2013 Jun 07
1
cannot update battery.date value of APC ups battery
Hi, I'm running this command: # upsrw -s "battery.date=2013Jun7" -u ups-mon-IT "IT-APC-BOTTOMRIGHT at 127.0.0.1" Password: OK but I'm getting this listing: # upsc IT-APC-BOTTOMRIGHT at 127.0.0.1 battery.alarm.threshold: 0 battery.charge: 100.0 battery.charge.restart: 15 battery.date: 01/10/06 battery.packs: 000 battery.runtime: 1440 battery.runtime.low: 120
2015 Nov 26
2
output.voltage on a CyberPower CP1350PFCLCD
nut 2.7.2 linux 3.18.7 CyberPower CP1350PFCLCD The LCD shows the same for input and output, my multimeter also matches the input voltage. But nut is giving me different numbers. How do I debug this? input.voltage: 122.0 output.voltage: 138.0 I still need to check what it does on battery and what the other readings are. But the voltage stuck out at me.
2008 Dec 04
1
Battery Volts shown as 20+ on Cyber Power UPS CP1000AVRLCD [ DATA ]
Citeren "David C. Rankin" <drankinatty at suddenlinkmail.com>: > Discharged battery.voltage: > > 17.4 Volts - (indicated on shutdown, discharging battery.charge 77%) > 16.9 Volts - (indicated on shutdown, discharging battery.charge 51%%) > 16.6 Volts - (indicated on shutdown, discharging battery.charge 33%) > > -- Shutdown Occurred at < 3% -- Battery
2018 Dec 03
2
MGE EllipseMAX 1500 shuts down after a few hours
I have taken out the batteries and measured them with a multimeter. They put out 13V (they are rated 12V 9Ah). Putting them back again and disconnecting the UPS from the mains it is kept on, powering all the connected devices. The shutdowns only occur when the UPS is being monitored. Are you sure it's a battery problem? Do UPS perform further tests when they are being polled for data?
2015 Dec 03
0
output.voltage on a CyberPower CP1350PFCLCD
[please use reply-all to include the list. thanks!] > On Nov 26, 2015, at 9:47 AM, Weedy <weedy2887 at gmail.com> wrote: > > nut 2.7.2 > linux 3.18.7 > CyberPower CP1350PFCLCD > > The LCD shows the same for input and output, my multimeter also > matches the input voltage. > But nut is giving me different numbers. How do I debug this? > > input.voltage:
2005 Jan 10
2
Ring Voltage Supplied by Wildcard TDM400P REV E/F & AUTO FXS/DPO
Hi; I'm trying to connect a TDM400P with an FXS module to a Valcom V-9940 Paging adaptor. This port on the TDM400P was connected to a 2500 Set and was working I just re-connected it to the Valcom (which is known to work on a Telco POTS line) and its not picking up. The Valcom docs say it need a minimum of 75 Volts at 20-30 Hz to recognize a call... So the question is what ring voltage
2013 Feb 28
8
false low battery alarm
Hi, I have two types of UPS devices and one of them (APC) gave me a false "low battery" alert. I can't reproduce the problem... Also, there was nothing apparently wrong with the UPS at the time of the false alert. All I could do was grab the driver values within a minute after the "low battery" notification. These are the values: battery.runtime.low : 120
2020 Jan 27
3
System with MGE UPS shuts down too early
On 1/25/20 10:53 AM, Georgi D. Sotirov wrote: > OK, so yesterday evening I done a real test cutting of the power to > the UPS. And it went good... the UPS supported my server for 28:50 > minutes (i.e. the expected runtime with this load), before forcing > shutdown. The batteries could still hold as charge was 30 % with about > 15 minutes run time. And the UPS did hold for
2007 Jul 16
1
Problem to sort factor
Hello, I'm having a problem renaming and sorting the underlying factor of a ggplot2 based plot. Here's my code: ---8<---------- > delta <- ggplot(subset(data, Model==c("dyn", "dl4", "dl3")), aes(x=Problemsize, y=Fitness)) + geom_smooth(size=1, color="black", fill=alpha("blue", 0.2))+ geom_point(size=0.5,
2015 Jun 30
2
Help With Physical Layer
------ Original Message ------ From: "Tony Kasule" <timotsmith at gmail.com> To: "Asterisk Users Mailing List - Non-Commercial Discussion" <asterisk-users at lists.digium.com> Sent: 30/06/2015 8:34:47 p.m. Subject: Re: [asterisk-users] Help With Physical Layer >Hello, > >Anyone to help me with this issue? It has never worked :( Hi Tony I'm not
2007 Jun 16
1
Lines connecting the boxes in a boxplot
Hello, I'm currently using a boxplot to visualize data for three different models. As I have three models, I'm plotting three parallel boxplots for each factor. This works fine - what I need now is a line connecting the medians of each boxplot of each model. I want to do this in order to visualize the trend that one of the models exhibit. Basically, I want to plot a curve for each model
2020 Apr 28
2
Tripp-Lite SMART1500LCD: powers off with /etc/killpower...then powers back on...
