similar to: Documenting the NUT driver-qualification process

Displaying 20 results from an estimated 7000 matches similar to: "Documenting the NUT driver-qualification process"

2014 Jul 26
0
Documenting the NUT driver-qualification process
Hi Eric, sorry for the lag, summer time... I'm first seconding Charles comments 2014-07-09 12:31 GMT+02:00 Eric S. Raymond <esr at thyrsus.com>: > I think the time for me to get involved in NUT documentation has come > again. > welcome back > Late last week I had to buy a UPS under time pressure. The Eaton unit > that thus project gifted me with in 2006(?) died
2014 Jul 29
1
APC protocols and drivers (was: Documenting the NUT driver-qualification process)
Hi Ted there was a drift from the initial topic. worth a new thread! 2014-07-27 9:13 GMT+02:00 Ted Mittelstaedt <tedm at mittelstaedt.us>: > On 7/26/2014 12:18 PM, Arnaud Quette wrote: > >> Hi Eric, >> >> sorry for the lag, summer time... >> >> I'm first seconding Charles comments >> >> 2014-07-09 12:31 GMT+02:00 Eric S. Raymond <esr
2014 Jul 09
0
Documenting the NUT driver-qualification process
On Jul 9, 2014, at 6:31 AM, Eric S. Raymond <esr at thyrsus.com> wrote: > What I'd like to do is this: confer in real-time, perhaps via IRC, > with someone who knows this process. Ask about every step (thought > processes and diagnostics). *Write them down* and turn this into a > document on how to qualify and support a new device. Happy to help, but scheduling something
2014 Jul 09
2
Documenting the NUT driver-qualification process
On 7/9/2014 6:51 AM, Charles Lepple wrote: > On Jul 9, 2014, at 6:31 AM, Eric S. Raymond<esr at thyrsus.com> wrote: > >> What I'd like to do is this: confer in real-time, perhaps via IRC, >> with someone who knows this process. Ask about every step >> (thought processes and diagnostics). *Write them down* and turn >> this into a document on how to qualify
2014 Jul 09
0
Documenting the NUT driver-qualification process
On Jul 9, 2014, at 11:24 AM, Ted Mittelstaedt <tedm at mittelstaedt.us> wrote: > Someone could write a driver for MODBUS for NUT, all of the information > and materials are available to do it. The simple fact of it is that the > reason no one has done so is that the apcupsd program is available. You're right, it's the microlink protocol that they have been promising to
2014 Jul 10
1
Documenting the NUT driver-qualification process
On 7/9/2014 4:16 PM, Charles Lepple wrote: > On Jul 9, 2014, at 11:24 AM, Ted Mittelstaedt<tedm at mittelstaedt.us> > wrote: > >> Someone could write a driver for MODBUS for NUT, all of the >> information and materials are available to do it. The simple fact >> of it is that the reason no one has done so is that the apcupsd >> program is available. > >
2014 Dec 17
2
interrupt pipe disabled [APC SMT3000RMI2U]
On Dec 16, 2014, at 9:45 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote: > Bye the way I just realize that I can't retrieve the ups.load, among other > thing :-( To the best of my knowledge, Microlink is not supported by any third-party tools (including NUT), but some variables are exposed via standard USB HID. Apparently, ups.load is not one of them. Your UPS might
2014 Dec 17
0
interrupt pipe disabled [APC SMT3000RMI2U]
Le Tue, 16 Dec 2014 20:38:50 -0500 Charles Lepple <clepple at gmail.com> ?crivait: > On Dec 16, 2014, at 9:45 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote: > > > Bye the way I just realize that I can't retrieve the ups.load, among other > > thing :-( > > To the best of my knowledge, Microlink is not supported by any third-party tools
2013 Sep 11
2
New APC "SMT" UPSes support MODBUS, will there be support in NUT?
Hi All, About a month ago APC announced they were including MODBUS protocol support in their new APC UPSes. The technical note on this is here: http://www.apcmedia.com/salestools/MPAO-98KJ7F/MPAO-98KJ7F_R0_EN.pdf "Application Note #176 Modbus Implementation in APC Smart-UPS" The APC "announcement" appeared on their site in their user blogs by an APC employee, here:
2013 Sep 13
0
New APC "SMT" UPSes support MODBUS, will there be support in NUT?
