similar to: apc with rs232

Displaying 20 results from an estimated 3000 matches similar to: "apc with rs232"

2019 May 29
1
apc with rs232
On Tue, 28 May 2019, nicolae788 wrote: > Apc uses a propietary serial cable and your convertar for sure it's wired > standard. Refer to the following link for info. > https://pinoutguide.com/UPS/apc_smart_cable_pinout.shtml > > Good luck > > On Tue, 28 May 2019, 15:13 , <grumpy at mailfence.com> wrote: > >> a friend gave me an old apc smart-ups 1250
2019 May 28
2
apc with rs232
On 5/28/19 3:39 PM, Julian H. Stacey wrote: > grumpy at mailfence.com wrote: >> a friend gave me an old apc smart-ups 1250 >> it has a rs232 interface but i have no pc with a rs232 port >> i attempted to use a rs232 to usb adapter but the ups goes nuts >> i connected the ups to batteries and verified it was working properly >> when i plug the usb cable into the pc
2019 May 28
0
apc with rs232
Apc uses a propietary serial cable and your convertar for sure it's wired standard. Refer to the following link for info. https://pinoutguide.com/UPS/apc_smart_cable_pinout.shtml Good luck On Tue, 28 May 2019, 15:13 , <grumpy at mailfence.com> wrote: > a friend gave me an old apc smart-ups 1250 > it has a rs232 interface but i have no pc with a rs232 port > i attempted to use
2019 May 28
0
apc with rs232
Hi, Reference: > From: Manuel Wolfshant <wolfy at nobugconsulting.ro> > Date: Tue, 28 May 2019 16:42:21 +0300 Manuel Wolfshant wrote: > On 5/28/19 3:39 PM, Julian H. Stacey wrote: > > grumpy at mailfence.com wrote: > >> a friend gave me an old apc smart-ups 1250 > >> it has a rs232 interface but i have no pc with a rs232 port > >> i attempted to
2019 May 28
0
apc with rs232
grumpy at mailfence.com wrote: > a friend gave me an old apc smart-ups 1250 > it has a rs232 interface but i have no pc with a rs232 port > i attempted to use a rs232 to usb adapter but the ups goes nuts > i connected the ups to batteries and verified it was working properly > when i plug the usb cable into the pc the ups shuts down > when i attempt to turn it on it beeps twice
2019 Sep 10
3
raspberry pi and tripplite_usb
i have a OMNIVS1500XL i have used nut for several years on a full sized pc with no problems i am trying to get nut working with this ups on a raspberry pi i tried with a pi 3b running raspbian stretch i tried with a pi 3b running raspbian buster i tried plugging the usb cable straight into the pi i tried using a powered usb hub i tried rebuilding nut from the source package all caused the pi to
2020 Jan 01
6
Belkin USB UPS Not Turning Off
On 1/1/20 9:56 PM, David White wrote: > > > On 1/1/2020 11:49 AM, David White wrote: >> >> Hi Roger and, as always, thanks! >> >> I really do not want to wait very long before shutting down things on >> this UPS. What I think I am doing (or at least trying to do) is to >> execute a script on the host machine when the UPS is detected by NUT to >>
2010 May 25
5
RS232 connection
I installed Board Master a software that control a CNC machine to produce PCB (Printed Circuit Board). The software install flawlessly but to check if it works I need RS232 working to control CNC machine. I tried to set connection parameters in Board Master choosing COM1 (the only available) but CNC machine don't move and software keep asking for switching machine on. Of course software and
2003 Nov 14
1
R and RS232-Interface?
Hi there Does any one of you know something about R and an implemented RS232-Interface? Are there any packages? Or is it possible to write an extensions or something like that in C/C++ ? The problem is that i should handle the information from a measuring device via the RS232-Interface (probably you know LabVIEW, which provides this functionality). These informations should then directly be
2019 Jun 26
1
[EXTERNAL] Re: Fixing Drops With SMART1500LCDXL & USB-HID Driver
this probably has no relevance to the subject but i have run a OMNIVS1500XL with the tripplite_usb driver for several years with no problem i am using a a powered usb hub if that make any difference
2008 Jun 05
2
centos RS232 to IP port program
Hi all, Is there a method in centos where a program can be started that listens on a given IP port and when something connects it will transfer data from the RS232 port to the IP port. reads and writes of course. Trying not to reinvent the wheel if I dont have to... Thanks, Jerry
2009 Sep 01
3
For you old-timers, an RS232 question about data rate confirmation.
