similar to: Anyone still have a Tripp-Lite 3004-protocol USB UPS?

Displaying 20 results from an estimated 10000 matches similar to: "Anyone still have a Tripp-Lite 3004-protocol USB UPS?"

2006 Feb 08
3
Tripp Lite is up to no good
Well, I have good news and bad news. I have a Tripp Lite SmartPro UPS attached to a Linux server running Ubuntu 5.10, and I'm running the just-released nut 2.0.3. I had error -71 from the UPS, which Charles Lepple correctly called out as a likely cable problem (thank you, Charles.) The cable provided with the UPS by Tripp Lite was just plain bad. Not too long, mind you- defective. I
2010 Jan 31
1
smart1050slt by tripp lite
I have 2 SmartUOS1050SLT's that apparently protocol 3004, has there been any progress on getting these units supported under nut? I am running version 2.4.1, and get the following output when starting the driver. #lsusb Bus 005 Device 002: ID 09ae:0001 Tripp Lite # upsdrvctl -DDDD start Network UPS Tools - UPS driver controller 2.4.1 Starting UPS: tripplite exec: /lib/nut/tripplite_usb -a
2010 Jan 31
3
smart1050slt by tripp lite
Original Message >I have 2 SmartUOS1050SLT's that apparently protocol 3004, has there >been >any progress on getting these units supported under nut? I am running >version 2.4.1, and get the following output when starting the driver. >#lsusb >Bus 005 Device 002: ID 09ae:0001 Tripp Lite ># upsdrvctl -DDDD start >Network UPS Tools - UPS driver controller 2.4.1
2014 Jun 26
1
The dreaded Tripp Lite SMART500RT1U and NUT
<nut-upsuser at lists.alioth.debian.org> I am doing my best to avoid have to spend $280 for a network monitoring card to put into a $190 UPS just to have some good remote monitoring capabilities. Rather, I would like to monitor my many 1U Tripp Lite's on my network using a Raspberry Pi running Raspian and using NUT. However, I cannot seem to get it working. And I while the hardware
2015 Mar 08
1
Problems communicating with Tripp Lite SMART500RT1U via USB with CentOS 6.6 and NUT 2.6.5
On March 6, 2015, at 6:17pm, Charles Leppe ,cleppe at gmail.com> wrote: If this is the same protocol 3005 that we saw in mid-2014 (USB ID: 09AE:0001), then support will be part of the upcoming NUT 2.7.3 release. You wouldn't happen to know anyone who would be able to publish the specs of that protocol, would you? ;-) That would help remove the "experimental driver" warning.
2007 May 11
1
Tripp Lite SMART2200RMXL2U and Fedora Core 6 (NUT 2.0.3)?
Hi, I'm running Fedora Core 6 and need to monitor a Tripp Lite SMART2200RMXL2U. I've loaded the nut-2.0.3-2.1 RPM. The UPS is connected via the provided USB cable, and that much appears to work: # dmesg | grep -i tripp hiddev96: USB HID v1.10 Device [Tripp Lite TRIPP LITE SMART2200RMXL2U ] on usb-0000:00:1f.4-2 # lspci | grep -i usb 00:1f.4 USB Controller: Intel Corporation 82801BA/BAM
2014 Nov 29
1
nut and Tripp Lite smart500rt1u on Scientific Linux 7
I installed nut from the epel repository on Scientific Linux 7. I would like to get my smart500rt1u working, but # upsc smart500 at localhost gives the following output: battery.voltage.nominal: 0 device.mfr: Tripp Lite device.model: SMART500RT1U device.type: ups driver.name: tripplite_usb driver.parameter.pollinterval: 5 driver.parameter.port: auto driver.version: 2.7.2 driver.version.internal:
2006 Jun 27
1
Tripp Lite OMNIVS1500XL Unknown protocol
Good afternoon, I'm trying without much success to monitor a Tripp Lite OMNIVS1500XL using NUT. I checked the compatibility list and saw that this UPS is supported by tripplite_usb. The system is running Debian Stable, but I've downloaded NUT 2.0.3 and compiled from source since the packaged 2.0.1 doesn't include tripplite_usb. I compiled --with-user=nut. My first attempt at
2014 Jul 01
2
The dreaded Tripp Lite SMART500RT1U and NUT
Hello Charles, Thank you for all of your help this far. I have made some great progress. I was hung up with all sorts of USB problems which we can chalk up to a "blonde moment" for me (or more accurately, a *bald* moment). In all my starting over and screwing around, I had forgotten to reinstall libusb-compat. Duh! I am now to a point that I think we can dig a little deeper. The
2012 Dec 07
2
Tripp Lite SMART1000RM2U
Hi, I recently purchased a Tripp Lite SMART1000RM2U UPS (http://www.tripplite.com/en/products/model.cfm?txtSeriesID=744&txtModelID=2657) and tried to configure the NUT with tripplite_usb driver and encounter the following problems: 1. battery.charge doesn't report correct charge level when the UPS is On Batter. It just reports 0. Even though it will report 100 when on line power. 2. I
2009 Nov 22
1
Tripp Lite SmartPro SMX500RT1U incompatibility
Greetings to all, I recently connected a Tripp Lite SMX500RT1U unit to a Synology NAS (basically a Marvell ARM equipped box running a custom 2.6.24 Linux). I tried using the tripplite_usb driver contained in nut 2.4.1 with not much luck. It does read the model ID and VA rating properly, but fails at everything else - mains voltage (this is a 230VAC EU model), battery config, unit status etc.
