2007 Apr 20
2
Multiple UPS monitoring, relaying
Hello,
I've got a setup with NUT, where we've got two UPSes,
ups1 and ups2. UPS1 supports our servers, while UPS2
supports our desktop boxes. We monitor both of them
via USB on a box now called "upsmon".
The interesting point comes here. We monitor both
UPSes on the upsmon box, but if UPS2 fails, which
supports our desktop boxes, NUT shouldn't initiate
a shutdown in
2007 Apr 20
1
USB problem as user
Hello
I'm having a bit of a trouble to set up a Back-UPS on
a production box.
We're using the newhidups driver for this module here, in
the office, and I'd like to monitor the one, out in our
server farm.
The situation is the following:
# /lib/nut/newhidups -u root -DD -a ups1 2> ups1.out
Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30
(2.0.5)
this one worked
2009 Nov 15
3
two MGE Ellipse 1500 ups via usb
Hi,
I've got two MGE Ellipse 1500 UPS connected via usb to an ubuntu
jaunty system with nut and libupsclient1 2.4.1-2ubuntu4.
As soon as I start the driver for the second one, they start fighting
each other and I get no data. I found an older post to this list that
said: If you want to monitor multiple UPSes through usbhid-ups, you
*must* make sure that each one can be uniquely identified
2017 Nov 30
2
SNMPv3 fails when more than one UPS is configured in ups.conf
New NUT install dealing with three APC Smart-UPS 5000s, two of which
have AP9617 and the third has a AP9619 card.
The SNMPv3 configurations on all three are exactly the same. This is
confirmed by snmpget calls that work just fine:
snmpget -Cf -v3 -u [...] -l authPriv -A '[...]' -X '[...]' -a
MD5 -x DES [upsname] .1.3.6.1.4.1.318.1.1.1.1.1.1.0
snmp-ups can query all three
2012 Mar 04
2
NUT Two Apc UPSes on Windows
Hi,
I've got a question about managing two UPSes under NUT.
I have two similar model APC usb-connected UPSes to work with, but don't
know how to manage them simultaneously from under Windows. Long story
short, my ups.conf looks like this:
--- ups.conf ---
[ups1]
driver= usbhid-ups
port= auto
serial=AS1054340323
[ups2]
driver= usbhid-ups
port= auto
serial=AS1026662626
---
2005 Dec 24
1
Regular expressions in upssched.conf?
Hi,
I didn't found an answer for my question in NUT documentation/FAQ or
this mailing list archive so I?m posting it here.
I want to start a timer only if both of my UPSes remain on battery. Not
just one, both.
My UPSes are:
- ups1@host-a
- ups2@host-b
Is it possible to use something like this in upssched.conf?
AT ONBATT ups1.* && ups2.* START-TIMER onbattwarn 180
Thanks,
2017 Dec 04
2
SNMPv3 fails when more than one UPS is configured in ups.conf
Hi Charles,
Running upsdrvctl -D start on the host with all three configured to
SNMPv3 kicks out 56 different "unhandled ASN 0x81 from ..." lines on all
three but importantly they all start up and keep running.
I'm starting to suspect the startup is taking so long that systemd is
timing out and killing it. time -p reports real time of 133.27. I'm not
a fan of systemd but
2012 Jul 18
1
bcmxcp_usb: multiple UPS
I can't find a way to configure bcmxcp_usb to communicate with 2 UPS units. Maybe more simply, I can't find a way to tell the driver to only talk to one of the units on the bus. That is, I cannot find that the driver configuration file supports "serial =" or "bus = " or other such discriminators that other drivers do (usb_apc, etc.). So, I can't assign one Eaton
2019 Dec 25
1
NUT not shutting down one of three UPSs (sometimes none of them shut down)
I have three APC SmartUPS 5000s. Two of them are AP9617 and one is AP9619.
I have a RS-232 connections from my monitor host to all three. All three
report status and give information.
One of the two AP9617 - ups3-1 - does not shut down when FSD is sent. It
did when I first set this system up a year or two ago but it's stopped
doing so since then. Resetting the management interface does not
2005 Dec 04
1
Back-UPS RS6000
Hi all,
I have an APCC Back-UPS XS 1000 (it's a USB device) that I'm using with
nut 2.0.2 that came with Fedora Core 4. It reports itself like this:
Back-UPS RS 1000 FW:7.g8 .D USB FW:g8
in the nut web status page, which seems a tad messy. It otherwise works
fine, except I don't get any information on the input and output
voltages. I'm using the hidups driver.
