Controlling Different Loads using NUT
Hello,
I was setting up a TrippLite UPS more specifically the SMART1000RMXL2U
model and the way I have it set up is I have a network switch plugged into
one load and the PC plugged into another load on this UPS model. Is there
any way I can configure the UPS using NUT to have the load containing the
PC to delay its boot up by 10 minutes for example to allow the other load
to turn on before it?
2023 Apr 05
0
controlling loads using NUT
Hello,
I was setting up a TrippLite UPS more specifically the SMART1000RMXL2U
model and the way I have it set up is I have a network switch plugged into
one load and the PC plugged into another load on this UPS model. Is there
any way I can configure the UPS using NUT to have the load containing the
PC to delay its boot up by 10 minutes for example to allow the other load
to turn on before it?
2023 Apr 06
0
Controlling which loads come on after a power outage using NUT
Hi,
I have a SMART1000RMXL2U TrippLite and have issues with the power coming
back on during the shutdown as one of the loads are turning on too quickly
causing a configuration switch on the other load to not boot on in time.
The way I have it set up is I have a network switch plugged into one load
and the PC plugged into another load on this UPS model. Is there any way I
can configure the UPS
2020 Jul 22
3
AVRX750/500 issues
Thanks for chiming in @David Zomaya. Tripp Lite replaced my AVRX550U once thinking that the powering back on was a defective unit, but the replacement does the same thing. The SN on the first one is 2935AVHOM87BB00152. NUT has my model listed as protocol 2010, so that needs to be corrected to 2012, but I'm not sure if anyone is doing active development on it right now.
I also have a
2020 Jul 22
1
AVRX750/500 issues
I wouldn't be surprised if they both use the same driver. I think they are essentially the same model, but with one having a slightly larger battery. My issue is primarily with the UPS turning back on after having shut off like it should. @Scott Colby if you take a look at the config files I posted in the github issue I created, perhaps that will give you some hints on your issue. Maybe
2020 May 21
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
I'm not seeing this in the log. I'm guessing that's not great.
May 20 19:57:28 elmer upsmon[3828]: Poll UPS [tripplite at localhost] failed - Data stale
May 20 19:57:33 elmer upsmon[3828]: Poll UPS [tripplite at localhost] failed - Data stale
May 20 19:57:38 elmer upsmon[3828]: Poll UPS [tripplite at localhost] failed - Data stale
May 20 19:57:43 elmer upsmon[3828]: Poll UPS
2020 May 21
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
David,
Thanks again for your help today. You're amazing.
If the folks on the list could chime in - thoughts about what I could try next?
May 20 19:57:28 elmer upsmon[3828]: Poll UPS [tripplite at localhost] failed - Data stale
pi at elmer:/home/macbackup $ lsusb
Bus 002 Device 006: ID 0bc2:3343 Seagate RSS LLC
Bus 002 Device 005: ID 0bc2:3343 Seagate RSS LLC
Bus 002 Device
2020 May 20
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
Sorry, neglected to mention:
You'll need to either reload the udev rules or reboot to make the new rule "active".
Thank you,
David Zomaya
Tripp Lite
________________________________
From: David Zomaya
Sent: Wednesday, May 20, 2020 2:11:24 PM
To: Tom Cooper
Cc: nut-upsuser
Subject: Re: [POSSIBLE FRAUD] Re: [Nut-upsuser] [EXTERNAL] Re: Help with Tripp Lite Internet600U
2020 May 20
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
The fix:
Was following a howto here: https://raymondjdouglas.com/blog/2018/ups-monitoring/
Much thanks to David Zomaya for coming up with the recipe!
Nut.conf:
Just have
MODE=standalone
UPS.conf
[tripplite]
driver = usbhid-ups
port = auto
productid=3024
desc = "Tripp Lite Internet600U"
upsd.conf
LISTEN 127.0.0.1 3493
LISTEN ::1 3493
2020 May 21
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
No, it's not.
I'd defer to the list for tips on that one.
First thing I'd try if no one else has ideas is checking lsusb and restarting the service.
Thank you,
David Zomaya
Tripp Lite<http://www.tripplite.com/>
________________________________
From: Tom Cooper <tom at cooperfamily.xyz>
Sent: Wednesday, May 20, 2020 7:00 PM
To: David Zomaya
Cc: nut-upsuser
2020 May 20
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
Funny - I thought of that and had tried it. Didn't work
I also moved it from the USB2 ports to the USB3 ports.
