We have a cluster (212 nodes) that are on a gig-e network useing jumbo frames (mtu 6000) To reload a node we have to plug it into a regular 1500 mtu that is running off a differnt port on the head node to install. Is there a way to tell in the 'append' line of /pxelinux.cfg/default to have the bcm5700 module run wiht jumbo frames. this is our append right now append load_ramdisk=1 initrd=sles-8/initrd.node Insmod=bcm5700 Install=nfs://141.212.31.100/home/opt/atipa/sles-8/ Netdevice=eth1 autoyast=nfs://141.212.31.100//home/opt/atipa/sles-8/profiles/node.xm and our modules.conf to make the nic work with the gig network requires this options bcm5700 mtu=9000,1500 line_speed=1000,1000 auto_speed=0,0 full_duplex=1,1 Thanks for help Brock Palen http://cac.engin.umich.edu __________________________________________________ www.palen.serveftp.net www.umsolar.com brockp at umich.edu