Giovanni Panozzo
2013-Jun-11 18:23 UTC
[Nut-upsdev] [HCL] Atlantis Land A03-P551(V1.2) supported by <blazer_usb>
Atlantis Land A03-P551(V1.2) battery.charge: 100 battery.voltage: 13.70 battery.voltage.high: 13.00 battery.voltage.low: 10.40 battery.voltage.nominal: 12.0 device.mfr: device.model: device.type: ups driver.name: blazer_usb driver.parameter.langid_fix: 0x0409 driver.parameter.pollinterval: 2 driver.parameter.port: x driver.version: 2.6.4 driver.version.internal: 0.08 input.current.nominal: 0.0 input.frequency: 50.0 input.frequency.nominal: 50 input.voltage: 220.1 input.voltage.fault: 140.0 input.voltage.nominal: 220 output.voltage: 216.7 ups.beeper.status: enabled ups.delay.shutdown: 30 ups.delay.start: 180 ups.firmware: VT21071G ups.load: 10 ups.mfr: ups.model: ups.productid: 0000 ups.status: OL ups.temperature: 30.0 ups.type: offline / line interactive ups.vendorid: ffff *** Please note *** langid_fix = "0x0409" is mandatory, or you will get a lot of Communications with UPS lost: status read failed! Communications with UPS re-established in your syslog ----------------- Shutdown (and notification also) worked with a problem: nut is unable to turn off the load, so you are forced to power on manually your PCs when power is back. Also tried with UPS on battery and the following cmd upscmd -u admin -p mypwd myups load.off upscmd -u admin -p mypwd myups shutdown.return upscmd -u admin -p mypwd myups shutdown.stayoff all commands give "OK" as answer. But the load stays on. ------------------- This UPS model is quite old, maybe 3 or 4 years old. I think it was mainly sold in Italy. I can find it on the manufacturer website, but it's no longer available on online shops. Here is the user manual in italian, english, french, german and spanish: http://www.atlantisland.it/download/USERGUIDE/A03-P551%28701%29_MX01.pdf And here is the official page in italian http://www.atlantisland.it/pub/prodotti.php?famiglia=1&l1=7&l2=24&articolo=QTAzLVA1NTE=
Maybe Matching Threads
- No power cycle after shutdown on Atlantis Land OnePower A03-S1001
- No power cycle after shutdown on Atlantis Land OnePower A03-S1001
- No power cycle after shutdown on Atlantis Land OnePower A03-S1001
- No power cycle after shutdown on Atlantis Land OnePower A03-S1001
- No power cycle after shutdown on Atlantis Land OnePower A03-S1001