similar to: NUT support for APC BackUPS Pro 900VA

Displaying 20 results from an estimated 5000 matches similar to: "NUT support for APC BackUPS Pro 900VA"

2016 Jan 21
1
NUT support for APC BackUPS Pro 900VA
Hi all, I'm trying to configure Nut to connect to an APC BackUPS Pro 900VA. This ups uses a serial port on which _simple_ or _smart_ signaling should be spoken. I've connected the UPS to a serial port using the original 940_0128A cable from APC. Unfortunately I've not yet managed to read any data from the ups. If I try to load the apcsmart driver it tells me that it cannot communicate
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi Arnaud, > Hi Thomas, > I just checked the 2.4.1 version of nut and found that you forgot to add > my old UPS model (APC Smart-UPS 900). I guess it is because you were > busy at the time when I sent you the patch. So here it goes again. :) > uh, right sorry. I was pretty sure I applied
2010 Jul 28
1
APC SmartUPS 2200XL + UDEV + USB = tcgetattr : Invalid argument
I need direction. I don't know what to google for anymore. I am unable to get my SmartUPS 2200XL to be recognized. My suspicions are that it's UDEV or Kernel related. I've updated the kernel to the highest version I feel comfortable with due to other things that run on the server, and I've updated UDEV a bit too. When I plug in the USB cable from the UPS into the server, I
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. >
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set
2009 Feb 27
0
support for APC Matrix 5000, vintage 12/00 (was: NUT apcsmart driver - firmware addition)
Hey Jarett, 2009/2/24 <jarett.stevens at usermail.com> > After upgrading to the 2.4.1 version, I wasn't able to read as many > variables from my UPS. After a bit of experimentation, I determined that > the firmware on my UPS was different than what is currently in the > apcsmart driver, though it had worked before. I located my firmware > version (5ZM), and added in
2008 Sep 19
1
APC SmartUPS 750 (SUA750) missing ambient data with usbhid-ups
I have a SmartUPS 750 (SUA750) which has the temperature and humidity SmartSlot card installed. When NUT 2.2 communicates with this UPS over /dev/ttyS0 using apcsmart, using the APC Smart cable connected to the SUA750 serial port, and this ups.conf: [su700] driver=apcsmart port = /dev/ttyS0 I can see the ambient temperature and humidity data with "upsc su700 at
2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all, Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h. Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS 1250 as a "dumb" UPS.) For NUT 2.0.5+. NUT 2.0.5: Patches apply successfully. Builds successfully. Works as expected under Ubuntu 7.04. NUT 2.2:
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
Listmates, After wrangling with the voltage value on the CyberPower 1000AVRLCD and now having 2 of them working, I though it would be a simple matter to move my APC BP650 from apcupsd to nut so that all 3 servers would be monitored on the same web interface. The APC is attached to an older box running openSuSE 11.0 with nut-2.2.2-66.1. (nut-classic). The APC BP650 uses a serial connection
2012 Feb 02
2
APC SmartUPS 3000VA LCD not connecting
We recently had to replace an old APC SmartUPS 3000 with a newer 3000VA (the 2U one). It has both serial and USB in the back (with an RJ-45 on the end of the serial cable). I can't get the apcsmart driver to connect. I figured it should work the exact same as the old UPS, with /dev/ttyS0 as the port (I'm using the same port on the server that the last one was plugged into). I even
2007 Jan 21
1
APC Smartups protocol - Hidden Programming Mode
Hej! Hope nut-upsuser is an appropriate place to post additional info about the smartups protocol, please tell me if not. I got an APC Smartups 2200 (5U Rack Mount, European/230V version, 48V batteries) a couple of days ago, was very happy to find the protocol description at http://www.networkupstools.org/protocols/apcsmart.html, and started to play. At the point when everything was working
