similar to: upsd "events"

Displaying 20 results from an estimated 7000 matches similar to: "upsd "events""

2020 Nov 07
1
upsd "events"
On Sat, Nov 7, 2020 at 1:27 PM Charles Lepple <clepple at gmail.com> wrote: > On Nov 7, 2020, at 11:18 AM, Jason Antman <jason at jasonantman.com> wrote: > > > Hello, > > I'm quite new to NUT, currently setting it up on a few machines in my home > lab because I switched from an APC UPS to a CyberPower unit. This is > running in a home lab, and I'm
2020 Nov 07
0
upsd "events"
On Nov 7, 2020, at 11:18 AM, Jason Antman <jason at jasonantman.com> wrote: > > Hello, > > I'm quite new to NUT, currently setting it up on a few machines in my home lab because I switched from an APC UPS to a CyberPower unit. This is running in a home lab, and I'm trying to implement some apparently unusual logic around load-shedding. The interesting thing to me is
2020 Jun 22
2
Runtime testing
So, a while back I got around to ordering replacement batteries for my CyberPower PR3000LCDRTXL2U. When they arrived, I went to swap them in. I was horrified at the flimsiness of CyberPower's battery "trays". I've seen heavier gauge plastic on "blister" packages in the store. I ALSO discovered that the expansion unit had been shipped to me with one of its two
2019 Dec 16
3
Shutdown time configuration
On 2019-12-16 05:34, Roger Price wrote: > On Sun, 15 Dec 2019, Phil Stracchino wrote: > >> I switched a while back to a Cyberpower PR3000LCDRTXL2U UPS with an >> external battery chassis. We've lost power twice since I installed it, >> and both times, the UPS has killed power to everything while still >> indicating 80% capacity before NUT has even initiated
2009 Jun 10
2
Moving to new puppetmaster - certificates
Unfortunately I haven''t been able to find anything in the docs... I just built a new puppetmaster to replace my testing install on an old box. The hostname is different, and obviously the master certificates are different. What needs to be done to the clients to get them to play nice with the new box? Thanks, Jason Antman --~--~---------~--~----~------------~-------~--~----~ You
2024 Feb 21
1
System keeps going into FSD mode after power on
Hello, I am a new user of NUT and trying to wrap my ahead around a couple of things. I installed NUT 2.7.4-13 from package on RasPi 4, running Raspbian Linux 11 (bullseye). I have Cyberpower SL700U connected to it. For testing I set battery.charge.low to 90, so I wouldn't have to wait a long time. See all relevant config below. First of all, what seems to happen is that UPS gets to the low
2006 Feb 14
3
Master privileges unavailable on UPS
Hello all, I'm having problems with what I'm told should be a straightforward issue. The message in /var/log/daemon is: <quote> Feb 13 10:37:57 lupin upsmon[31324]: Master privileges unavailable on UPS [lupin1500AVR@localhost]
2017 Nov 10
2
Cyberpower PR2200ELCDRT2U
Dear Charles, thanks for your quick answer and your information! I didn't know there is a difference in the PR-series between old and new. So thanks for this valuable information! usbconfig dump_device_desc shows: ugen0.2: <CyberPower Systems product 0x0601> at usbus0, cfg=0 md=HOST spd=LOW (1.5Mbps) pwr=ON (50mA)
2019 Mar 30
2
upssched Not Running
2020 Aug 12
3
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
Hi everyone, Well, we lost power here again.  I was not at home, but I guess a dump truck smashed into some power poles and took out half the city; actually tripped most of the breakers in the panel.  Anyways, the power was out for just a few seconds and of course my servers shutdown on me after power being out for just a second or two.  Here is my syslog from two different machines.  I included
2019 May 25
2
Low Battery False Alarms
2009 Dec 02
5
Timers fireing too early
Hi all, I've not been able to find the answer to my timer problem in the faq or the archives. (or google) Basically, I can't get timers to fire. They fire ignoring the timer value, as if the timer was set to 0. I'm using the OpenFiler distribution, patched to the latest and greatest. upsmon 2.2.2 When I pull the power plug, I see the text "Im In Battery" instantly, instead
2016 Nov 23
2
[HCL] CyberPower Cyber Power Systems CP685AVR supported by usbhid-ups
It looks like the CyberPower Cyber Power Systems CP685AVR supported by usbhid-ups has a favorable device dump linked to the Devices Dumps Library page here: http://networkupstools.org/ddl/Cyber_Power_Systems/CP685AVR.html However, it is not listed anywhere on the Hardware Compatibility List (HCL) page here: http://networkupstools.org/stable-hcl.html This appears to be an omission on the HCL
2016 Aug 05
1
NUT UPS Slave Not Shutting Down
Hello All, I'm trying to establish a MASTER SLAVE configuration of UPS using NUT Driver. I'm able to shutdown the master after UPS is on BATTERY ( POWER BLACKOUT) .However I'm trying to shutdown the other SLAVE MACHINES BEFORE MASTER. But at the remote side ( Slaves ) shutdown after UPS blackout does not happen. My configuration in Master are /usr/etc/upsd.users
2015 Apr 27
3
upssched setup
Hi, I am unable to get upssched working correctly as my UPS calls low battery too late and there is no way to change it. I am running Nut 2.7.3 on Ubuntu 14.04 I have made this script, called /sbin/upssched-cmd.sh #!/bin/sh case $1 in onbatt) /sbin/upsmon -c fsd;; *) echo "shutdown implemented";; esac I am trying to run the script manually to break down my issues. All that
2011 Jun 08
2
Misconfiguration of Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port
Hello. I've tried to configure Windows (complete port, Beta): Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port but have no luck. Here is my config files: *nut.conf:* MODE = netserver *ups.conf:* [PW5115] driver = bcmxcp_usb port = notUsed desc = "PowerWare 5115" *upsd.conf:* LISTEN 192.168.1.12 3493 *upsd.users:* [monuser]
2012 Jan 04
3
NUT Windows port questions
An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120104/34be491b/attachment.html>
2017 Nov 10
3
Cyberpower PR2200ELCDRT2U
Hey guys, :) recently, I installed Cyberpower PR2200ELCDRT2U, however, I have not managed to get this UPS working with FreeNAS 11, yet. According to compatibility list, PR2200 should work fine, when using powerpanel driver: http://networkupstools.org/ddl/Cyber_Power_Systems/ http://networkupstools.org/ddl/Cyber_Power_Systems/PR2200.html However, when trying to establish a connection between
2015 Apr 27
3
upssched setup
Hi Roger, I get: Apr 27 20:50:05 unifi upsmon[1022]: UPS ups on batteryApr 27 20:50:05 unifi upssched[2688]: Timer daemon startedApr 27 20:50:06 unifi upssched[2688]: New timer: onbatt (20 seconds)Apr 27 20:50:26 unifi upssched[2688]: Event: onbattApr 27 20:50:26 unifi upssched[2688]: exec_cmd(/sbin/upssched-cmd.sh onbatt) returned 126Apr 27 20:50:41 unifi upssched[2688]: Timer queue empty,
2017 Jun 09
2
Apple Mac slave
On Thu, 8 Jun 2017, Robbie van der Walle wrote: > After the first test and the NAS is restarted I had to change the > setting battery.charge.low again to 80? Does the NAS DSM reset battery.charge.low to 10 or is it internal to the UPS? You will have to experiment by disconnecting the UPS control lead from the NAS and connecting it (if possible) to the Mac. After setting to 80 and a