Displaying 20 results from an estimated 700 matches similar to: "Where to buy a db9 serial port probe"
2018 Jul 04
1
FE700VA over USB? controlling UPSes over network?
Lately I replaced my 10+-year-old server with a nano-ITX-type one
that has USB but not old serial ports. I connected my FE700VA to
DB25-to-9-to-USB cables, but haven't been able to set it up. Apparently
my DB9-to-USB cable (Prolific Technology, Inc. PL2303 Serial Port) has
issues needing old software (setserial?) and some new software
(fconfigure) being changed. Has anyone managed
2006 Dec 05
0
SOLVED: DB9 e1 to RJ45 pinout
Hi guys,
just to let u known the pinout for the adapter :
Adapter for connect the E1 telco lines on my digium card
DB9 RJ45
3 1
8 2
2 4
6 5
Adapter used for connect the Hicom150 traditional PBX on my digium card (cross connection)
DB9 RJ45
3 4
8 5
2 1
2010 Jul 01
1
HP R3000 XR (BCMXCP) serial connection problem: e7!!! and e2!!!
UPS: HP R3000 XR with HP UPS Management Module
What I Want:
I just want the UPS to shut down the client called "tor" before the UPS
power drains out, I'd prefer to use a direct serial cable instead of
network, in case the network doesn't work.
I'll manage the UPS trough the ethernet using the built-in HTTP
webinterface in the HP UPS Management Module.
I've created a
2004 Sep 10
1
Sangoma S508 Rev-B
Hi list,
I've browsed through the wiki pages and finally would like to get some
answers from peple who perhaps had used such card. I have the sangoma
s508 card. It has no CSU/DSU. It is an ISA card with DB9 and DB25
connectors (for RS232 and V34/X21/EIA interfaces). They claim it is a
frame relay and syncronous ppp card.
Can I use this card with asterisk in any way but without
2005 Oct 23
1
Nut setup with CyberPower AVR900
Hello,
I'm a new to NUT and I'm having some setup problems.
Here's my setup:
Nut 2.0.2
Gentoo Linux 2.6.13-r3
CyberPower AVR900
According to the hardware compatibility guide this setup should work.
Here's what I get:
root@gentoo (0) [552] % upsdrvctl start
Network UPS Tools - UPS driver controller 2.0.2
Network UPS Tools - CyberPower driver 1.00 (2.0.2)
2008 Jun 18
1
APC Smart-UPS RT 5000
Hello all
I've a brand-new APC box, model Smart-UPS RT 5000, which comes with a black
cable RJ48 in one side (10P4C) and RS232-DB9 in the other. The cable
reads "940-1525A" in the DB9 side.
Which is the best setting (driver and options) to connect this UPS to my
computer? It seems not to be recognized by a typical apcsmart driver setting.
Many thanks
Noel Torres
er Envite
2020 Mar 25
2
[EXTERNAL] thoughts on tripp lite Smart Online UPSs?
Re: "Does it work well with NUT?"
Assuming it is the SU5000RT4UHV, the similar units I've tried seemed to work fine. For reference, the SU5000RT4UHV should be a 4004 USB protocol.
________________________________
From: David Zomaya
Sent: Wednesday, March 25, 2020 5:21 PM
To: Lee Damon; nut-upsuser Mailing List
Subject: Re: [EXTERNAL] [Nut-upsuser] thoughts on tripp lite Smart
2011 May 03
1
Asterisk, bicolor BLF and DEVSTATE
Hi,
1. You can now find several SIP harphones with bicolor BLFs (see Polycom,
Cisco, ...).
Is there a protocol which best describes how to use this bicolor BLD feature
?
2. I would like to map these BLFs to the following user activities :
- user is logged off: no light
- user is logged in: green light
- phone is ringing: blinking light
- user is on call: red light
It seems that
2014 Dec 17
0
interrupt pipe disabled [APC SMT3000RMI2U]
Le Tue, 16 Dec 2014 20:38:50 -0500
Charles Lepple <clepple at gmail.com> ?crivait:
> On Dec 16, 2014, at 9:45 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
>
> > Bye the way I just realize that I can't retrieve the ups.load, among other
> > thing :-(
>
> To the best of my knowledge, Microlink is not supported by any third-party tools
2014 May 03
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 3, 2014, at 5:20 AM, Charles Lepple wrote:
> On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote:
>
>> Hi,
>>
>> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5.
>>
>> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu,
>> with nut-2.2.1. Ubuntu system uses ASUS motherboard.