Same result.
I have not heard of udev, but after quick googling and glancing at an example, /etc/udev/rules.d/99-com.rules
I am not convinced that I coule come up with a formula to make a working rule.
Is there a simple sample I can copy to help figure out elevated
2020 May 20
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
David,
I appreciate the quick feedback!
If I didn't fat finger any of the parameters you sent me, it's still not working.
Here's the output from the attempt to start. (BTW - nothing appears in the daemon.log when I use the upsdrvctl command.)
pi at elmer:/home/macbackup $ sudo vi /etc/nut/nut.conf
pi at elmer:/home/macbackup $ sudo vi /etc/nut/ups.conf
pi at
2020 May 20
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
David,
That's exciting - but I am not seeing similar results.
I *must* be doing something dumb - but I can't see it.
I've got nut-2.7.4-8 installed on my pi
Hope you can help.
Tom
pi at elmer:/home/macbackup $ lsusb | grep ipp
Bus 001 Device 004: ID 09ae:3024 Tripp Lite
pi at elmer:/home/macbackup $ sudo cat /etc/nut/nut.conf
# Network UPS Tools: example nut.conf
#
2020 Jan 04
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Hi Jean-Roch,
No. There is no user-facing firmware update process available.
If there are any particular commands you're interested in on a newer unit, I can look them up.
________________________________
From: jean-roch blais <blaisjeanroch at gmail.com>
Sent: Friday, January 3, 2020 6:13 PM
To: David Zomaya
Cc: nut-upsuser at alioth-lists.debian.net
Subject: Re: [POSSIBLE FRAUD] Re:
2016 Oct 20
2
TrippLite SU3000XLCD
I'm having trouble with a TrippLite SU3000XLCD. I'm using a Raspberry Pi running Raspbian (wheezy) with NUT 2.6.4.
I can monitor my older TrippLite UPSs, mostly SU1000RT2Us, with this Pi and a USB to serial adapter.
My first thought with the SU3000XLCD was to use the USB port instead of the serial port as that's the "modern" thing to do. When I plugged the USB cable in
2019 Jun 24
0
[EXTERNAL] Re: Fixing Drops With SMART1500LCDXL & USB-HID Driver
Updates on this:
1) Making progress in the related Dev list thread here: https://alioth-lists.debian.net/pipermail/nut-upsdev/2019-June/007440.html
I’ll keep that thread up to date with progress as I go. But if there are specific things it would make sense to test here, just let me know. Otherwise, I figure reducing redundancy makes sense?
2) I tried disabling usbcore.autosuspend, but
2020 May 20
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
Glad to hear it's working, thanks Tom.
Network UPS Tools team: is fixing this as simple as me telling you what new UPS protocols are HID-PDC compliant?
Thank you,
David Zomaya
Tripp Lite<http://www.tripplite.com/>
________________________________
From: Tom Cooper <tom at cooperfamily.xyz>
Sent: Wednesday, May 20, 2020 2:42 PM
To: David Zomaya
Cc: nut-upsuser
Subject: Re:
2020 Jan 04
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Ok thank's for your time David, the PSUs, I have two old ones, are working
very well. I simply put in new batteries and on they go :-). I'm using the
PSUs mostly to secure my Raspberry PIs, which are notorious to fail (SD
card) on power failures. Bye, jrb.
On Fri, Jan 3, 2020 at 7:35 PM David Zomaya <David_Zomaya at tripplite.com>
wrote:
>
> Hi Jean-Roch,
> No. There is no
2020 Jan 04
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Thank's David, really appreciate your answer, and your time. Just a yes or
a no, can I upgrade the firmware on this UPS ?
Cheers
jrb
On Fri, Jan 3, 2020, 19:06 David Zomaya, <David_Zomaya at tripplite.com> wrote:
>
> After a quick glance, it looks like that older version of the INTERNET750U
> supports only a few controls Shutdown of the inverter, cancelling that
>
2020 May 20
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Re: Help with Tripp Lite Internet600U
Borrowing from our friends at Ask Ubuntu ( https://askubuntu.com/a/276637 ) there is. I've modified it for use with a Tripp Lite UPS and 3024 protocol below. Try disconnect/reconnect after and see what happens.
:/etc/nut$ cat /etc/udev/rules.d/90-nut-ups.rules
# /etc/udev/rules.d/90-nut-ups.rules
ACTION=="add", \
SUBSYSTEM=="usb", \
ATTR{idVendor}=="09ae",