Hello Ted, 2013/9/11 Ted Mittelstaedt <tedm at mittelstaedt.us> > Hi All, > > About a month ago APC announced they were including MODBUS protocol > support in their new APC UPSes. The technical note on this is here: > > http://www.apcmedia.com/**salestools/MPAO-98KJ7F/MPAO-**98KJ7F_R0_EN.pdf<http://www.apcmedia.com/salestools/MPAO-98KJ7F/MPAO-98KJ7F_R0_EN.pdf>
2014 Dec 16
4
interrupt pipe disabled
Hello, I'm testing an APC SMT3000RMI2U connected to an USB port with Nut 2.7.2. I've got the message : "interrupt pipe disabled (add 'pollonly' flag to 'ups.conf' to get rid of this message)" I've been looking for "pollonly" in the usbhid-ups man page, but it didn't help me. Could someone explain me what does this means exactly ? What are
2014 Dec 17
2
interrupt pipe disabled [APC SMT3000RMI2U]
On Dec 17, 2014, at 3:46 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote: > This seems to me a little bit complicated :-( Instead, can I use the > apcsmart driver with the provided 940-0625a c?ble (RJ45/DB9 connectors) ? Or > do I need to acquire an AP9620 SmartSlot expansion card, as I've seen in the > Hardware compatibility list page ? It sounds like you might
2014 Mar 27
3
New UPS supported in 2.0.4
Hi, I need to get a USB based UPS for a system which is running NUT 2.0.4 (a Debian Etch system). Does anyone know of a UPS that I can buy today that is supported by 2.0.4? Unfortunately upgrading the OS (and NUT) isn't an option. Previously, we used the Powerware 5110 (which used the bcmxcp_usb driver) and that worked fine, however that UPS has been discontinued and is no longer
2007 May 29
9
Asking hard questions about the NUT architecture
I've spent the better part of two working days reading the NUT code and documentation and thinking about typical modern use cases for the software. I'm now questioning whether I want to get any further involved with this project, because it seems to me that the codebase is a huge and complicated pile of machinery mainly aimed at solving problems that no longer matter. I could be wrong
2015 Apr 28
2
答复: I love NUT
Carsten, This is a common issue in technology when you have complex products that the majority of consumers of those products do not understand how they operate. If most UPS customers understood the importance of standardization they would have refused to purchase non-standard UPSes and all UPSes would have long ago standardized on a single management protocol. The normal thing is that product
2014 Dec 18
0
interrupt pipe disabled [APC SMT3000RMI2U]
> Also, I don't think we have any confirmation of the variables that the AP9620 provides. Here is the list of full 'upsc' output for various APC models: > > http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/APC/index.html Frantz, Actually, it would be useful if you could send a copy of the output of 'upsc', 'upscmd -l' and
2014 Dec 16
0
interrupt pipe disabled
Le Tue, 16 Dec 2014 15:36:29 +0100 Frantz de Germain <frantz at info.univ-angers.fr> ?crivait: > Hello, > > I'm testing an APC SMT3000RMI2U connected to an USB port with Nut 2.7.2. I've > got the message : > > "interrupt pipe disabled (add 'pollonly' flag to 'ups.conf' to get rid of this message)" > > I've been looking for
2013 Jul 07
3
How to find out the output of "upsc" for each UPS model supported by NUT ?
Hi When purchasing a new UPS, one of the major functionalities I would assess, is the support is has by NUT. We have the http://www.networkupstools.org/stable-hcl.html page, where we can see if a UPS is supported, and what the level is. But I would really like to have more knowledge. I would like to know how the output from the "upsc" looks, so I know what values I will get from the
2013 Feb 26
1
APC SMX3000RMLV2UNC with AP9631 NUT compatibility via network
I have an APC SMX3000RMLV2UNC UPS, with installed network card model AP9631. http://www.apc.com/resource/include/techspec_index.cfm?base_sku=SMX3000RMLV2UNC http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9631 I planned to use network connectivity with this unit and apcupsd, but have not this far. The UPS is shared by multiple servers, so a USB or Serial connection via the
2014 May 27
1
Masterguard UPS A3000
Hi, I'm trying to talk to an old Masterguard UPS A3000 so I can determine current load and status etc, to determine the best replacement options. After a fair amount of google fu, and attempting different things, this is where I have ended up. First, environment: OS: Linux (Debian Stable) NUT Version: 2.7.2-1 (Debian unstable package) UPS details (on the rear lable): Manufacturer: