powercom upstype identify problem
Mr Claesson,
with my current configuration, the ups.status when the UPS is disconnected from the mains is "OB". There is no more "OB BOOST". Now my upsd.users is:
[root]
password = password
allowfrom = localhost
upsmon master
actions = SET
instcmds = ALL
and upsmon.conf is:
RUN_AS_USER root
MONITOR Inform@localhost 1 root password master
MINSUPPLIES 1
SHUTDOWNCMD
2006 Aug 18
0
(no subject)
Dear Mr Claesson,
prepare for quite a long letter from me. I hope you will have time to read it. I bestowed a whole morning on trying to identify the correct upstype. Here are the results:
root@marto:/home/marto# /usr/local/ups/bin/powercom -DD -u root -a Inform -x type=KP625AP
Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.4)
debug level is '2'
2006 Aug 17
2
powercom UPS shoutdown discussion
Thank you for your response.
The point is that I have configured my system to shut down at the event "upsc Inform@localhost ups.status"!="OL", not at "LB". So there will be no /etc/killpower file created. At an ups.status != "OL" event, the following script named "notifyme" is run:
echo `date` >> /root/upsLog
echo " No power, shutting
2006 Aug 16
5
Master privileges unavailable on UPS, no access :(
Hello!
After I type "upsmon", in syslog the following message appears:
Aug 16 14:11:09 marto upsmon[7731]: Master privileges unavailable on UPS [Inform@localhost]
Aug 16 14:11:09 marto upsmon[7731]: Reason: Access denied
Can you tell me where my error is, my configuration files are:
ups.conf:
[Inform]
driver = powercom
port = /dev/ttyS0
desc = "inform guard"
linevoltage = 220
2006 Dec 11
2
howto setup BNT-1500AP on gentoo
Good afternoon. I try to put nut on gentoo. Has executed installation
by a standard command emerge nut. All has passed successfully. I use
UPS POWERCOM BNT-1500AP. It is connected to serial port 1, i.e. for my
system it/dev/tts/0. In/etc/nut/ups.conf
[powercom]
driver = powercom
port = /dev/tts/0
desc = "PowerCom BNT-1500AP on IP-PBX"
modelname = "BNT-1500AP"
linevoltage = 230
2005 Jul 06
0
Powercom BNT-1500AP
Hey all,
Does anybody know there is a full working setup for the PowerCom
BNT-1500AP. I got some stuff working with the Powercom driver and the
type set to "KIN1500AP". But it seems that there is still missing
usablity. I was wondering if anybody found any better configs?
---- excerpt of ups.conf
[AVR1500]
driver = powercom
port = /dev/ttyS0
desc =
2007 Oct 04
0
Powercom black knight 800AP (serial)
Hi,
Nut versions: 2.2.0 and 2.0.2 (powercom -x type=KIN1500AP -x linevoltage=220)
I've got the above mentioned serial UPS and have found some problems using
it.
1) under linux 2.6.12 select() timed out on reading the serial port
in NONBLOCK mode.
Not sure about this one, seems most likely a kernel problem, since it's
working OK in 2.6.20. But on the other hand it was a nasty one.
For
2007 Nov 06
1
BNT-1000AP
Hi guys,
We've got a BNT-1000AP (powercom) BlackKnight UPS that works with the
KIN1500AP model in the powercom driver. Well, almost. It seems the
input frequency and the battery charge is swapped around:
# upsc blackknight at localhost
battery.charge: 46.5
driver.name: powercom
driver.parameter.manufacturer: BlackKnight
driver.parameter.modelname: BNT-1000AP
driver.parameter.port:
2005 Jul 30
0
Sustainer S-1000C
Hi,
I have a UPS of the Israeli company Sustainer, model S-1000C
(http://www.sustainer.co.il/data/files/specifications%20smart%20en.pdf -
don't worry, it's in english...).
I've been trying to connect to it from Debian to no avail for a long time
now.
The company has attached to it a program called Commander Pro (for windows)
and RPMs of UPSmart for old versions of Redhat and
2005 Aug 19
1
Sustainer S-1000C (Powercom protocol)
Hi,
I've sent the following message 3 weeks ago, yet have recieved no reply at
all. I don't want to nag, but could anyone please help me?
Thanks,
Dror
------------------
Hi,
I have a UPS of the Israeli company Sustainer, model S-1000C
(http://www.sustainer.co.il/data/files/specifications%20smart%20en.pdf -
don't worry, it's in english...).
