similar to: Multiple UPS monitoring, relaying

Displaying 20 results from an estimated 7000 matches similar to: "Multiple UPS monitoring, relaying"

2007 Apr 12
1
APC 1500 USB problem
Hello, We have two APC Back-UPS RS 1500 USB stuff, and i've got a bit of a problem with it and NUT. The usbdevs output: addr 2: Back-UPS RS 1500 FW:8.g8 .I USB FW:g8, American Power Conversion addr 3: Back-UPS RS 1500 FW:8.g8 .I USB FW:g8, American Power Conversion (UPS1 and UPS2) I've configured our NUT system to monitor the UPSes, and it went very fine till the time had arrived for a
2009 Nov 15
3
two MGE Ellipse 1500 ups via usb
Hi, I've got two MGE Ellipse 1500 UPS connected via usb to an ubuntu jaunty system with nut and libupsclient1 2.4.1-2ubuntu4. As soon as I start the driver for the second one, they start fighting each other and I get no data. I found an older post to this list that said: If you want to monitor multiple UPSes through usbhid-ups, you *must* make sure that each one can be uniquely identified
2012 Mar 04
2
NUT Two Apc UPSes on Windows
Hi, I've got a question about managing two UPSes under NUT. I have two similar model APC usb-connected UPSes to work with, but don't know how to manage them simultaneously from under Windows. Long story short, my ups.conf looks like this: --- ups.conf --- [ups1] driver= usbhid-ups port= auto serial=AS1054340323 [ups2] driver= usbhid-ups port= auto serial=AS1026662626 ---
2005 Dec 24
1
Regular expressions in upssched.conf?
Hi, I didn't found an answer for my question in NUT documentation/FAQ or this mailing list archive so I?m posting it here. I want to start a timer only if both of my UPSes remain on battery. Not just one, both. My UPSes are: - ups1@host-a - ups2@host-b Is it possible to use something like this in upssched.conf? AT ONBATT ups1.* && ups2.* START-TIMER onbattwarn 180 Thanks,
2017 Nov 30
2
SNMPv3 fails when more than one UPS is configured in ups.conf
New NUT install dealing with three APC Smart-UPS 5000s, two of which have AP9617 and the third has a AP9619 card. The SNMPv3 configurations on all three are exactly the same. This is confirmed by snmpget calls that work just fine: snmpget -Cf -v3 -u [...] -l authPriv -A '[...]' -X '[...]' -a MD5 -x DES [upsname] .1.3.6.1.4.1.318.1.1.1.1.1.1.0 snmp-ups can query all three
2007 Apr 20
1
USB problem as user
Hello I'm having a bit of a trouble to set up a Back-UPS on a production box. We're using the newhidups driver for this module here, in the office, and I'd like to monitor the one, out in our server farm. The situation is the following: # /lib/nut/newhidups -u root -DD -a ups1 2> ups1.out Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30 (2.0.5) this one worked
2008 Feb 07
1
usbhid-ups and "data stale"
Hello I'm using nut 2.2.0 on FreeBSD 7.0-RC1. I've got two UPSes (Back-UPS RS 1500) connected to the host, and I often see them to go away. All the system logs are full of "Poll UPS [ups1 at upshost] failed - Data stale". What causes this issue? Is this a known issue, is it going to be fixed? What farther investigations should I do to get some more info on this issue? --
2017 Dec 04
2
SNMPv3 fails when more than one UPS is configured in ups.conf
Hi Charles, Running upsdrvctl -D start on the host with all three configured to SNMPv3 kicks out 56 different "unhandled ASN 0x81 from ..." lines on all three but importantly they all start up and keep running. I'm starting to suspect the startup is taking so long that systemd is timing out and killing it. time -p reports real time of 133.27. I'm not a fan of systemd but
2007 Nov 09
2
UPSSched UPSNAME env variable
Hi everybody, i'm trying to use the UPSNAME environment variable within the script launched by upssched, and although it is correctly written and thus read by my script, it doesn't get updated when multiple UPSes are configured. To be more precise i'm monitoring 2 UPSes and using AT *EVENT* * *OPERATION* *handle *to manage events in upssched.conf. Am i wrong somewhere? I'm
2011 Jul 27
3
nut with 2 salicru ups
Hi, my name is Sebasti?n from Spain I need help for that. I have 2 salicru ups I need monitor with a fedora 14 pc. Someone knows if i can configure ups.conf to monitor one or another ups? only make a upsc "ups" for take data. The upses are connected via usb and nut always read the first one connected. The upses are the same model. Thanks for all! Sebasti?n Le?n del Moral urticaries at
2019 Mar 26
0
Bug: upssched and 3+ UPSes
Hi, I've stumbled over a race condition in upssched when using 3 or more UPSes in combination with START-TIMER/CANCEL-TIMER. I have a solution that works but is ugly, so I'm going to describe the bug here in the hope somebody can come up with a better solution. The problem is in upssched.c:629 check_parent() (see https://github.com/networkupstools/nut/blob/master/clients/upssched.c ).
2012 Jul 18
1
bcmxcp_usb: multiple UPS
I can't find a way to configure bcmxcp_usb to communicate with 2 UPS units. Maybe more simply, I can't find a way to tell the driver to only talk to one of the units on the bus. That is, I cannot find that the driver configuration file supports "serial =" or "bus = " or other such discriminators that other drivers do (usb_apc, etc.). So, I can't assign one Eaton
2023 May 17
2
Synthesize low batt (LB) fron SNMP UPS which does not support this?
Makes sense, and a PR is a way to solicit feedback :) I'd document this for ups.conf (man page and examples), including a note that for devices which do provide a healthy LB these values may be set to 0 safely. Wondering if non-zero defaults should be there anyway. @Community, WDYT? Also, this critical-state check should be done only when the UPS is on battery (and perhaps not calibrating),
2014 Jan 21
2
Shutdown when both (all) UPS on battery / low battery
On Jan 21, 2014, at 8:05 AM, Rafa? Oleszek wrote: > MONITOR UPS_251 at localhost 2 monmaster password master > MONITOR UPS_252 at localhost 2 monmaster password master I think the "2"s here should be "1". "powervalue is an integer representing the number of power supplies that the UPS feeds *on this system*." So if UPS_251 is connected to one power supply on
2019 Dec 25
1
NUT not shutting down one of three UPSs (sometimes none of them shut down)
I have three APC SmartUPS 5000s. Two of them are AP9617 and one is AP9619. I have a RS-232 connections from my monitor host to all three. All three report status and give information. One of the two AP9617 - ups3-1 - does not shut down when FSD is sent. It did when I first set this system up a year or two ago but it's stopped doing so since then. Resetting the management interface does not
2014 Jan 21
3
Shutdown when both (all) UPS on battery / low battery
On Jan 21, 2014, at 3:16 AM, Rafa? Oleszek wrote: > I would like to mention that MINSUPPLIES manipulation doesn't work. My nut version is : 2.2.2-4 (RHEL 5) What do your configuration files look like? Setting MINSUPPLIES to 2 should work. You can run upsmon with a debug level of 3 or greater, and it will print the current and minimum "power value", which is what determines
2015 Sep 11
3
"upsmon -c fsd" cause system shutdown
hi: my testing server has two power supply and attach to two ups. one of the ups is connect to the server with usb. my upsmon.conf like below: # for two ups MONITOR ftups at localhost 1 monmaster nutmaster master MONITOR ftups at 10.1.1.2 1 monslave nutslave slave MINSUPPLIES 1 # for early shutdown NOTIFYFLAG ONBATT EXEC+WALL+SYSLOG NOTIFYFLAG ONLINE EXEC+WALL+SYSLOG NOTIFYCMD
2014 Jan 21
0
Shutdown when both (all) UPS on battery / low battery
> What do your configuration files look like? Setting MINSUPPLIES to 2 should work. You can run upsmon with a debug level of 3 or greater, and it will print the current and minimum "power value", which is what determines when to shut down. > > Also, if you don't want to wait for both UPSes to drain to the low battery state, you can set up a pair of dummy-ups drivers. I'm
2008 Jul 22
1
MGE Pulsar EX1500 RT comms problem
Hi, I have the above UPS connected to a FreeBSD 6.2 box and it shows 'data stale' very frequently (every few minutes). I have tried the usual trick of setting maxage, poll interval, etc etc but to no avail. When I wind up logging I see (on mge-shut) entering shut_get_report(id: 0d, len: 1800) shut_wait_ack(): ACK received entering shut_get_report(id: 16, len: 1800) shut_wait_ack():
2009 May 05
5
upsd flapping in the breeze
Hi, I have had a long standing problem with NUT talking to 110V MGE UPSs on FreeBSD, I was recently investigating again and noticed that upsd seems overly noisy, eg.. May 5 03:50:36 egbert upsd[96662]: UPS [ups1] data is no longer stale May 5 03:50:36 egbert upsd[96662]: Data for UPS [ups1] is stale - check driver May 5 03:50:36 egbert upsd[96662]: UPS [ups1] data is no longer stale May 5