similar to: APC UPS: replacement battery always triggers shutdown

Displaying 20 results from an estimated 4000 matches similar to: "APC UPS: replacement battery always triggers shutdown"

2013 Jan 13
0
APC UPS: replacement battery always triggers shutdown
Arnaud, I was finally able to get back to this issue and would recommend adding these items to the FAQ #37 about recalibrating the UPS: 1a. It's important that the UPS be at 100% charge before starting the procedure; starting at lower will not work at all, not just produce inaccurate numbers. ? ? ? [I started the procedure when the UPS was at 91% charge. After that it would never report
2014 May 02
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
Hi, I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, with nut-2.2.1. Ubuntu system uses ASUS motherboard. On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports. I've tested ports by connecting them with a null-modem cable and running cu in 2 terminals. Type in one terminal, output shows
2014 May 03
0
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote: > Hi, > > I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. > > I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, > with nut-2.2.1. Ubuntu system uses ASUS motherboard. > > On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports. > I've tested ports by connecting
2014 May 03
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 3, 2014, at 5:20 AM, Charles Lepple wrote: > On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote: > >> Hi, >> >> I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. >> >> I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, >> with nut-2.2.1. Ubuntu system uses ASUS motherboard. >> >> On mini-ITX system, I
2010 Mar 26
2
apcupsd, APC UPSs, and batteries, resolved
Well, here's the tale: we got a "replacement kit" for some APC SmartUPS 3000 - rackmount UPSs. The "kit", costing about half of what APC is asking, is just the batteries, and you pull the tray out, open it up, and swap out the batteries. Except, I did this on one... and the replace battery light never went out. Not using apcupsd's apctest, not pushing the button. The
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there, I am using an old (really old) APC Smart-UPS 600. It worked fine under apcupsd but when I tried NUT it did not work. The error I was getting was: sudo /lib/nut/apcsmart -DDD /dev/ttyS1 Network UPS Tools (version 2.0.4) - APC Smart protocol driver Driver version 1.99.8, command table version 2.0 debug level is '3' Attempting firmware lookup Firmware: [D4] Not found in
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi Arnaud, > Hi Thomas, > I just checked the 2.4.1 version of nut and found that you forgot to add > my old UPS model (APC Smart-UPS 900). I guess it is because you were > busy at the time when I sent you the patch. So here it goes again. :) > uh, right sorry. I was pretty sure I applied
2014 Dec 04
2
Changing self test date
Hello, does any one know how to change the date of the self tests on APC UPSes ? I'd like to be able to choose the day and the hour so that it happens at office hours, in case of any problem... I've tried to do this by launching a test at a convenient time, but the self tests still occurs at the previous date and hour :-( Regards. -- Frantz de Germain D?partement Informatique UFR
2010 Jan 08
3
USB problems on 8.0-STABLE
I am having problems with mouse, keyboard and APC UPS. When attempting to start apcupsd I get the following error: Jan 8 17:42:06 Ace apcupsd[1606]: apcupsd FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device -- For a link to detailed USB trouble shooting information, please see <http://www.apcupsd.com/support.html>. Jan 8 17:42:06 Ace apcupsd[1606]: apcupsd error shutdown
2014 Dec 04
0
Changing self test date
On Dec 4, 2014, at 5:30 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote: > Hello, > > does any one know how to change the date of the self tests on APC UPSes ? I'd > like to be able to choose the day and the hour so that it happens at office > hours, in case of any problem... > > I've tried to do this by launching a test at a convenient time, but
2023 Nov 24
1
APC Modbus support is finally here!
I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Thanks in advance, Jim Klimov On Wed, Nov 22, 2023 at 3:20?PM Jim Klimov <jimklimov+nut at gmail.com> wrote: > Great! Thanks for the info, and hope the driver author can address the > nits (forwarding now...) > > Jim
2023 Nov 24
1
APC Modbus support is finally here!
I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Thanks in advance, Jim Klimov On Wed, Nov 22, 2023 at 3:20?PM Jim Klimov <jimklimov+nut at gmail.com> wrote: > Great! Thanks for the info, and hope the driver author can address the > nits (forwarding now...) > > Jim
2010 Jan 22
1
apcupsd
Here's an odd one: I installed apcupsd, and it works with most of our UPSs. I'd swear it worked on this one. Then I replaced the Gin-u-wine APC batteries, which were dead, with new ones, non-APC. They're just dumb batteries, no chips or whatever on them. If I hook it up using a serial cable, I can get info. If I hook it up the way I had it, with APC's weird USB cable - and this is
2023 Nov 27
1
APC Modbus support is finally here!
Jim Klimov <jimklimov+nut at gmail.com> > > I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Hi: I got another ups for testing. so I test the new commit for both APC SRT3000XL and SMT2200RM2U. the results below: 1. I get the new attribute "ups.test.result" for
2023 Nov 27
1
APC Modbus support is finally here!
Jim Klimov <jimklimov+nut at gmail.com> > > I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Hi: I got another ups for testing. so I test the new commit for both APC SRT3000XL and SMT2200RM2U. the results below: 1. I get the new attribute "ups.test.result" for
2013 Feb 28
8
false low battery alarm
Hi, I have two types of UPS devices and one of them (APC) gave me a false "low battery" alert. I can't reproduce the problem... Also, there was nothing apparently wrong with the UPS at the time of the false alert. All I could do was grab the driver values within a minute after the "low battery" notification. These are the values: battery.runtime.low : 120
2017 Apr 26
0
APC Back-UPS XS1300 battery behaviour on test shutdown
Hi there, Seeing an odd behaviour when running upsmon -c fsd to test my Raspberry Pi (running Jesse Lite) setup as a upsmon master, attached via USB to an APC Back-UPS XS1300. The Raspberry Pi is plugged into the Master outlet on the APC. The UPS clicks onto battery (and the fan spins up) for a few minutes, then resets, then repeats again, while finally remaining on AC power afterwards. The
2013 Jun 07
1
cannot update battery.date value of APC ups battery
Hi, I'm running this command: # upsrw -s "battery.date=2013Jun7" -u ups-mon-IT "IT-APC-BOTTOMRIGHT at 127.0.0.1" Password: OK but I'm getting this listing: # upsc IT-APC-BOTTOMRIGHT at 127.0.0.1 battery.alarm.threshold: 0 battery.charge: 100.0 battery.charge.restart: 15 battery.date: 01/10/06 battery.packs: 000 battery.runtime: 1440 battery.runtime.low: 120
2015 Dec 06
2
APC Back-UPS 950 Battery Connector
Hello, I just buy a new UPS, the APC Back-UPS 950. In the back side it has a yellow plug that say "Battery Connector". If I connet it, the UPS works well, it switch on the green light "On Line". If I unplug ot it start to beep and it switch on the red light "Replace Battery". Need I plug the "Battery Connector"? Thanks and regards. -------------- next
2015 Dec 08
0
APC Back-UPS 950 Battery Connector
On Dec 6, 2015, at 3:32 AM, Josu Lazkano <josu.lazkano at gmail.com> wrote: > > Hello, > > I just buy a new UPS, the APC Back-UPS 950. > > In the back side it has a yellow plug that say "Battery Connector". > > If I connet it, the UPS works well, it switch on the green light "On Line". If I unplug ot it start to beep and it switch on the red