Igor Vlasenko
2019-Aug-22 07:57 UTC
[Nut-upsdev] RUCELF__UPI-1000-12-E: confirmation and .dev for Devices Dumps Library
I have successfully connected UPS RUCELF UPI-1000-12-EL to NUT, and would like to contribute .dev file for this model to NUT's Devices Dumps Library. file is attached to the mail, I also added a copy below: # --- Rucelf__UPI-1000-12-EL__blazer_usb__2.7.4__01.dev -- battery.charge: 100 battery.packs: 6 #COMMENT: added manually to fix battery.voltage (was: 2.22), see ups.conf below battery.voltage: 13.32 battery.voltage.high: 13 #COMMENT: added manually, see ups.conf below battery.voltage.low: 10.4 #COMMENT: added manually, see ups.conf below battery.voltage.nominal: 12.0 #COMMENT: added manually, see ups.conf below device.mfr: device.model: device.type: ups driver.name: blazer_usb driver.parameter.langid_fix: 0x409 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0000 driver.parameter.synchronous: no driver.parameter.vendorid: 0001 driver.version: 2.7.4 driver.version.internal: 0.12 input.current.nominal: 10.0 input.frequency: 50.0 input.frequency.nominal: 50 input.voltage: 220.0 input.voltage.nominal: 220 output.voltage: 220.0 ups.beeper.status: disabled ups.delay.shutdown: 30 ups.delay.start: 180 ups.firmware: USB:1.00 ups.load: 0 ups.mfr: ups.model: ups.productid: 0000 ups.status: OL ups.temperature: 42.0 ups.type: online ups.vendorid: 0001 #CMD:load.off #CMD:load.on #CMD:shutdown.return #CMD:shutdown.stayoff #CMD:shutdown.stop #CMD:test.battery.start #CMD:test.battery.start.deep #CMD:test.battery.start.quick #CMD:test.battery.stop # ---- # no variables, upsrw returns empty list # ---- # 100A/h external battery is connected in this dump. # ---- #tail -12 /etc/nut/ups.conf #[rucelf] # driver = blazer_usb # langid_fix = 0x409 # port = auto # vendorid = 0001 # productid = 0000 # desc = "RUCELF UPI-1000-12-EL" # override.battery.packs = 6 # default.battery.voltage.nominal = 12 # default.battery.voltage.low = 10.4 # default.battery.voltage.high = 13 # ---- -- I V -------------- next part -------------- battery.charge: 100 battery.packs: 6 #COMMENT: added manually to fix battery.voltage (was: 2.22), see ups.conf below battery.voltage: 13.32 battery.voltage.high: 13 #COMMENT: added manually, see ups.conf below battery.voltage.low: 10.4 #COMMENT: added manually, see ups.conf below battery.voltage.nominal: 12.0 #COMMENT: added manually, see ups.conf below device.mfr: device.model: device.type: ups driver.name: blazer_usb driver.parameter.langid_fix: 0x409 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0000 driver.parameter.synchronous: no driver.parameter.vendorid: 0001 driver.version: 2.7.4 driver.version.internal: 0.12 input.current.nominal: 10.0 input.frequency: 50.0 input.frequency.nominal: 50 input.voltage: 220.0 input.voltage.nominal: 220 output.voltage: 220.0 ups.beeper.status: disabled ups.delay.shutdown: 30 ups.delay.start: 180 ups.firmware: USB:1.00 ups.load: 0 ups.mfr: ups.model: ups.productid: 0000 ups.status: OL ups.temperature: 42.0 ups.type: online ups.vendorid: 0001 #CMD:load.off #CMD:load.on #CMD:shutdown.return #CMD:shutdown.stayoff #CMD:shutdown.stop #CMD:test.battery.start #CMD:test.battery.start.deep #CMD:test.battery.start.quick #CMD:test.battery.stop # ---- # no variables, upsrw returns empty list # ---- # 100A/h external battery is connected in this dump. # ---- #tail -12 /etc/nut/ups.conf #[rucelf] # driver = blazer_usb # langid_fix = 0x409 # port = auto # vendorid = 0001 # productid = 0000 # desc = "RUCELF UPI-1000-12-EL" # override.battery.packs = 6 # default.battery.voltage.nominal = 12 # default.battery.voltage.low = 10.4 # default.battery.voltage.high = 13 # ----