similar to: bcmxcp_usb: multiple UPS

Displaying 20 results from an estimated 800 matches similar to: "bcmxcp_usb: multiple UPS"

2007 Apr 20
2
Multiple UPS monitoring, relaying
Hello, I've got a setup with NUT, where we've got two UPSes, ups1 and ups2. UPS1 supports our servers, while UPS2 supports our desktop boxes. We monitor both of them via USB on a box now called "upsmon". The interesting point comes here. We monitor both UPSes on the upsmon box, but if UPS2 fails, which supports our desktop boxes, NUT shouldn't initiate a shutdown in
2017 Dec 04
2
SNMPv3 fails when more than one UPS is configured in ups.conf
Hi Charles, Running upsdrvctl -D start on the host with all three configured to SNMPv3 kicks out 56 different "unhandled ASN 0x81 from ..." lines on all three but importantly they all start up and keep running. I'm starting to suspect the startup is taking so long that systemd is timing out and killing it. time -p reports real time of 133.27. I'm not a fan of systemd but
2017 Nov 30
2
SNMPv3 fails when more than one UPS is configured in ups.conf
New NUT install dealing with three APC Smart-UPS 5000s, two of which have AP9617 and the third has a AP9619 card. The SNMPv3 configurations on all three are exactly the same. This is confirmed by snmpget calls that work just fine: snmpget -Cf -v3 -u [...] -l authPriv -A '[...]' -X '[...]' -a MD5 -x DES [upsname] .1.3.6.1.4.1.318.1.1.1.1.1.1.0 snmp-ups can query all three
2012 Mar 04
2
NUT Two Apc UPSes on Windows
Hi, I've got a question about managing two UPSes under NUT. I have two similar model APC usb-connected UPSes to work with, but don't know how to manage them simultaneously from under Windows. Long story short, my ups.conf looks like this: --- ups.conf --- [ups1] driver= usbhid-ups port= auto serial=AS1054340323 [ups2] driver= usbhid-ups port= auto serial=AS1026662626 ---
2005 Dec 24
1
Regular expressions in upssched.conf?
Hi, I didn't found an answer for my question in NUT documentation/FAQ or this mailing list archive so I?m posting it here. I want to start a timer only if both of my UPSes remain on battery. Not just one, both. My UPSes are: - ups1@host-a - ups2@host-b Is it possible to use something like this in upssched.conf? AT ONBATT ups1.* && ups2.* START-TIMER onbattwarn 180 Thanks,
2007 Apr 12
1
APC 1500 USB problem
Hello, We have two APC Back-UPS RS 1500 USB stuff, and i've got a bit of a problem with it and NUT. The usbdevs output: addr 2: Back-UPS RS 1500 FW:8.g8 .I USB FW:g8, American Power Conversion addr 3: Back-UPS RS 1500 FW:8.g8 .I USB FW:g8, American Power Conversion (UPS1 and UPS2) I've configured our NUT system to monitor the UPSes, and it went very fine till the time had arrived for a
2009 Nov 15
3
two MGE Ellipse 1500 ups via usb
Hi, I've got two MGE Ellipse 1500 UPS connected via usb to an ubuntu jaunty system with nut and libupsclient1 2.4.1-2ubuntu4. As soon as I start the driver for the second one, they start fighting each other and I get no data. I found an older post to this list that said: If you want to monitor multiple UPSes through usbhid-ups, you *must* make sure that each one can be uniquely identified
2025 May 12
1
Questions about failover architecture
Hello Jim, I am following the direction of the `clone` drivers, although using the modern `upsdrvquery.c` API. Essentially I am parsing the protocol lines directly reading from the driver sockets, as the clone drivers do. As for ups.conf, I start up as follows without problems: [ups] driver = dummy-ups port = /etc/nut/5E.dev [ups2] driver = dummy-ups port = /etc/nut/APC.dev [failover] driver
2025 May 12
2
Questions about failover architecture
P.S. To articulate better what I am unclear about from your message: `nutshutdown` seems to run `@SBINDIR@/upsdrvctl shutdown`. >From my understanding, this would command - all - `ups.conf` UPS to shutdown. So this would already include the UPS monitored by any failover/multiplexing driver. In contrast, `upsdrvctl shutdown` would start up all these drivers again, respectively. What kind of
2007 Dec 01
1
APC smartups 1500 is broken with usbhid-ups
I'm trying to setup a server controlling 8 ups, 6 APC Smartups 1500 and two 1000. Because of the number of ups, i connected them using usb cables. I'm using Debian Etch AMD64 and nut 2.2.0 from testing (already tried 2.0 from stable, but had problems reading the ups serials and all the following problems of 2.2). This is my ups.conf: [ups2] driver = usbhid-ups port =