2008 Jul 03
4
Old APC SmartUPS 1250, Nut 2.2.2 Fedora 9
Hi All, I've got two APC SmartUPS's that behave differently with nut, I have a SmartUPS1400 & a SmartUPS1250. I'm fairly sure this isn't a nut problem but more likely a problem with the age of the SmartUPS1250 and the apcsmart driver not being able to identify it. Under the APC Powerchute software the same monitoring & command parameters are available for both
2007 Dec 01
1
APC smartups 1500 is broken with usbhid-ups
I'm trying to setup a server controlling 8 ups, 6 APC Smartups 1500 and two 1000. Because of the number of ups, i connected them using usb cables. I'm using Debian Etch AMD64 and nut 2.2.0 from testing (already tried 2.0 from stable, but had problems reading the ups serials and all the following problems of 2.2). This is my ups.conf: [ups2] driver = usbhid-ups port =
2009 Feb 28
2
APC SMART-UPS 1500 always reporting LB
Using nut v2.2.2, and the APC serial cable. I have a client who's APC SMART-UPS 1500 (circa 2000) is always reporting LB. The batteries were old so they were replaced two weeks ago with brand new batteries. UPS still reported low batteries... I ran a calibration and a test on the unit (using the nut upscmd utility) During those tests, the battery charge on the unit goes to zero and slowly
2007 Dec 12
1
[PATCH]Support full capabilities on older Smart-UPS 600
Hi, The patch below adds support for a pair of old (circa 1993) APC Smart-UPS 600 devices that I have. They don't support the query mechanism of newer APC devices but do respond to the full Smart-UPS command set: battery.alarm.threshold: 0 battery.charge: 100.0 battery.charge.restart: 00 battery.date: 02/22/93 battery.runtime: 2040 battery.runtime.low: 120 battery.voltage: 27.67
2014 Jul 09
2
APC SmartUPS switches off with no reason
Hello One our customer has two Linux HP-branded servers powered from "clasic" APC Smart-UPS 2200 RM 2U (p/n SUA2200RMI2U). It is connected to first server via RS232c port with APC-branded cable. We have installed NUT 2.6.4 with apcsmart driver. This setup works fine for months. Two weeks ago all the hardware powered from the UPS started to switch off occasionally while on line
2015 Sep 30
0
Nut v2.7.3 - how to force shutdown for a specifc ups only
Hello Charles, >> On Sep 29, 2015, at 3:29 PM, Juergen Edner <juergen at eisfair.org> wrote: >> >> Now I wonder why it isn't possible to send a forced shutdown command >> to a specific UPS only. > > It is possible - simply send a "shutdown.reboot" or "shutdown.stayoff" > command via `upscmd`. > > Other instant commands (which
2013 May 07
2
Problems with USB-serial converters -- please advise on code fix
Hello! I've ran into this annoying issue when setting up a new server. I have an APC SmartUPS hooked up on a USB-serial converter on /dev/ttyUSB0. This works nicely, until: hub 3-0:1.0: port 1 disabled by hub (EMI?), re-enabling... pl2303 ttyUSB0: pl2303 converter now disconnected from ttyUSB0 usb 3-1: pl2303 converter now attached to ttyUSB1 apcsmart gets into an infinite loop of this:
2013 Jan 13
0
APC UPS: replacement battery always triggers shutdown
Arnaud, I was finally able to get back to this issue and would recommend adding these items to the FAQ #37 about recalibrating the UPS: 1a. It's important that the UPS be at 100% charge before starting the procedure; starting at lower will not work at all, not just produce inaccurate numbers. ? ? ? [I started the procedure when the UPS was at 91% charge. After that it would never report
2006 May 29
0
RE Basic Question
Hi Kaarl, > I work with APC SmartUPS which we use for the PrePass (Truck signaling and weigh station bypass system) system in > order to power our remote cabinets. We can access our SmartUPS 420s (mostly) from a UnixWare 2 computer that > has Ethernet communications to a serial comm server (Iolan) using a "cu" command: > cu i_ups. That gets me to the command line of