Hi Everyone, I recently bought a Tripp-Lite SMART1500LCD for my Linux Mint 19.3 machine, connected via a USB cable. I installed Nut 2.7.4 from the Mint package repository via sudo apt update && sudo apt install nut. Everything works great: NUT issues low battery warning when it reaches the set low battery point and then issues shutdown commands...computer shuts down..then the UPS shuts
2018 Dec 03
0
MGE EllipseMAX 1500 shuts down after a few hours
On Dec 2, 2018, at 7:55 PM, raul <raulvior.bcn at gmail.com> wrote: > > I have taken out the batteries and measured them with a multimeter. They put out 13V (they are rated 12V 9Ah). What sort of load did you have in parallel with the multimeter? (This is why Wolfy mentioned the light bulb: if the battery has developed excessive internal resistance, it will show proper voltages when
2020 Jan 27
1
Nut-upsuser Digest, Vol 175, Issue 30
Roger, here is my output of ps -elf |grep upssched root at nutpi:~# ps -elf |grep upssched 0 S root 1242 1191 0 80 0 - 1834 pipe_w 05:23 pts/0 00:00:00 grep upssched No timer, just the grep of upssched.. On Mon, Jan 27, 2020 at 4:27 AM <nut-upsuser-request at alioth-lists.debian.net> wrote: > Send Nut-upsuser mailing list submissions to >
2007 Jun 04
1
Where to buy a db9 serial port probe
All I apologize if this is slightly off topic, but I'm in the process of trying to get NUT working and I've discovered the need for a serial port probe that is native db9 - native db9 (the thought of hanging a probe plus two db9-db25 adapters plus a cable on a UPS bothers me greatly). I'm not looking for anything fancy, just a little gender changer with a buncha LEDs on it.
2014 Jan 10
2
How to treat UPS status of TRIM as on line
I am using NUT 2.6.5 as part of FreeNAS 9.2.0. I am using an APC Smart-UPS 5000 RM DL4 with a AP9619 network management card. NUT properly detects when the UPS goes on battery and initiates a shutdown after the configured time. The problem I have is that I am using a 208V unit on a 240V circuit. That means the normal state for the UPS is "TRIM". NUT doesn't treat that as an on line
2014 Jan 11
0
How to treat UPS status of TRIM as on line
On Jan 10, 2014, at 12:58 PM, Elliot Dierksen wrote: > I am using NUT 2.6.5 as part of FreeNAS 9.2.0. I am using an APC Smart-UPS > 5000 RM DL4 with a AP9619 network management card. NUT properly detects > when the UPS goes on battery and initiates a shutdown after the configured > time. The problem I have is that I am using a 208V unit on a 240V circuit. > That means the normal
2017 May 10
4
How to detect fake CallerID? (8xx?)
On Wed, 10 May 2017, J Montoya or A J Stiles wrote: > Presumably your staff carry mobile phones. What about an app that gets > the ID of the cell tower to which it is connected, and passes it and the > SIM number in a HTTP request to a server you control? The problem is that they are supposed to use the 'site landline' to confirm presence -- not their cell phone with the
2017 May 11
2
How to detect fake CallerID? (8xx?)
Seems like this is the best idea (challenge-response), a callback. No matter the callerid, you don't know where the caller is. But if you place a call BACK to the callerid, it's going to go to the destination. Then you either need the phone to be answered, or the phone to be answered and and the challenge entered. Adam Goldberg AGP, LLC +1-202-507-9900 -----Original Message-----
2014 Jan 11
1
How to treat UPS status of TRIM as on line
> On Jan 10, 2014, at 12:58 PM, Elliot Dierksen wrote: >> I am using NUT 2.6.5 as part of FreeNAS 9.2.0. I am using an APC >> Smart-UPS >> 5000 RM DL4 with a AP9619 network management card. NUT properly detects >> when the UPS goes on battery and initiates a shutdown after the >> configured >> time. The problem I have is that I am using a 208V unit on a 240V