My
2011 Mar 14
1
UPS Support
I am currently trying to use your NUT program to monitor a SMART3000RMOD2U TRIPP LITE device. I find that it connects with the in the device folder as hiddev0 and if I connect a second device it connects under hiddev1. I attempted to use your software with the driver=usbhid-ups and port=auto, but when I try to discover it it can't be found. Then when I run the command /sbin/usbhid-ups -a
2007 Dec 01
1
APC smartups 1500 is broken with usbhid-ups
I'm trying to setup a server controlling 8 ups, 6 APC Smartups 1500
and two 1000. Because of the number of ups, i connected them using usb
cables.
I'm using Debian Etch AMD64 and nut 2.2.0 from testing (already tried
2.0 from stable, but had problems reading the ups serials and all the
following problems of 2.2).
This is my ups.conf:
[ups2]
driver = usbhid-ups
port =
2009 May 05
5
upsd flapping in the breeze
Hi,
I have had a long standing problem with NUT talking to 110V MGE UPSs on
FreeBSD, I was recently investigating again and noticed that upsd seems
overly noisy, eg..
May 5 03:50:36 egbert upsd[96662]: UPS [ups1] data is no longer stale
May 5 03:50:36 egbert upsd[96662]: Data for UPS [ups1] is stale - check driver
May 5 03:50:36 egbert upsd[96662]: UPS [ups1] data is no longer stale
May 5
2011 Jul 26
0
[RFC] PowerChain: add LIST POWERCHAIN and GET POWERCHAIN to the client (network) protocol
Hi,
this is the 2nd part of the PowerChain RFC.
2011/6/13 Arnaud Quette <aquette.dev at gmail.com>
> As already presented, the links below will describe in details the
> PowerChain notion:
>
> https://wiki.ubuntu.com/ServerOneiricInfraPower
> https://wiki.ubuntu.com/ServerOneiricInfraPower#PowerChain%20design
>
2013 Oct 09
2
Updated to 2.6.5, previously-working APC SmartUPS now fails completely
(Note that I mentioned this *was* previously working with an older version
of Nut).
[irs2-ups1]
driver = snmp-ups
port = irs2-ups1.sum.naoj.org
mibs = auto
community = private
irs2-ups1.sum.naoj.org responds to pings.
On Tue, Oct 8, 2013 at 3:55 PM, Tim Rice <tim at multitalents.net> wrote:
> On Tue, 8 Oct 2013, Philip Tait wrote:
>
> > Here is the upsc
2012 Jan 25
1
A patch to add a command to get client information
Hello!!
I'm a sysadmin at La Laguna University in Spain. We are using NUT to manage
our UPS with great success, but we miss a feature and we would like to send
this patch to you.
If you apply this patch running upsd -c info you'll get information about
client connections in syslog. This is very simple and helpfull if you have
hundreds of servers connected to the same upsd.
Thank you for
2019 Mar 26
0
Bug: upssched and 3+ UPSes
Hi,
I've stumbled over a race condition in upssched when using 3 or more UPSes in combination with START-TIMER/CANCEL-TIMER.
I have a solution that works but is ugly, so I'm going to describe the bug here in the hope somebody can come up with a better solution.
The problem is in upssched.c:629 check_parent() (see https://github.com/networkupstools/nut/blob/master/clients/upssched.c ).
2011 Jul 27
3
nut with 2 salicru ups
Hi, my name is Sebasti?n from Spain
I need help for that. I have 2 salicru ups I need monitor with a fedora 14 pc. Someone knows if i can configure ups.conf to monitor one or another ups? only make a upsc "ups" for take data. The upses are connected via usb and nut always read the first one connected. The upses are the same model.
Thanks for all!
Sebasti?n Le?n del Moral
urticaries at
2007 Feb 07
1
Network Management Card (MGE) 66102 with snmp-ups
I'm trying to set up nut with a MGE UPS equiupped with a network
management card, but encountered a problem.
UPS: MGE Pulsar M 3000
Network Management card (installed in the UPS): 66102 (2006 edition)
Operating system: FreeBSD
Nut port version: 2.0.5
Nut driver: snmp-ups
According to MGE in Norway this card is supported by nut, but only
the old version of the card (66244) is listed on
2008 Jul 22
1
MGE Pulsar EX1500 RT comms problem
Hi,
I have the above UPS connected to a FreeBSD 6.2 box and it shows 'data
stale' very frequently (every few minutes).
I have tried the usual trick of setting maxage, poll interval, etc etc
but to no avail.
When I wind up logging I see (on mge-shut)
entering shut_get_report(id: 0d, len: 1800)
shut_wait_ack(): ACK received
entering shut_get_report(id: 16, len: 1800)
shut_wait_ack():