2016 Jun 24
2
UPS is not turned off in slave-only configuration?
On Mittwoch, 22. Juni 2016 17:50, Roger Price wrote:
On Wed, 22 Jun 2016, Andr? H?nsel wrote:
> > Now, what I see is that when the UPS feeding server-1 goes LB,
> > server-1 is indeed shut down, but it seems that the UPS is never
switched off.
> >
> > This is a problem because when power is restored after shutdown, but
> > before the battery runs out (with no
2007 Jul 25
3
Nut fsd command ignored: bcmxcp_usb driver, Powerware 5105 UPS
Hi
I'm having a problem with the bcmxcp_usb driver FSD command: everything
seems to work apart from:
upsmon -c fsd
Environment: Ubuntu 7.04, nut 2.0.5-1, nut-usb 2.0.5-1, Powerware 3105
UPS.
upsd appears to send the FSD command to the UPS, upsmon then runs my
NOTIFYCMD (which halts my PC) but the UPS just doesn't turn off.
Here are the /var/log/daemon.log entries:
Jul 24 23:13:16
2020 Jan 11
4
System with MGE UPS shuts down too early
Hello,
I'm experiencing a strange early shutdown behavior with the following
system:
* */OS/*: Slackware Linux 14.2 x86_64
* */NUT/*: 2.7.4 (from my own package
<https://sotirov-bg.net/slackpack/pack.cgi?id=4083>)
* */UPS/*: MGE Ellipse PRO 1600
<powerquality.eaton.com/Products-services/Backup-Power-UPS/Ellipse-PRO.aspx>
(bought in September 2017)
*/Problem
2019 Dec 25
1
NUT not shutting down one of three UPSs (sometimes none of them shut down)
I have three APC SmartUPS 5000s. Two of them are AP9617 and one is AP9619.
I have a RS-232 connections from my monitor host to all three. All three
report status and give information.
One of the two AP9617 - ups3-1 - does not shut down when FSD is sent. It
did when I first set this system up a year or two ago but it's stopped
doing so since then. Resetting the management interface does not
2014 Jan 09
2
NUT clients - merits of authenticating
Hi,
I'd like to better understand the merits of NUT clients (slaves) properly authenticating with the NUT server (master).
NUT allows clients to retrieve UPS status (upsc ups at 10.10.10.1) without authenticating, shutdowns are properly trigger via polling.
From testing one apparent benefit of authenticating is the client receives the shutdown event more quickly rather than the polling
2020 Aug 08
3
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
upsmon.conf on server: https://pastebin.com/z4CrUTxb
nut.conf on server: https://pastebin.com/540ShZH7
Permissions for /etc/nut: https://hastebin.com/qecolodapi.diff
On the Synology (I didn’t edit any of these files):
ups.conf: https://hastebin.com/dedereqizi.shell
upsd.conf: https://hastebin.com/pupeseweda.css
upsd.users: https://hastebin.com/ocenamecex.cs
I don’t think I am able to run
2015 Feb 09
2
About your driver NUTDRV_ATCL_USB(8) for install
On Feb 9, 2015, at 6:48 AM, PERE (yahoo.es) <pererivers at yahoo.es> wrote:
> 0.028188 Can't set USB configuration: could not set config 1: Device or resource busy
> 0.029246 detached kernel driver from USB device...
> 0.030559 USB device [0001:0000] opened
> 0.866216 read: (8 bytes) => 03 00 00 00 00 00 00 00
> 0.866413 reply[0] = 0x03
2012 Jan 06
1
upsmon+snmp-ups does not shut down system
I've googled and RTFM'ed, but still can't solve this one. I hope you folks can.
This affects my entire computer cluster, but let's start simple: I've got a
computer running NUT; OS is Scientific Linux 5.5; kernel 2.6.18-274.12.1.el5xen.
It connects to an APC SMART-UPS via an APC SmartCard using the snmp-ups driver.
It generally works: upsmon will detect if the battery is low
2014 Jan 11
0
NUT clients - merits of authenticating
On Jan 9, 2014, at 4:00 PM, Lonnie Abelbeck wrote:
> Hi,
>
> I'd like to better understand the merits of NUT clients (slaves) properly authenticating with the NUT server (master).
>
> NUT allows clients to retrieve UPS status (upsc ups at 10.10.10.1) without authenticating, shutdowns are properly trigger via polling.
