Displaying 20 results from an estimated 110 matches similar to: "SKE UPS 1500VA/900W"
2024 Sep 25
2
SKE UPS 1500VA/900W
Hello,
Not really sure. Have not heard about such a brand/model on one hand, and
the Home Assistant NUT plugin may be (or not be) limiting the selection of
data points it shows from NUT on the other.
Can you query the readings with NUT `upsc` client?
Also, `nutdrv_qx` is an umbrella driver for many different dialects of
"Megatec Q<x>" protocol family. Check the
2024 Sep 25
1
SKE UPS 1500VA/900W
I believe the integration is presented as a container on the HA server, so
there should be a way to log into it and edit `/etc/nut/ups.conf` or
similar during the experiments (generated from YAML settings made in HA GUI
somewhere). I have not used it directly, so I can't really help more here.
Jim
On Wed, Sep 25, 2024 at 5:47?PM Daniele Lamaddalena <dlamaddalena at gmail.com>
wrote:
2024 Mar 27
1
Je ne parviens pas à faire communiquer mon UPS avec HomeAssistant
Bonjour ? tous,
Je n'arrive pas a faire marcher NUT avec HomeAssistant.
Cela fait des mois que je suis la-dessus, mais sans succ?s !
Je ne vois plus quoi faire ! Help !
*
Ubuntu 23.10
*
NUT version = 2.7.4-14ubuntu2
*
NUT installation method: Package
*
exact device name and related information : Riello IDG800
Voici les commandes que je tape sur le PC connect?
2020 Aug 06
3
RISC-V LLVM Sync Up - 6 Aug 2020
For background on these calls, see
<http://lists.llvm.org/pipermail/llvm-dev/2019-September/135087.html>.
Reminder: the purpose is to co-ordinate between active contributors.
If you have support questions etc then it's best to post to llvm-dev.
We have a call every alternate Thursday at 4pm BST, via
<https://meet.google.com/ske-zcog-spp>.
We have created a shared calendar which
2020 Mar 19
3
RISC-V LLVM sync-up call 19 Mar 2020
For background on these calls, see
<http://lists.llvm.org/pipermail/llvm-dev/2019-September/135087.html>.
Reminder: the purpose is to co-ordinate between active contributors.
If you have support questions etc then it's best to post to llvm-dev.
We have a call each Thursday at 4pm GMT, via
<https://meet.google.com/ske-zcog-spp>.
I've created a shared calendar which may help
2018 Jan 24
1
random sample set for regression
Hi,
I'm not a programmer, so I have a question about R functions,
I run the Random Forest regression models, but
I would like to run the random forest model 1000 times with different
random sample set. to check the uncertainty of the regression model
estimates.
exemple of data:
#################################
table= all
Y: all$AGB
X variables:
Variables=as.matrix(all[, c( "min",
2020 Nov 12
1
RISC-V LLVM sync-up call 12 November 2020
For background on these calls, see
<http://lists.llvm.org/pipermail/llvm-dev/2019-September/135087.html>.
Reminder: the purpose is to co-ordinate between active contributors.
If you have support questions etc then it's best to post to llvm-dev.
We have a call every alternate Thursday at 4pm GMT, via
<https://meet.google.com/ske-zcog-spp>.
We have a shared calendar which may help
2020 Mar 20
2
RISC-V LLVM sync-up call 19 Mar 2020
If I’m following correctly, there are two size-limited areas. One area, limited to 2GB, is the “text” area. This contains all the code. Then there’s a “global” area, limited to 4GB, which is pointed to by the global pointer. This contains the GOT, plus a flexible area that the object file can stick small bits of data into. And then outside of both of those, additional data is unlimited.
It
2020 Mar 23
2
RISC-V LLVM sync-up call 19 Mar 2020
Hi, Sam.
I think that it's a fair comparison.
Keep in mind that the GP is only used to reach global variables of local scope and the GOT, where the address of global variables of global scope reside.
This model assumes that the distance between the GP and the global data area, GOT and local scope variables is defined at link time.
__
Evandro Menezes ◊ SiFive ◊ Austin, TX
> On Mar
2024 Sep 11
1
[PATCH v2 3/3] drm/nouveau: Add drm_panic support for nv50+
On Wed, Sep 11, 2024 at 10:19?AM Jocelyn Falempe <jfalempe at redhat.com>
wrote:
> On 06/09/2024 21:36, James Jones wrote:
> > Right, there are 3 iterations of block linear tiling actually. NV50 does
> > support scanout of block linear surfaces. All block-linear-capable GPUs
> > do. The 3 generations are:
> >
> > NV5x/G8x/GTXXX line: Original block size.
2020 Mar 20
2
RISC-V LLVM sync-up call 19 Mar 2020
Oh, I wasn’t really thinking about devices without an MMU where the addresses are physically separated. Makes sense.
This reminds me of rwpi on ARM; it has a sort of similar scheme of referring to data indirectly through a pointer, but it also changes the ABI to keep the pointer in a reserved register.
-Eli
From: Evandro Menezes <evandro.menezes at sifive.com>
Sent: Friday, March 20, 2020
2014 Sep 05
0
Smart1500lcdt will not connect with usbhid-ups KSTAR BM3150 1500VA "Line Interactive" High Frequency UPS
Barry,
I have had success with NUT on Debian and an EATON 5E2000IUSB-AU 5E
2000VA/1200W UPS With 3 x OUTLETS which I believe is good value.
I would believe the the EATON ?5E 1500VA/900W UPS With 3 x OUTLETS
would work just as well.
The 1500VA also uses the same batteries as the 2000VA so I would
believe it would run its raited load longer than 2000VA. My eight
drive RAID driver uses less that
2010 Oct 13
1
sweex UPS 1500VA
Hello,
have some of you tried sweex UPS 1500VA
(http://www.sweex.com/en/assortiment/power-security/power-protection/PP220).
It is not listed in hardware compatibility list.
As I can see, sweex can be problematic with drivers, but it is not possible to
change this UPS to other model now.
It is connected by USB and lsusb says only:
Bus 002 Device 004: ID 0665:5161 Cypress Semiconductor USB to
2010 Apr 15
1
Noob Question : Compatibility between NUT and an APC BACK-UPS RS 1500VA 230V
Hi,
It's the first time that we want to use an UPS in our labo. We have 1
server, which are running under an old version of opensuse. We would
like to use the stable tree of nut on the computer with an APC BACK-UPS
RS 1500VA 230V. I have seen on the compatibility page, that this UPS is
supported. is there anyone, who uses this UPS with NUT to confirm that ?
Thanks a lot,
Best regards,
GiGGz
2016 Sep 14
0
nutdrv-qx powercool 1500VA USB UPS
On Wed, Aug 31, 2016 at 4:19 AM, Matthew Wire <mjw at mjwconsult.co.uk> wrote:
> Further analysis it looks like the status string matches the q1 subdriver
> but a lowercase "f" is sent to request it instead of "Q1\r". What do you
> think?
It is certainly possible - there is no comprehensive protocol guide
for all these variants.
I was hoping we would hear from
2016 Oct 03
0
nutdrv-qx powercool 1500VA USB UPS
Hi, it does communicate using the fabula subdriver but I don't get any of
the values parsed. If I execute:
./nutdrv_qx -a powercool -DDDDD -x subdriver=fabula -x vendorid=0001 -x
productid=0000
I get the following returned:
12.242991 upsdrv_updateinfo...
12.243047 Quick update...
12.243069 send: Q1
12.243087 command index: 0x03
12.249983 read: (47 bytes) => 28 30 30 30 2e 30 20
2016 Oct 10
0
nutdrv-qx powercool 1500VA USB UPS
> On Oct 10, 2016, at 4:29 PM, Matthew Wire <mjw at mjwconsult.co.uk> wrote:
>
> Here is the complete log for two minutes from startup. thank you
compressed to fit on the mailing list.
>
> On 9 October 2016 at 23:41, hyouko at gmail.com <hyouko at gmail.com> wrote:
> > 12.243069 send: Q1
> > 12.243087 command index: 0x03
> > 12.249983 read: (47
2016 Oct 16
3
nutdrv-qx powercool 1500VA USB UPS
Thanks for the log - apparently we always get valid (apart from
0.191312) but empty replies, not only for index 0x03, but also for the
other queried index (0x0c).
I've re-looked at the logs you posted on GitHub, but I don't see
anything exotic going on there.
Maybe we're missing some sort of handshaking or the like: can you post
the whole captures/logs, right from when you plug the
2016 Nov 03
0
nutdrv-qx powercool 1500VA USB UPS
Hi Charles,
I've added 3 more files to github.
https://github.com/mattwire/powercool-ups/blob/master/wireshark-UPSmart-startup.pcapng
- captures startup of UPSmart software and continues for about 5 minutes.
https://github.com/mattwire/powercool-ups/blob/master/wireshark-UPSmart-ups_off-on.pcapng
- UPSmart software is running, UPS is OFF. UPS is switched on and connects
to software.
2016 Nov 04
1
nutdrv-qx powercool 1500VA USB UPS
Wow just seen this screenshot. I did not know it did that. Is this the
port is ask for? Can I go to it's webpage and some port to see this type
screen?
-Raymond Day
On 11/3/2016 6:39 PM, Matthew Wire wrote:
> https://github.com/mattwire/powercool-ups/blob/master/UPSmart_connected.png
> - is a screenshot of the UPSmart software when connected (shows some
> values from UPS).