On Wed, Jan 10, 2007 at 05:41:50PM +1100, Ben Dinnerville
wrote:> Hi All,
>
> I am trying to tune out some echo on a analogue line and have run
> ztmonitor to get some info. When i run it, i get a RX reading when the
> line is idle - is this normal? eg:
>
> [root@004063E4ECBC zaptel-1.2.10]# ./ztmonitor 1 -vv
>
> Visual Audio Levels.
> --------------------
> Use zapata.conf file to adjust the gains if needed.
>
> ( # = Audio Level * = Max Audio Hit )
> <----------------(RX)---------------->
> <----------------(TX)---------------->
>
> Rx: 132 ( 132) Tx: 0 ( 0)
>
> This happens on all 4 lines with varying rx levels
When the line is on-hook, its sample values are basically meaningless, I
gather.
--
Tzafrir Cohen
icq#16849755 jabber:tzafrir@jabber.org
+972-50-7952406 mailto:tzafrir.cohen@xorcom.com
http://www.xorcom.com iax:guest@local.xorcom.com/tzafrir