Displaying 20 results from an estimated 2000 matches similar to: "APC Powerchute Network Shutdown, or APC Symmetra"
2019 May 07
1
Symmetra LX 16000
I have a Symmetra LX 16000 UPS with a Network Management Card (Schneider
Electric, I think).?? Can NUT be configured to report from this unit and
shutdown hosts based upon messages from this unit?
2024 Mar 04
0
Newer APC Back-UPS spurious events
Hi,
[ There is also a github issue about this here:
https://github.com/networkupstools/nut/issues/2347 ]
I have an APC Back-UPS BX1600MI purchased in January, attached by
its supplied USB cable to a Debian 10 machine. Initially using the
nut packaged in Debian 10 (2.7.4-8) this was unusable as the
usbhid-ups driver kept disconnecting every few seconds.
I upgraded to the git HEAD of nut and
2008 Feb 06
4
PCNS for CentOS and APC ups's
Apparently there is only an Itanium client for RHEL according to APC? I need to setup a few boxes to shut down safely and don't know if the PCNS 2.2.3 Linux version will do it? Anyone know why it needs Java as well? (Blegh)
Assuming APC is fairly popular, how do you guys shutdown your CentOS boxes with a UPS with a management card in it?
Thanks!
jlc
-------------- next part --------------
An
2013 Jan 13
0
APC UPS: replacement battery always triggers shutdown
Arnaud,
I was finally able to get back to this issue and would recommend adding these items to the FAQ #37 about recalibrating the UPS:
1a. It's important that the UPS be at 100% charge before starting the procedure; starting at lower will not work at all, not just produce inaccurate numbers.
? ? ? [I started the procedure when the UPS was at 91% charge. After that it would never report
2006 Jun 01
0
"Battery constant" value for APC UPS
Hi all,
Thought I'd forward this on, as the apcsmart driver doesn't appear to
have any support for this (admittedly obscure) setting and it doesn't
seem to be listed at http://www.networkupstools.org/protocols/apcsmart.html.
Hope someone finds it useful.
Later,
Russ
--
Russell Odom
http://www.gloomytrousers.co.uk/
Fast, cheap, good: pick two.
-------- Original Message --------
2007 May 07
3
newhidups/APC: load always 0?
'lo,
UPS model: APC Back-UPS BR 800 (supplied by Dell)
My USB connection:
Bus 001 Device 002: ID 051d:0002 American Power Conversion Back-UPS Pro
500/1000/1500
# upsc desk@localhost|grep load
ups.load: 0.0
This UPS has 2 pc's and some minor other gear connected, yet the load
stays at 0.0 when checking with nut.
driver.version: 2.0.5
driver.version.data: APC/CyberPower HID 0.9
2008 Feb 19
1
Success report: APC Back-UPS RS 800
Hi all,
First of all, I would like to thank everyone who was involved in the
development of NUT. Although it took me some time to set it up, now it
appears to be working very well. Thanks for the good software!
This is my success report for an APC Back-UPS RS 800:
khali at mahadeva:~> upsc rs800
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.date: 2001/09/25
2018 Mar 03
2
APC UPS wrong input voltage
Folks,
I've asked this question on the FreeNAS forum but there are no ideas there
as it looks like it's a NUT issue.
Original question:
https://forums.freenas.org/index.php?threads/apc-ups-reporting-wrong-input-voltage.60888/
the nut driver is reporting the wrong input voltage. I am in the UK, 230V
but it's reporting circa 108.
If I connect it to the laptop and run powerchute it
2008 Sep 19
1
APC SmartUPS 750 (SUA750) missing ambient data with usbhid-ups
I have a SmartUPS 750 (SUA750) which has the temperature and humidity
SmartSlot card installed. When NUT 2.2 communicates with this UPS over
/dev/ttyS0 using apcsmart, using the APC Smart cable connected to the
SUA750 serial port, and this ups.conf:
[su700]
driver=apcsmart
port = /dev/ttyS0
I can see the ambient temperature and humidity data with "upsc su700 at
2018 Nov 29
0
Problem to connect to APC SC1500
Hello,
I am not able to get NUT working with a APC SC1500.
The ups has only a serial port and came with a 940-0272a serial to usb cable. The cable has a fake Prolific chip in it, so only works by downgrading the driver to version 3.2. I tested a 940-0024C cable without success as well.
The ups works with powerchute and apcupsd with the 940-0272a cable. Have not tested it with the other one.
OS:
2008 Jul 03
4
Old APC SmartUPS 1250, Nut 2.2.2 Fedora 9
Hi All,
I've got two APC SmartUPS's that behave differently with nut, I have a
SmartUPS1400 & a SmartUPS1250.
I'm fairly sure this isn't a nut problem but more likely a problem with
the age of the SmartUPS1250 and the apcsmart driver not being able to
identify it. Under the APC Powerchute software the same monitoring &
command parameters are available for both
2012 Dec 04
2
Does NUT include support for older UPSD servers?
I have a network with two older systems protected by APC UPSs. Both
systems run OS/2 and will continue to do so. Both systems have APC
PowerChute Plus 4.2.3 installed and I can use that software to monitor
and control both systems.
I am also now running several linux systems, in fact I spend almost all
my time on the linux systems and these OS/2 systems are servers running
in the
2006 Nov 27
2
using nut to monitor SNMP UPS unit
Hi all,
I've been trying to build NUT (latest release source) on a pretty "standard"
CentOS (RHEL style) linux box, to monitor an APC Symmetra UPS Unit which
powers our server room and broadcasts information via SNMP to appropriate
clients.
I am having some trouble even encouraging NUT to build with snmp support,
which doesn't seem to happen by default.
I am curious if anyone
2006 Feb 20
1
preventing automatic reboot
Hello,
I'd like to prevent my servers from rebooting when power comes back after a
power failure. With powerchute (which I used before), there is an "automatic
reboot" parameter. Is there an equivalent with nut ?
Regards
--
Frantz de Germain
Web : http://www.info.univ-angers.fr/pub/frantz
Membre de la Soci?t? d'Astronomie de Nantes : http://www.san-fr.com/
2015 Jul 01
1
Need help
Hi,
I run os x yosemite and found out about NUT tonight. I messed around with fink and macports but get stuck very soon.
I dont know how to install anything that doesnt have a .dmg or .pkg installer.
Does anyone have a step by step (written in "for dummies" format on how to get this all to work? Just looking for a PowerChute alternative that actually lets me control and monitor my
2007 Oct 25
3
Upcoming USENIX/LISA conference
Greetings -
Does anyone have plans for a Puppet BOF at LISA this year? I''ve seen
some talk on the LOPSA configmgmt list about Config Mangement BOF''s,
but nothing focused on Puppet. Please, Please, mom, can we have a BOF,
PUHLEESE!!!!
Luke - I hope you''ll be there so I can at least buy you dinner and
beers/drinks for making my SA life easier with Puppet.
Cheers,
Jeff
2005 Aug 17
0
Re: Problems compiling snmp-ups on Solaris
Hello Kim,
First, I've forwarded your mail to the nut user mailing list.
Thanks to register there (https://alioth.debian.org/mail/?group_id=30602)
and we'll follow on the thread on it.
> Terribly sorry to bother you, but I was hoping to get nut to work with
> our Symmetra, which uses SNMP. nut-2.0.2 built fine on my Solaris 8 box,
> but when I do "make build-snmp" it
2018 Mar 27
0
problem with nut APC BackUPS RS 1500 (white)
Hello, i have this strange problem with APC BackUPS RS 1500 ? older one model, white one
under windows in powerchute is device OK, working everything ok selftest ok, just ordinary ups.
under CentOS 7 minimal (CentOS-7-x86_64-Minimal-1708.iso)
kernel version 3.10.0-693.el7.x68_64
driver version 2.7.2
i have this strange probem: nut driver didnt start automatically with error,
after i enter in
2018 Mar 27
0
problem with nut APC BackUPS RS 1500 (white)
Hello, i have this strange problem with APC BackUPS RS 1500 ? older one model, white one
under windows in powerchute is device OK, working everything ok selftest ok, just ordinary ups.
under CentOS 7 minimal (CentOS-7-x86_64-Minimal-1708.iso)
kernel version 3.10.0-693.el7.x68_64
driver version 2.7.2
i have this strange probem: nut driver didnt start automatically with error,
after i enter in
2012 Oct 12
1
Puppet liveManagement very slow
Hi ,
I have installed puppet enterprise , master and agent in two nodes in a
cluster.
Everything works perfeclty except live mangement console . clicking this
option take lot of time and finally it doesnot come up. It came 1 or 2
times.
Can you explain what could be reason?
Thanks
Leo
--
You received this message because you are subscribed to the Google Groups "Puppet Users"