[Nut-upsuser] testing shutdown: pc not restarting; and "ups unavailable" messages
Executive summary: I am installing a UPS with NUT on Ubuntu for the first time. I could follow the instructions up to "testing shutdowns" but on executing the recommended command the computer shuts down and never comes back on, contrary to what the instructions suggest. I am also seeing regular broadcast messages on the console that the UPS is unavailable (and in the? syslog that the connection timed out), although the physical USB connection seems to be OK. Where should I be looking to diagnose the fault? Details: OS: Ubuntu 16.04.3 LTS exact NUT version: nut is already the newest version (2.7.2-4ubuntu1.2). NUT installation method: from source tarball, package or Subversion: sudo apt install nut nut-monitor usbhid-ups exact device name and related information (manufacturing date, web pointers, ?), Cyber Power Value 800EILCD https://www.cyberpower.com/uk/en/product/sku/Value800EILCD complete problem description, with any relevant traces, like system log excerpts, and driver debug output. You can obtain the latter using the following command, as root and after having stopped NUT: I followed the instructions at http://networkupstools.org/docs/user-manual.chunked/ar01s06.html adjusting the paths as appropriate for ubuntu. However when I get to "Testing shutdowns" and "You can finally test a forced shutdown sequence [...] If everything works correctly, the computer will power on again". The latter does not happen. The computer shuts down and never comes back up unless I turn it back on manually at the power switch. The instructions then say that "If your UPS just sits there and never resets the load, you are vulnerable to a power race and should add the "reboot after timeout" hack at the very least." I presume this hack is the one in the code box a few lines above, namely ?if (test -f /etc/killpower) ??????? then ??????????????? echo "Killing the power, bye!" ??????????????? /usr/local/ups/bin/upsdrvctl shutdown ??????????????? sleep 120 ??????????????? # uh oh... the UPS power-off failed ??????????????? # you probably want to reboot here so you don't get stuck! ??????????????? # *** see also the section on power races in the FAQ! *** ??????? fi But two doubts about it: 1) should I still do it despite the warning above it that "this step is not need[ed] if you installed from packages", which I did? 2) If I am supposed to add this into my shutdown scripts, what is their path? I could not find that anywhere in the whole page by searching for "shutdown scripts". Finally, a possibly related and possibly unrelated issue is that I get a number of messages like this on the console Broadcast message from nut at sauron (somewhere) (Mon Jan 29 09:55:42 2018): UPS cyber at localhost is unavailable and in /var/log/syslog Jan 29 09:55:02 sauron upsmon[2385]: Poll UPS [cyber at localhost] failed - Data stale Jan 29 09:55:42 sauron upsmon[2385]: message repeated 8 times: [ Poll UPS [cyber at localhost] failed - Data stale] Jan 29 09:55:42 sauron upsmon[2385]: UPS cyber at localhost is unavailable Jan 29 09:55:47 sauron upsmon[2385]: Poll UPS [cyber at localhost] failed - Data stale Jan 29 09:55:52 sauron upsmon[2385]: Poll UPS [cyber at localhost] failed - Data stale Jan 29 09:55:56 sauron upsd[2377]: Send ping to UPS [cyber] failed: Resource temporarily unavailable Jan 29 09:55:57 sauron upsd[2377]: Connected to UPS [cyber]: usbhid-ups-cyber Jan 29 09:55:57 sauron upsmon[2385]: Poll UPS [cyber at localhost] failed - Driver not connected but occasionally it says it can connect: Jan 29 09:56:02 sauron upsmon[2385]: Communications with UPS cyber at localhost established Where should I be looking to find out what the problem is? Help and advice gratefully received.
Roger Price
2018-Feb-01 08:19 UTC
[Nut-upsuser] testing shutdown: pc not restarting; and "ups unavailable" messages
On Thu, 1 Feb 2018, nut.user.u830 at neverbox.com wrote:> I am installing a UPS with NUT on Ubuntu for the first time. I could > follow the instructions up to "testing shutdowns" but on executing the > recommended command the computer shuts down and never comes back on,Have you checked the BIOS option "Power on when AC Returns"? Does the UPS unit perform a delayed power off some time after the box shuts down? Roger
Seemingly Similar Threads
- testing shutdown: pc not restarting; and "ups unavailable" messages
- testing shutdown: pc not restarting; and "ups unavailable" messages
- testing shutdown: pc not restarting; and "ups unavailable" messages
- testing shutdown: pc not restarting; and "ups unavailable" messages
- testing shutdown: pc not restarting; and "ups unavailable" messages