I've been trying to connect to
2007 Dec 29
1
Odd Values For Powercoms
All,
I'm using the Powercom driver from 2.2 (not the one recently mailed to
thelist).
Since it's a KIN2200AP, I'm using the driver settings right from the
manpage.
All the values look "sane" when I'm on-line, but note some of the odd
values (<-- Here) when on battery:
Also, does anyone know if this UPS supports logging of the "boost" or
2006 Apr 21
1
Powercom BNT-1200AP
Hello
I have UPS Powercom Black Knight Pro 1200 (BNT-1200AP)
I try to use nut, but powercom driver not understand my model
Ok, i try to use type KIN1500AP and it's work
But powercom driver can't set UPS's shutdown delay time
Also i have powercom's original program (upsmon), and this program can do it
What can i do for help to add this function to nut's powercom driver?
For
2009 Nov 20
1
ULTRA 2000 ULT33046 configuration
Howdy,
I've been trying for a while now to get this running. Can anybody
please tell me what the proper configuration is for this unit ???
This is what I've got/tried so far:
# cat ups.conf
# Start with
#
# # upsdrvctl -u nut -D start MEGATEC
MODE=netserver
user=nut
# Ultra ULT33046 2000 VA 1200 W
2005 Dec 30
2
BNT600AP
Hi,
I have a little problem with PowerCom BNT600AP after running driver I
see: root@rask> powercom -D /dev/ttyS1
Network UPS Tools - PowerCom and similars protocol UPS driver $
Revision: 0.5 $ (2.0.2)
debug level is '1'
Values of arguments:
manufacturer : 'PowerCom'
model name : 'Unknown'
serial number : 'Unknown'
line
2006 Jul 08
0
Powercom BNT-600AP and NUT (powercom driver)
Hello,
I'm new there. I bought an UPS Powercom BNT-600AP. It's compatible
in NUT with driver powercom and protocol type KIN1500AP.
But I have a simple problem: the 'upsc' shows wrong values in
battery.charge (maybe in other rows also /ups.load, voltages?/) - if
battery is 100% charged it shows only 92.6% or 93.0%.
I thing I have wrong values in driver parameters: batteryPercentage,
2006 Aug 17
1
powercom issues
And something else, that previously eluded from my thoughts:my "notifyme" script,i.e the script that is executed at an ups.status="OB" event, is:
echo `date` >> /root/upsLog
echo " No power, shutting down the system!" >> /root/upsLog
sleep 30
control=`/usr/local/ups/bin/upsc Inform@localhost ups.status`
if [ $control != OL ]
then
2012 Jul 21
0
Re Powercom Vanguard driver for nut
Hi
Have been trying to get nut and Powercom Vanguard 2000 ups communicating
?
in the /lib/udev/rules.d/52-nut-usbups.rules file we have this entry
#? PowerCOM VGD - Vanguard? - usbhid-ups
ATTR{idVendor}=="0d9f", ATTR{idProduct}=="0004", MODE="664", GROUP="nut"
?
In the /etc/ups/ups.conf
[UPS]
??????? driver = usbhid-ups
??????? port =
2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
Hello all.
Try this driver (for nut 2.2.0). See attach.
- Trust, KP625AP, Egys models stay as it was
- add Powercom's Black Knight Pro model support ( BNT-400/500/600/800/801/1000/1200/1500/2000AP
220-240V )
- add Powercom's King Pro model support (
KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V)
- add Powercom's Imperial model support ( IMP-xxxAP,
2009 Dec 27
4
XPCC XVRT-1000 driver
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Has anyone used nut with a XPCC UPS, in particular one of the XVRT
units? Their supplied monitoring tool "works", but I'd really prefer to
use nut if possible. I've systematically gone through each of the
drivers in /lib/nut and none seem to talk with the unit properly.
I'll be talking with a XPCC support person tomorrow, though
2011 Jul 08
2
Ubuntu 10.04 Ultra 700VA UPS Setup Nut
I just bought an Ultra UPS system for my linux server, and I need help
getting it set up. It's an Ultra 700VA UPS.
NUT INFORMATION: Package (apt-get install nut)
NUT VERSION: Latest
Driver: I don't have one?
Here's the device information from my syslog:
Code:
Jul 7 23:25:27 eric-desktop kernel: [ 3045.609066] usb 2-1: USB
disconnect, address 3
Jul 7 23:25:30 eric-desktop