2025 May 12
1
Questions about failover architecture
Sounds great, thanks for the update! For communications with the other drivers (from failover or multiplexor), I suggest using the local driver socket line the clone* drivers do: this removes a dependency on `upsd` both for the service startup (no chicken-and-egg issue of drivers before upsd, but upsd before the failover driver) and for FSD end-game (after all services stopped, we just need to
2025 May 12
1
Questions about failover architecture
Hello again, I can report back that my failover driver is progressing nicely, and a lot of things seem to overlap with what could very well also be useful and maybe used eventually for a future multiplexing driver. Basically, my failover logic takes driver names (sockets) in comma-separated form from the `port` variable and keeps track of these drivers, monitoring their information and failing
2025 May 12
1
Questions about failover architecture
Good point, I guess I thought it knew which UPSes are getting the FSD treatment. Maybe this should also get revised eventually (e.g. a "primary" monitoring system not fed by the UPS it is wired to should never FSD itself due to the outage, but should ensure that UPS gets powered off or power-cycled when no "secondary" clients remain). Then maybe not much is needed at this
2025 May 12
1
Questions about failover architecture
Thinking of it, the service-aware nut-driver-enumerator script has ways to set dependencies of a driver on other units in the system, depending on driver type. A couple of lines added there would be useful to ensure the failover/multiplex driver(s) start after the "real" driver units they scrape data from, and it would be a "soft" dependency (real driver unit may crash without
2019 Dec 25
1
NUT not shutting down one of three UPSs (sometimes none of them shut down)
I have three APC SmartUPS 5000s. Two of them are AP9617 and one is AP9619. I have a RS-232 connections from my monitor host to all three. All three report status and give information. One of the two AP9617 - ups3-1 - does not shut down when FSD is sent. It did when I first set this system up a year or two ago but it's stopped doing so since then. Resetting the management interface does not
2012 Oct 04
1
APC Smart-UPS 1200
Hi. Is the subject UPS model supported? I believe so, but I don't have a unit to test with. Any comments on this model? I'm trying to advise a colleague. Thank you, as always. T: Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#= 3 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=051d ProdID=0003 Rev= 1.06 S: Manufacturer=American Power
2012 Jan 25
1
A patch to add a command to get client information
Hello!! I'm a sysadmin at La Laguna University in Spain. We are using NUT to manage our UPS with great success, but we miss a feature and we would like to send this patch to you. If you apply this patch running upsd -c info you'll get information about client connections in syslog. This is very simple and helpfull if you have hundreds of servers connected to the same upsd. Thank you for
2012 Jun 10
3
SNMP agent for NUT
Hello guys, I was some years ago when I sent something to this list. NUT is a great tool but lacks SNMP management. It can access a device using SNMP but I found no way to read NUT values using SNMP. It would be very useful in order to integrate with network management software based on SNMP. As I did not find a solution, I wrote it myself. I wrote a MIB file and a SNMP agent for net-snmp
2012 Jun 10
3
SNMP agent for NUT
Hello guys, I was some years ago when I sent something to this list. NUT is a great tool but lacks SNMP management. It can access a device using SNMP but I found no way to read NUT values using SNMP. It would be very useful in order to integrate with network management software based on SNMP. As I did not find a solution, I wrote it myself. I wrote a MIB file and a SNMP agent for net-snmp
2011 Jul 26
0
[RFC] PowerChain: add LIST POWERCHAIN and GET POWERCHAIN to the client (network) protocol
Hi, this is the 2nd part of the PowerChain RFC. 2011/6/13 Arnaud Quette <aquette.dev at gmail.com> > As already presented, the links below will describe in details the > PowerChain notion: > > https://wiki.ubuntu.com/ServerOneiricInfraPower > https://wiki.ubuntu.com/ServerOneiricInfraPower#PowerChain%20design >