OK - "failed authentication" - but something about the password would have been better) and got lots of... chan_sip.c:7588 handle_request: Registration from '<sip:phone5@asterisk.mydom.com;user=phone>' failed for '192.168.0.126' ... which had me "grep"ing around for the word "phone" (should this have not been "phone5" ??) -- . . ___. .__ Posix Systems - Sth Africa. e.164 VOIP ready /| /| / /__ mje@posix.co.za - Mark J Elkins, Cisco CCIE / |/ |ARK \_/ /__ LKINS Tel: +27 12 807 0590 Cell: +27 82 601 0496