2012 Jun 06
1
no serial number for Tripp-Lite SMART3000RM2U?
I'm trying to set up a single host to monitor the state of several UPS in my data center. I have a mix of several APC and Tripp-Lite in production. The former are great, the latter are not so much. With the APCs (using usbhid-ups), I can set up configs for each based on the value they report from ups.serial. With the Tripp-Lites (using tripplite_usb), there is no value returned for
2006 Jan 13
1
help with TRIPP LITE SMART550USB
Hi I have a Tripp lite smartusb550 using fedora 3 (2.6.12-1.1381_FC3smp). Managed to establish communication with the ups using the tripplite_usb driver but get the following errors Any help to make it work will be appreciated cheers Julio -----------------------------------------------------------------------------------------------------------------------------------------------------
2014 May 16
2
Tripp Lite SMART3000RM2U (protocol 3003) running time and charge?
Hello, I own an older Tripp Lite SMART3000RM2U (protocol 3003). It does not work with usbhid-ups but it mostly works with the tripplite_usb driver (nut 2.7.1, the latest in the Gentoo tree), in the sense that the status (on line, on battery, etc.) is detected correctly, the machine is shut down on critical battery, and I can even get some information from the UPS. This is how it all looks:
2006 Sep 08
3
Tripp Lite OMNI900LCD
I have a Tripp Lite OMNI900LCD. It has a usb connector and claims to be USB/HID. I haven't been able to get it to work with newusbhid or tripplite_usb. Here's lsusb -v output: Bus 001 Device 013: ID 09ae:2005 Tripp Lite Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 (Defined at Interface level)
2015 Mar 07
0
Problems communicating with Tripp Lite SMART500RT1U via USB with CentOS 6.6 and NUT 2.6.5
On Mar 6, 2015, at 12:51 PM, Eric Cobb <Eric_Cobb at tripplite.com> wrote: > Network UPS Tools - Tripp Lite OMNIVS / SMARTPRO driver 0.20 (2.6.5) > Warning: This is an experimental driver. > Some features may not function correctly. > > Detected a UPS: Tripp Lite /TRIPP LITE SMART500RT1U > Unknown input voltage range: 0x02 > Unknown number of switchable load banks:
2012 Jun 15
1
Tripp Lite SMART2200CRMXL
I'm trying to get a SMART2200CRMXL to work with nut, using a USB cable. tripplite_usb -a upsname returns: Network UPS Tools - Tripp Lite OMNIVS and SMARTPRO driver 0.11.1 (2.2.2) Warning: This is an experimental driver. Some features may not function correctly. No matching USB/HID UPS found My system info: CentOS 5.5 nut installed from repo upsd version 2.2.2 TrippLite SMART2200CRMXL
2012 Feb 13
1
[HCL] Tripp-Lite Omnismart500 supported by tripplite_usb
Device manufacturer and name: Tripp-Lite OmniSmart500 upsc output: matt at backup:/etc$ sudo upsc tripplite battery.charge: 100 battery.test.status: Battery OK battery.voltage: 14.56 battery.voltage.nominal: 12 device.mfr: Tripp Lite device.model: OMNISMART500 device.type: ups driver.name: tripplite_usb driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.version: 2.4.3
2007 Mar 08
1
Tripp-Lite SU6000RT4U - not supported?
Greetings, I have a Tripp-Lite SU6000RT4U unit connected via USB and RS-232. # tripplitesu -DD -u root -a tl6000 Unable to detect Tripp Lite SmartOnline UPS on port /dev/ttyS0 # tripplite -DD -u root -a tl6000 Failed to find UPS - giving up... # newhidups -DD -u root -a tl6000 Checking device (09AE/4002) (001/003) - VendorID: 09ae - ProductID: 4002 - Manufacturer: Tripp Lite - Product: TRIPP
2014 Jun 29
1
The dreaded Tripp Lite SMART500RT1U and NUT
Hello Charles, I think we are making progress! I grabbed nut using git, and applied your patch without any problems. Getting to the point that I could run a configure on my RPi - was something else. I found this blog post, which was very helpful (for anyone else that may try it): http://atelier-orchard.blogspot.com/2013/11/raspberry-pixf86-video-fbdev.html It's not in English, but you get