Hello! I have the APC SURT8000XL whith AP9619. I connect it to the NUT whith the snmp-ups driver, but have the error: "[SURT8000XL] Warning: excessive poll failures, limiting error reporting". The OS is FreeBSD 9.0. The APC SU5000I whith the AP9617 connecting to NUT - OK! ups.conf [SURT8000XL] ? ?driver = snmp-ups ? port = xxx.xxx.xxx.xxx ? ?community = public ? desc = "SURT8000XL" -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120427/e0d8d447/attachment.html>
Hi, first, please subscribe to the mailing list prior to any further mail: http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/nut-upsuser 2012/4/27 ??????? ??????? <mrtstv at mail.ru>> Hello! > I have the APC SURT8000XL whith AP9619. I connect it to the NUT whith the > snmp-ups driver, but have the error: "[SURT8000XL] Warning: excessive poll > failures, limiting error reporting". The OS is FreeBSD 9.0. > The APC SU5000I whith the AP9617 connecting to NUT - OK! > > ups.conf > [SURT8000XL] > driver = snmp-ups > port = xxx.xxx.xxx.xxx > community = public > desc = "SURT8000XL" >please send a compressed driver debug output, Ie: $ /path/to/snmp-ups -DDDDD -a SURT8000XL let it run for a couple of minutes before stopping it with Ctrl+C. cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr/ -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120427/2b0bc28e/attachment-0001.html>
Fri, 27 Apr 2012 10:24:38 +0200 ?? Arnaud Quette <aquette.dev at gmail.com>: Hi, first, please subscribe to the mailing list prior to any further mail: http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/nut-upsuser 2012/4/27 ??????? ??????? <mrtstv at mail.ru> Hello! I have the APC SURT8000XL whith AP9619. I connect it to the NUT whith the snmp-ups driver, but have the error: "[SURT8000XL] Warning: excessive poll failures, limiting error reporting". The OS is FreeBSD 9.0. The APC SU5000I whith the AP9617 connecting to NUT - OK! ups.conf [SURT8000XL] ? ?driver = snmp-ups ? port = xxx.xxx.xxx.xxx ? ?community = public ? desc = "SURT8000XL" please send a compressed driver debug output, Ie: $ /path/to/snmp-ups -DDDDD -a SURT8000XL let it run for a couple of minutes before stopping it with Ctrl+C. cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr/ The debug: snmp-ups -DDDDD -a SURT8000XL 12.257853 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.6.0 12.257856 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.1.0 12.257860 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.1.1.0 12.257863 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.4.0 12.257866 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.5.0 12.257869 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.7.0 12.257872 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.7.0 12.257876 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.7.2.2.0 12.257879 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.7.2.5.0 12.257882 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.7.2.5.0 12.257885 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.9.1.1.0 12.257892 send_to_all: SETINFO ups.status "OL" 12.259132 dstate_init: sock /var/db/nut/snmp-ups-SURT8000XL open on fd 5 12.259141 send_to_all: SETINFO driver.parameter.pollinterval "2" 12.259148 send_to_all: SETINFO device.mfr "APC" 12.259154 send_to_all: SETINFO device.model "Smart-UPS RT 8000 XL" 12.259160 send_to_all: SETINFO device.serial "IS0907001037" 12.259164 SNMP UPS driver : entering upsdrv_updateinfo() 14.259484 SNMP UPS driver : entering upsdrv_updateinfo() 16.260485 SNMP UPS driver : entering upsdrv_updateinfo() 18.261482 SNMP UPS driver : entering upsdrv_updateinfo() 20.262484 SNMP UPS driver : entering upsdrv_updateinfo() ^C 20.841080 Signal 2: exiting -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120427/69a04a65/attachment.html>
2012/4/27 ??????? ??????? <mrtstv at mail.ru>> > Fri, 27 Apr 2012 10:24:38 +0200 ?? Arnaud Quette <aquette.dev at gmail.com>: > > Hi, > > first, please subscribe to the mailing list prior to any further mail: > http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/nut-upsuser > > 2012/4/27 ??????? ??????? <mrtstv at mail.ru<http://e.mail.ru/cgi-bin/sentmsg?compose&To=mrtstv at mail.ru> > > > > Hello! > I have the APC SURT8000XL whith AP9619. I connect it to the NUT whith the > snmp-ups driver, but have the error: "[SURT8000XL] Warning: excessive poll > failures, limiting error reporting". The OS is FreeBSD 9.0. > The APC SU5000I whith the AP9617 connecting to NUT - OK! > > ups.conf > [SURT8000XL] > driver = snmp-ups > port = xxx.xxx.xxx.xxx > community = public > desc = "SURT8000XL" > > > please send a compressed driver debug output, Ie: > $ /path/to/snmp-ups -DDDDD -a SURT8000XL > > let it run for a couple of minutes before stopping it with Ctrl+C. > > cheers, > Arnaud > -- > Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com > Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ > Debian Developer - http://www.debian.org > Free Software Developer - http://arnaud.quette.free.fr/ > > The debug: snmp-ups -DDDDD -a SURT8000XL > > 12.257853 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.6.0 > 12.257856 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.1.0 > 12.257860 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.1.1.0 > 12.257863 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.4.0 > 12.257866 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.5.0 > 12.257869 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.7.0 > 12.257872 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.6.2.7.0 > 12.257876 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.7.2.2.0 > 12.257879 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.7.2.5.0 > 12.257882 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.7.2.5.0 > 12.257885 SU_CMD_MASK => .1.3.6.1.4.1.318.1.1.1.9.1.1.0 > 12.257892 send_to_all: SETINFO ups.status "OL" > 12.259132 dstate_init: sock /var/db/nut/snmp-ups-SURT8000XL open on fd 5 > 12.259141 send_to_all: SETINFO driver.parameter.pollinterval "2" > 12.259148 send_to_all: SETINFO device.mfr "APC" > 12.259154 send_to_all: SETINFO device.model "Smart-UPS RT 8000 XL" > 12.259160 send_to_all: SETINFO device.serial "IS0907001037" > 12.259164 SNMP UPS driver : entering upsdrv_updateinfo() > 14.259484 SNMP UPS driver : entering upsdrv_updateinfo() > 16.260485 SNMP UPS driver : entering upsdrv_updateinfo() > 18.261482 SNMP UPS driver : entering upsdrv_updateinfo() > 20.262484 SNMP UPS driver : entering upsdrv_updateinfo() > ^C 20.841080 Signal 2: exiting > > I really need the complete trace of the first 2 minutes.you trimmed the above to 8 seconds, between 12 and 20, which is not sufficient... I also need an upsc output. cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr/ -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120502/45aa95ed/attachment.html>