I just installed two new X100P's today in my RH7.3 box and was poking around /proc What does the RED refer to on board 2? /proc/zaptel/1 Span 1: WCFXO/0 "Wildcard X101P Board 1" 1 WCFXO/0/0 /proc/zaptel/2 Span 2: WCFXO/1 "Wildcard X101P Board 2" RED 2 WCFXO/1/0 Any clues on how to setup channels on the two interfaces?? I am up to here in documentation...... --->incoming POTS->X100P->Asterisk/IVR->X100P-->Outgoing calls POTS-> -- Mark Street, D.C. Red Hat Certified Engineer Cert# 807302251406074 -- Key fingerprint = 3949 39E4 6317 7C3C 023E 2B1F 6FB3 06E7 D109 56C0 GPG key http://www.streetchiro.com/pubkey.asc
> What does the RED refer to on board 2? > > /proc/zaptel/1 > Span 1: WCFXO/0 "Wildcard X101P Board 1" > 1 WCFXO/0/0 > > /proc/zaptel/2 > Span 2: WCFXO/1 "Wildcard X101P Board 2" RED > 2 WCFXO/1/0Red alarm, on X100/X101P's this means "You don't seem to have a phone line plugged in"> Any clues on how to setup channels on the two interfaces?? I am up to > here in documentation......Follow the normal config, and in zaptel.conf put: fxsks=1-2 instead of just fxsks=1, and in zapata.conf add: channel => 1-2 instead of just channel => 1. Mark