Pascal MIRALLES
2012-Jul-13 09:23 UTC
[Nut-upsdev] [HCL] UNITEK Alpha650ipF supported by blazer_usb
UNITEK Alpha650ipF and Alpha650ipE Build NUT v2.6.4 from sources http://www.networkupstools.org/source/2.6/nut-2.6.4.tar.gz System: RedHat Linux RHEL4 Kernel: 2.6.9-42.0.10.EL (upsc) command output : battery.charge: 100 battery.voltage: 14.30 battery.voltage.high: 13.00 battery.voltage.low: 10.40 battery.voltage.nominal: 12.0 device.mfr: UNITEK device.model: Alph650ipF device.type: ups driver.name: blazer_usb driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0001 driver.parameter.vendorid: 0f03 driver.version: 2.6.4 driver.version.internal: 0.08 input.current.nominal: 2.8 input.frequency: 60.0 input.frequency.nominal: 50 input.voltage: 121.3 input.voltage.fault: 121.3 input.voltage.nominal: 230 output.voltage: 202.0 ups.beeper.status: disabled ups.delay.shutdown: 30 ups.delay.start: 180 ups.firmware: A0 ups.load: 33 ups.mfr: UNITEK ups.model: Alph650ipF ups.productid: 0001 ups.status: OL ups.temperature: 32.0 ups.type: offline / line interactive ups.vendorid: 0f03 (upscmd -l) command output : Instant commands supported on UPS [unitek650ipF]: beeper.toggle - Toggle the UPS beeper load.off - Turn off the load immediately load.on - Turn on the load immediately shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off shutdown.stop - Stop a shutdown in progress test.battery.start - Start a battery test test.battery.start.deep - Start a deep battery test test.battery.start.quick - Start a quick battery test test.battery.stop - Stop the battery test I haven't tested shutdown command yet but the device is detected. Just one question : Why there are no packages nut-2.4 and nut-2.6 for RedHat RHEL4 and RHEL5 ? Thanks. Pamidou -- ___________________________________________ Le Site de Pascal http://www.pamidou.net
Ivan Kuznetsov
2012-Jul-13 10:38 UTC
[Nut-upsdev] [HCL] UNITEK Alpha650ipF supported by blazer_usb
Hello 13.07.2012 13:23, Pascal MIRALLES ?????:> UNITEK Alpha650ipF and Alpha650ipE > Build NUT v2.6.4 from sources > http://www.networkupstools.org/source/2.6/nut-2.6.4.tar.gz > System: RedHat Linux RHEL4 > Kernel: 2.6.9-42.0.10.EL> Just one question : Why there are no packages nut-2.4 and nut-2.6 for > RedHat RHEL4 and RHEL5 ?I have building RPMS for nut 2.6.x for EL4 and EL5. Theese distros are to old (especially EL4) to compile nut with full feature set. E.g. no hal and avahi in EL4, incompatible version of freeipmi in EL5 and so on. Also there are some quirks in automake files and init scripts need to be fixed. I can share my nut-2.6.4-2.el4.src.rpm and nut-2.6.4-2.el5.src.rpm if you are interested in -- Regards, Ivan Kuznetsov SOLVO ltd
Arnaud Quette
2012-Jul-16 18:01 UTC
[Nut-upsdev] [HCL] UNITEK Alpha650ipF supported by blazer_usb
Bonjour Pascal 2012/7/13 Pascal MIRALLES <pascal at pamidou.net>> UNITEK Alpha650ipF and Alpha650ipE > Build NUT v2.6.4 from sources > http://www.networkupstools.org/source/2.6/nut-2.6.4.tar.gz > System: RedHat Linux RHEL4 > Kernel: 2.6.9-42.0.10.EL > > (upsc) command output : > battery.charge: 100 > battery.voltage: 14.30 > battery.voltage.high: 13.00 > battery.voltage.low: 10.40 > battery.voltage.nominal: 12.0 > device.mfr: UNITEK > device.model: Alph650ipF > device.type: ups > driver.name: blazer_usb > driver.parameter.pollinterval: 2 > driver.parameter.port: auto > driver.parameter.productid: 0001 > driver.parameter.vendorid: 0f03 > driver.version: 2.6.4 > driver.version.internal: 0.08 > input.current.nominal: 2.8 > input.frequency: 60.0 > input.frequency.nominal: 50 > input.voltage: 121.3 > input.voltage.fault: 121.3 > input.voltage.nominal: 230 > output.voltage: 202.0 > ups.beeper.status: disabled > ups.delay.shutdown: 30 > ups.delay.start: 180 > ups.firmware: A0 > ups.load: 33 > ups.mfr: UNITEK > ups.model: Alph650ipF > ups.productid: 0001 > ups.status: OL > ups.temperature: 32.0 > ups.type: offline / line interactive > ups.vendorid: 0f03 > > (upscmd -l) command output : > Instant commands supported on UPS [unitek650ipF]: > > beeper.toggle - Toggle the UPS beeper > load.off - Turn off the load immediately > load.on - Turn on the load immediately > shutdown.return - Turn off the load and return when power is back > shutdown.stayoff - Turn off the load and remain off > shutdown.stop - Stop a shutdown in progress > test.battery.start - Start a battery test > test.battery.start.deep - Start a deep battery test > test.battery.start.quick - Start a quick battery test > test.battery.stop - Stop the battery test > > I haven't tested shutdown command yet but the device is detected. >please test the shutdown, since it's the very basic feature that must work! you may want to use the documentation to drive you: http://www.networkupstools.org/docs/user-manual.chunked/ar01s06.html#Testing_shutdowns I'll wait for your feedback on the device shutdown before committing entries in the HCL. Thanks for your report. cheers, Arno -- Linux / Unix / Opensource Engineering Expert - Eaton - http://opensource.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20120716/f16d6615/attachment.html>