>
> From testing one apparent benefit of
2013 Sep 11
1
Issue with slave FSD notification on Windows port of NUT
I have the latest version of the Windows port of NUT installed on my Windows?7?machine. The UPS is connected via serial cable to the Windows machine. I also have my Synology NAS (which uses NUT) connected over the local network as a slave to the Windows NUT master. The Synology slave is configured to immediately go into "safe mode" whenever an FSD or OB+LB indication is received from the
2016 Nov 25
3
Can't get NUT slave to connect to master
Hi thanks Roger. Well I'm just using Ubuntu Server 16.04 LTS
I only ran that command as a few guides say that's how to establish if a
daemon is compiled with tcp wrappers:
https://www.cyberciti.biz/faq/tcp-wrappers-hosts-allow-deny-tutorial/
I haven't really used TCP wrappers before so I'm not even sure if my
hosts.allow entries are correct:
upsd : ipaddressofclientgoeshere
ups
2015 Feb 09
0
About your driver NUTDRV_ATCL_USB(8) for install
Dear Chales,
Thanks for your quick reply.
I have Raspberry with last Kernel [Linux pi1 3.18.6+ #753 PREEMPT Sun Feb 8
14:47:22 GMT 2015 armv6l GNU/Linux]
If <upsdrvctl>, <upsd> and <upsmon> are stopped <nutdrv_atcl_usb> Works well
without any error as "Device or resource busy".
If I run <upsc> command never receive any value from my ups <upsc
ups at
2016 Jun 22
0
UPS is not turned off in slave-only configuration?
On Wed, 22 Jun 2016, Andr? H?nsel wrote:
> Now, what I see is that when the UPS feeding server-1 goes LB, server-1 is
> indeed shut down, but it seems that the UPS is never switched off.
>
> This is a problem because when power is restored after shutdown, but before
> the battery runs out (with no load, it continues for quite a while),
> server-1 is not rebooted.
I'm
2016 Nov 25
2
Can't get NUT slave to connect to master
Try ALL:ALL in /etc/hosts.allow temporarily. If that still doesn't work, it's likely something else. If it does, only then screw with creating narrow rules . . .
- Tim
On November 25, 2016 6:37:02 AM CST, Roger Price <roger at rogerprice.org> wrote:
>On Fri, 25 Nov 2016, Jonah Naylor wrote:
>
>> upsd : ipaddressofclientgoeshere
>
>If it were me I would write
>
2012 Jan 04
3
NUT Windows port questions
An HTML attachment was scrubbed...
URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120104/34be491b/attachment.html>
2009 Jun 19
1
UPS does not want to power off itself
Greetings!
I have successfully installed and configured nut package. All i want now
is to power off ups. If i run upsmon -c fsd as root - everything goes
fine, system and ups gracefully shutting down. If i unplug power cable
from an ups, then system is down, but ups still on load. Any help would
be appreciated.
Debian Lenny x86
ups.conf
[ippon]
driver = megatec
port = /dev/ttyS0
2014 Apr 24
0
CyberPower CP1500PFCLCD and NUT upsset.cgi
Bill S wrote, On 4/15/2014 11:18 AM:
> The problem is that when I run upsset.cgi I first get a prompt for
> user name and password. I then enter the same username and password
> as I established in upsd.users and it seems to accept it.
upsset.cgi doesn't check that user/password is valid, it just tries it
when doing a command.
I just tested it, it is working for me on a remote and
2009 Mar 30
2
Why are files synced again and again when not using -a?
Hi,
usually I use rsync with -a but recently I used it without this option and
discovered that the same files are synced over and over again (as shown by
-v). Of course the rsync algorithm avoids the traffic but the files are all
listed.
As soon as I use -a for one time those files are not transferred again, even
when I remove the -a again.
So I suspect, when building the file list, rsync
2016 Nov 25
2
Can't get NUT slave to connect to master
Hi thanks Roger,
I've amended my hosts.allow file to your suggested one - thanks for that.
I'm still getting "Connection refused on the client cgi screen as well as
in the shell it gives me UPS upsname at ipaddresshere is unavailable...
Any ideas what I can try next to debug why it's not working. Also should
the "allowfrom = clientIPaddresshere" line be in my monuser
2016 Nov 25
2
Can't get NUT slave to connect to master
Hi thanks for helping.
I don't think nut is built with TCP wrappers support, although the package
is listed as depending on libwrap...
I ran this command: ldd /sbin/upsd | grep libwrap.so
and it has returned no output.
Does this mean I have to compile from source or is there a way to add the
tcp wrapper support?
Thanks again.
On 24 November 2016 at 22:40, Roger Price <roger at