Hello all. This is a question that I should be able to answer, but the old grey cells aren't working. My Google-Fu must not be up to snuff, either. I have a MOXA IP-RS232 converter that I'm going to be using over an RF WAN and I need to confirm the actual data rate that I'll be able to achieve. I have the drivers loaded (/dev/ttyr00) and a loopback plug on the end of the device. I
2010 Jun 07
6
Wine + winebottler + azloader.exe + rs232 to usb adapter
Hello guys. I am new in mac world and in wine apps. I have this singular situation: I have a macbook with wine and winebottler installed. I want to use this exe app: azloader.exe. Ok, wine is able to load it normally. But... the problem is, my macbook has not the RS-232 port. So I bought a RS-232 to USB adapter. I've installed the correct "drive" to use that. I've tried that in
2007 Nov 22
4
trouble with Cyber Power System CPS RS232 USB BRIDGE for UPS
Hi Recently i bought a MicroDoWell BP50, and with it followed a USB 2 serial converter. When i plug it into my 2.6.19 kernel, dmesg shows hiddev96: USB HID v1.10 Device [Cyber Power System CPS RS232 USB BRIDGE for UPS] on usb-0000:00:04.2-2 usbcore: registered new interface driver usbhid drivers/usb/input/hid-core.c: v2.6:USB HID core driver So, i figured i should use usbhid-ups,
2014 Jul 09
2
APC SmartUPS switches off with no reason
Hello One our customer has two Linux HP-branded servers powered from "clasic" APC Smart-UPS 2200 RM 2U (p/n SUA2200RMI2U). It is connected to first server via RS232c port with APC-branded cable. We have installed NUT 2.6.4 with apcsmart driver. This setup works fine for months. Two weeks ago all the hardware powered from the UPS started to switch off occasionally while on line
2018 Dec 27
4
APC Back UPS?
> >> Maybe it's not a standard ethernet-to-UPS cable? > > That's Ben's point - either it is actual Ethernet (usually found on an add-on UPS SNMP monitoring card, where the jack typically has two status LEDs, one on either side of the notch for the modular plug tab) that needs to go to another Ethernet jack on a NIC or a switch, or it is a proprietary APC cable that
2018 Dec 27
4
APC Back UPS?
On 12/26/18 8:55 AM, Charles Lepple wrote: > On Dec 25, 2018, at 4:07 AM, David Melik wrote: >> Lately I got (used) an APC Back UPS Pro 1000 and Back UPS NS 1080. I got an [8P8C]-to-USB cable from another UPS, but the Pro isn't detected (with usbhid-ups.) I haven't tried the NS yet but it seems to not be on the list though looks just like the Pro. >> > There are a few
2024 Jan 19
2
NUT and Eaton UPS produce a lot of error messages
On 19.01.24 17:02, Stefan Schumacher via Nut-upsuser wrote: >Jan 19 05:50:13 mars nut-monitor[849]: Signal 15: exiting >Jan 19 05:50:17 mars nut-server[1303]: Signal 15: exiting this looks like someone repeatedly killed nut server. This not a problem of UPS. -- Matus UHLAR - fantomas, uhlar at fantomas.sk ; http://www.fantomas.sk/ Warning: I wish NOT to receive e-mail advertising to this
2024 Jan 19
2
NUT and Eaton UPS produce a lot of error messages
I still have two questions: 1) How do I make the nut-server and nut-monitor find the right pid files? They are there but it seems they can't be opened. Permissions are nut/nut. 2) What do these error messages mean? Jan 19 16:14:52 mars nut-monitor[3781]: Init SSL without certificate database Jan 19 16:14:52 mars nut-monitor[3781]: Login on UPS [Eaton at localhost] failed - got [ERR
2024 Mar 20
1
UNSUBSCRIBE
Marcus, I did try to do that several days ago, got the email, confirmed my desire to unsubscribe, and wad told that my "request would soon be acted upon" Yet I continue to get these messages. I'd love to have just a way to receive only message chains where I either started the question or am contributing. I don't need to see ALL the comms on the list, however this old-school