Displaying 20 results from an estimated 4000 matches similar to: "Tipp-lite SU1500XL"
2014 Jul 03
2
The dreaded Tripp Lite SMART500RT1U and NUT
> Lots of good progress here! I tried to enable a few more commands for
> your model. For instance, the "M" values seem to be min/max voltage,
> so there is a "reset.input.minmax" command to use with upscmd. Also,
> you can trigger a battery test with "test.battery.start". I assume the
> work the same way as on Protocol 3003 :-)
Hello Charles,
The
2020 Jan 01
2
[EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Hello List, David: I’ thanking you … :-)
I’m using the tripplite_usb driver and the barcode on mine says: 9347AIOBC470902728 or 9347A10BC470902728.
with pictures…
https://drive.google.com/file/d/1SJWDr0g95KOD-FpbOPHUyl9bsbOKePlD/view?usp=sharing
https://drive.google.com/file/d/1SFMT-GbZRcRO03gEy_7SszZ43-LYmEZM/view?usp=sharing
2012 Feb 13
1
[HCL] Tripp-Lite Omnismart500 supported by tripplite_usb
Device manufacturer and name:
Tripp-Lite OmniSmart500
upsc output:
matt at backup:/etc$ sudo upsc tripplite
battery.charge: 100
battery.test.status: Battery OK
battery.voltage: 14.56
battery.voltage.nominal: 12
device.mfr: Tripp Lite
device.model: OMNISMART500
device.type: ups
driver.name: tripplite_usb
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version: 2.4.3
2014 Jun 17
3
Question about recycle power of Tripp Lite UPS
Hello,
We are trying to develop a mechanism to power cycle Tripp Lite UPS. When we
checked the upscmd, looks like the only command we can use is
shutdown.reboot(sudo upscmd -u user -p password ups shutdown.reboot).
Because the PC is connected to UPS directly and we would prefer shutdown PC
before power cycle the UPS. But if we run shutdown PC first it won't run
the power cycle the UPS script
2014 Jun 17
3
Question about recycle power of Tripp Lite UPS
Hello,
We are trying to develop a mechanism to power cycle Tripp Lite UPS. When we
checked the upscmd, looks like the only command we can use is
shutdown.reboot(sudo upscmd -u user -p password ups shutdown.reboot).
Because the PC is connected to UPS directly and we would prefer shutdown PC
before power cycle the UPS. But if we run shutdown PC first it won't run
the power cycle the UPS script
2019 Dec 31
2
Tripp Lite INTERNET750U instant commands ?
Hello List members,
Are there any other commands available for this UPS, I've been searching
without success...
I know I use an old UPS, and when I do: "upscmd -l pbx at 192.168.1.18" for
instance, I get the answer: "Instant commands supported on UPS [pbx]:
shutdown.return - Turn off the load and return when power is back"
If I send this command it works, shutdowns
2014 Jun 18
0
Question about recycle power of Tripp Lite UPS
[moving this to nut-upsuser, since other users of Tripp Lite equipment may have specific experience with this.]
On Jun 17, 2014, at 7:51 PM, Shen Chuan <shen at minutekey.com> wrote:
> We are trying to develop a mechanism to power cycle Tripp Lite UPS. When we checked the upscmd, looks like the only command we can use is shutdown.reboot(sudo upscmd -u user -p password ups
2014 Jun 18
2
Question about recycle power of Tripp Lite UPS
Hello Charles,
Thank you for your comment. Just tried to use ups.delay.shutdown to
postpone the UPS shutdown. The thing is that if the PC shutdown first, then
the UPS, it wasn't able to send "shutdown.reboot" any more because
everything is power off after the UPS shuts down.
Also play on the watchdog for Tripp Lite. Looks like it has the command of
reset.watchdog but not
2020 Jan 04
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
After a quick glance, it looks like that older version of the INTERNET750U supports only a few controls Shutdown of the inverter, cancelling that shutdown, setting the delay for the shutdown timer, and enabling/disabling a USB watchdog function.
My *guess* is that Network UPS Tools is just exposing the shutdown command as one command.
Does that help?
Note to users with the same model but
2020 Jan 01
0
[EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Thanks. Looks like an older SKU, so I'll look into it when I am back in the office later this week.
________________________________
From: Jean-Roch Blais <blaisjeanroch at gmail.com>
Sent: Tuesday, December 31, 2019 8:04:34 PM
To: David Zomaya
Cc: nut-upsuser at alioth-lists.debian.net
Subject: Re: [EXTERNAL] [Nut-upsuser] Tripp Lite INTERNET750U instant commands ?
Hello List, David:
2020 Jan 04
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Thank's David, really appreciate your answer, and your time. Just a yes or
a no, can I upgrade the firmware on this UPS ?
Cheers
jrb
On Fri, Jan 3, 2020, 19:06 David Zomaya, <David_Zomaya at tripplite.com> wrote:
>
> After a quick glance, it looks like that older version of the INTERNET750U
> supports only a few controls Shutdown of the inverter, cancelling that
>
2014 Jul 01
2
The dreaded Tripp Lite SMART500RT1U and NUT
Hello Charles,
Thank you for all of your help this far. I have made some great
progress. I was hung up with all sorts of USB problems which we can
chalk up to a "blonde moment" for me (or more accurately, a *bald*
moment). In all my starting over and screwing around, I had forgotten
to reinstall libusb-compat. Duh! I am now to a point that I think we
can dig a little deeper.
The
2015 Mar 11
0
nutdrv_atcl_usb
2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at gmail.com>:
> Would you be so kind and provide some examples (commands), please?
> I would run them today in the evening and report back with the logs.
First, be sure to have in upsd.users a valid entry to set vars and
execute instant commands:
[<username>]
password = <password>
actions = SET
instcmds = ALL
where
2020 Jan 04
2
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Hi Jean-Roch,
No. There is no user-facing firmware update process available.
If there are any particular commands you're interested in on a newer unit, I can look them up.
________________________________
From: jean-roch blais <blaisjeanroch at gmail.com>
Sent: Friday, January 3, 2020 6:13 PM
To: David Zomaya
Cc: nut-upsuser at alioth-lists.debian.net
Subject: Re: [POSSIBLE FRAUD] Re:
2006 Oct 13
2
Tripp-Lite OmniVS1500XL
All,
I recently purchased a Tripp-Lite OmniVS1500XL and am running NUT on a
Centos-based system.
Based on the compatibility list I specified the tripplite_usb driver.
When I query the unit I get:
[root@chryxus ~]# upsc UPS@localhost
battery.voltage.nominal: 24
driver.name: tripplite_usb
driver.version: 2.0.3-pre2
driver.version.internal: 0.6
input.voltage.nominal: 120
2018 Jan 12
2
Tripp-Lite BCPERS450 shutdown/restart problems
From: Charles Lepple <clepple at gmail.com>
Date: Thu, 11 Jan 2018 22:31:54 -0500
The trick will be adding support for this without breaking other
models.
For whatever it's worth, Tripp lite's software does not display the
model number anywhere, so it may be treating all models the same.
In case you are interested, this mapping between the "Path" and the
2020 Jan 04
0
[POSSIBLE FRAUD] Re: [EXTERNAL] Tripp Lite INTERNET750U instant commands ?
Ok thank's for your time David, the PSUs, I have two old ones, are working
very well. I simply put in new batteries and on they go :-). I'm using the
PSUs mostly to secure my Raspberry PIs, which are notorious to fail (SD
card) on power failures. Bye, jrb.
On Fri, Jan 3, 2020 at 7:35 PM David Zomaya <David_Zomaya at tripplite.com>
wrote:
>
> Hi Jean-Roch,
> No. There is no
2015 Mar 11
3
nutdrv_atcl_usb
Thank you for the commands...
Please find attached log...
Im not sure if the Load.on worked, because in the end I had to manually
start the UPS (with button).
Anyway, let me know should I need to perform some steps again (probably
yes, since I believe it was off).
Jakub
On 11.03.2015 20:11, hyouko at gmail.com wrote:
> 2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at
2007 May 25
0
Patch -- SVN revision in the version string
This is the patch to include SVN revision level in version number displays.
There should be two enclosures; the patch itself and a new source file.
common/upsversion.c.
upversion.c defines a single function. upsversion(), that returns a version
string for display. Some Makefile trickery ensures that this file will
be recompiled whenever the project's SVN revision level has changed since
it
2013 Sep 04
2
[HCL] Forza FX-1500LCD supported by blazer_usb
Gabor: note, these HCL reports go to the nut-upsdev list.
Begin forwarded message:
> From: Gabor Tjong A Hung
> Subject: Re: Network UPS Tools - Compatibility List
> Date: September 3, 2013 2:18:31 PM EDT
>
> Sorry,
> I just noticed the "If your device isn?t listed" part:
>
> [HCL] Forza FX-1500LCD supported by blazer_usb
>
>
> [root at freenas] ~#