>>
>> On mini-ITX system, I
2012 Feb 15
2
[newbie] separating plot output from debug output
I'm attempting to refactor an R script that does a lot of plotting,
among other things. Ideally I'd like to do something like
setup # does pdf(...)
for each part of input {
plot(process(part))
}
cleanup # does dev.off()
but have problems:
1 I'm plotting to PDF, so everytime I dev.off() creates a new file,
and I want everything in one file (as does my boss :-)
2 I'm
2004 Jul 26
3
TE405P and E1
Hello
Im from Denmark and i've just got my Digium TE405P. But i have some
problems when i connect it to my E1 connection (ISDN30).
My telco delivered a alcatel box witch have a G.703 120ohm (DB9 with a
serial to rj45) and a 75ohm coax connection.
I've tried to connect using the 120ohm with rj45 and a ordinary utp cable.
But it dosent seem to work. I've tried several zaptel.conf
2006 Jan 24
1
Ellipse driver problem
Hi,
i had purchase a MGE-Ellipse 500 and i'm trying to use the DB9 F / RJ45
cable send by MGE with UPS. Which driver i'm suppose to use:
mge-utalk or mge-shut ?
When i try mge-utalk i've got this message:
# upsdrvctl start
Network UPS Tools - UPS driver controller 2.0.0
Network UPS Tools - MGE UPS SYSTEMS/U-Talk driver 0.80.3 (2.0.0)
Startup timer elapsed, continuing...
and there is
2006 Mar 23
1
TrippLite SmartPro UPS and nut-2.0.2
I have a TrippLite SmartPro UP (SMART3000RM2U) that shipped with the DB9
cable# 73-0866. nut doesn't recognize the UPS using the tripplite
driver. I found this page:
http://www.tripplite.com/support/download/PA12/help/device.htm
The link lists the SmartPro series as using the cables 73-0724 or 73-0844 and
the Internet 350/525 is listed as using a cable 73-0866. I have a few
73-0844s
2020 Mar 25
5
thoughts on tripp lite Smart Online UPSs?
We're looking at replacing some old APC SmartUPS 5000s with something
that has USB so NUT can more easily talk with it (and yes, I've tried
USB-RS232 adapters and every one I tried started kicking out errors
within a few hours).
One of the bids we have is for a "Tripp Lite UPS Smart Online 5000VA
4500W Rackmount 5kVA 200V/240V" as the potential replacement unit. I
have no
2015 Apr 27
1
Contact closure UPS?
Hello again! I'm yet again the guy from the blazer_usb problem and the
ATCL one too. This time I have a third UPS (the last one In my collection)
that i'm trying to make work instead of the ATCL one since there's no
driver for it on windows.
This UPS is another no-brand box (actually it is a "kozumi", but that's
just a rebrand), and apparently it's much more basic
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the
manufacturer's PowerChute software and smart signaling, so I have
decided to try NUT. The smartups driver can't make contact through
the serial port.
Since this is rack-mounted, it comes with a 940-1524 serial cable.
As far as I can tell, this is supposed to work with smart signaling.
Here's my ups.conf:
2004 Dec 16
3
Has anyone connected to 7960 with console cable for setup?
I have a Cisco 7960 phone. I cannot seem to use the settings button to get
into the phone to change the TFTP server. I've set up a DHCP Server, TFTP
Server with the same address, and the phone requests the address of 0.0.0.0,
the server offers the address of 192.168.2.2, but the phone seems not to
take it.
I have no action on the TFTP side.
So, since I can't seem to server the phone
2008 Dec 04
1
Battery Volts shown as 20+ on Cyber Power UPS CP1000AVRLCD [ DATA ]
Citeren "David C. Rankin" <drankinatty at suddenlinkmail.com>:
> Discharged battery.voltage:
>
> 17.4 Volts - (indicated on shutdown, discharging battery.charge 77%)
> 16.9 Volts - (indicated on shutdown, discharging battery.charge 51%%)
> 16.6 Volts - (indicated on shutdown, discharging battery.charge 33%)
>
> -- Shutdown Occurred at < 3% -- Battery
2013 May 24
1
Utility to scan for unpassworded SSH privkeys?
I like to retain some semblance of optimism for humanity, and so I'm just going to hope that this assertion is false. I have to hope that there is at least a large minority of people who correctly use ssh-agent for the suppression of password prompting, and protect their private keys with passwords.?
-------- Original message --------
From: Dan Kaminsky <dan at doxpara.com>
Date: