[Nut-upsdev] Adding More Variables from the CyberPower MIB
As per https://github.com/networkupstools/nut/pull/1982 I'm looking to add a few more variables from the CyberPower SNMP MIB. At question in particular are the values added to the ups.status variable coming from the CPS-MIB::upsStatus.0 OID. These values are, from the MIB: upsStatus OBJECT-TYPE SYNTAX INTEGER { normal (1), overheat (2), hardwarefault (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The UPS system status." ::= { upsSystem 1 } and seem to reflect a handful of hardware error conditions. In the PR I've just made up a couple of values that will be appended to the status if present ("OH" (overheat) and "HW" (hardwarefault)) and are, I admit, relatively arcane. Feedback is welcomed. I would also consider that these conditions might be better served as alarms (ups.alarm) where, it seems, more descriptive messages are applicable. Thoughts? -- Craig Holyoak craig at helmsdeep.org http://www.helmsdeep.org/