Displaying 20 results from an estimated 200 matches similar to: "reference docs"
2009 Jun 09
4
[PATCH] btrfs: fix write_dev_supers
Hi.
I got following BUG trace.
This is violation of BUG_ON(!buffer_locked(bh)) check on submit_bh() function.
In write_dev_supers(), if wait parameter is set and buffer_uptodate() check
is negative, submit_bh() is executed and hit above BUG_ON.
So I fixed this issue.
Thanks.
Jun 9 00:41:32 dl580 kernel: ------------[ cut here ]------------
Jun 9 00:41:32 dl580 kernel: kernel BUG at
2012 Aug 30
0
Can't join Samba as DC to existing Win2k3 Domain
I downloaded and built Samba 4, and I'm at the step where I'm trying to add it
to the domain and I'm getting a replication error when it's trying to do it's
initial replication.
bin/samba-tool domain join domain.coop DC -Uusername --realm=domain.coop
Finding a writeable DC for domain 'domain.coop'
Found DC DC.domain.coop
Password for [DOMAIN\username]:
workgroup is
2007 May 25
3
adddriver issue
I'm trying to adddriver using rpcclient but this error happens:
ERROR: string overflow by 1 (1024 - 1023) in safe_strcpy [adddriver "Windows NT
x86" "HP LaserJet 4250 PCL5e]
The "server properties" add driver button is disable.... yes, I'm print operator:
printserver:~ # net rpc rights list "DOMAIN\user" -Uroot -Wprintserver
Password:
2006 Jul 14
1
testing a 2000 queues print server with smbtorture
Hi everyone,
I'm very interested in samba testing subject. Because I need to plan a
samba/cups/linux 2000 queues print server migration from W2K. But before that, I
wanted to generate the service load before listen users claiming the server is
running under a low performance. Somebody knows a good test set to simulate
printing share connections from clients in my print server using
2007 Nov 07
2
tdb search optimization
I'm running:
# smbd -V
Version 3.0.24-2.28-1354-SUSE-CODE10
In a 600 print queues print server, but I'm experiencing a low performance while
using the first queue. I was attaching ltrace/strace to some processes with "use
mmap=no" and I found a BIG difference in information gathering in ntprinters.tdb
between the first and the last print queue (using alphabetical sorting).
This
2006 Mar 17
1
print server performance issues
I'm migrating a 1.000 queues windows print server with AD very critical
enviroment to linux/cups/samba solution. Initially, everything working fine, but
when reached paroximately 400 queues created the server is getting degradated.
The browsing of printers shares is very low. Many times during the day smbd and
winbindd need to be restarted to stop the degradation. I didn't found any
2006 Nov 01
1
Windows != Samba - NETBIOS name handling
Hi,
I'm using samba just for its "net join" functionality. Computer accounts and kerberos keytabs are
created by Samba in Active Directory via "net ads join", then used by UNIX clients to authorise and
authenticate via LDAP and Kerberos.
Samba works perfectly until the computers hostname is longer than 15 characters. Then any attempt to
join the domain fails with:
----
2006 Jul 27
2
trust domain list
Hi everybody.
When using the command:
# net rpc trustdom list
what is the difference in output between:
The "trusted" domains list and "trusting" domains list?
Which operations are performed in both actions?
My example:
net rpc trustdom list
Trusted domains list:
DOMA S-1-5-21-790525478-1844823847-725345543
DOMB
2015 Oct 07
2
OT hardware issue: HP controller to 3rd party RAID
John R Pierce wrote:
> On 10/7/2015 1:30 PM, m.roth at 5-cent.us wrote:
>> No. I'm the one who got the quote and set up the order for my managers,
>> and I know what it's got: the ethernet connection is to the internal
>> webserver to manage the RAID. the 712S I have is dual-path SAS for data.
>
> then yeah, you'll need a plain SAS2 external HBA card. If
2015 Feb 10
0
KISS networking with CentOS 7
Le 10/02/2015 17:20, m.roth at 5-cent.us a ?crit :
> Please explicate - offlist is fine. I really dislike the naming
> convention.... I was installing on a new HP dl560 g8, and it came up with
> ensf1 (which is*great* fun if you're trying to do a pxeboot build....)
The CentOS FAQ explains how to restore the traditional naming scheme:
2015 Feb 10
3
KISS networking with CentOS 7
On Tue, Feb 10, 2015 at 05:24:53PM +0100, Niki Kovacs wrote:
> Le 10/02/2015 17:20, m.roth at 5-cent.us a ?crit :
> >Please explicate - offlist is fine. I really dislike the naming
> >convention.... I was installing on a new HP dl560 g8, and it came up with
> >ensf1 (which is*great* fun if you're trying to do a pxeboot build....)
>
> The CentOS FAQ explains how to
2005 Apr 17
0
running winword under wine from an existing windows installtion
Hi,
I have just built wine from source(by running
wineinstall as root). I
have two windows partitions mounted to different
directories in my
linux setup. Wine detected these during wineinstall:
***************************************************************
Windows was found on your system, and so we can use
the Windows
Drive as our Wine drive. You may, however, wish to
create a clean
Wine
2009 Jan 06
2
cluster member hangs during reboot
Hi All,
I inherited a 4-node ocfs2 cluster and recently 2 ocfs2 filesystems were added to be use as temp tablespace.?One of the four nodes rebooted during the ?creation of the tablespace and hanged at the message below...and it just sits there. If I put the server into rescue mode and comment out all the filesystems it boots up fine and than I can mount the ocfs2 filesystem manuelly but it cannot
2004 Dec 05
3
64bit and 32 bit
Dear all...
Currently I am having 5 RAC nodes with Configurations as below :
1. HW = DL580 32 Bit Processor
2. OS = RHAS 2.1
3. OCFS= Latest Version
4. RAC= Oracle9i 9.2.0.5 (32 Bit)
Now I am planning to add 2 more Rac Nodes in the existing RAC:
1. HW=Itanium 64 bit processor
2. OS=RHAS 3.0
3. OCFS=Latest Version
4. RAC=Oracle9i 9.2.0.5 (32 bit)
Can I
2013 Sep 05
3
Getting a do_IRQ: xx.xxx No irq handler for vector (irq -1), any ideas?
I setup a CentOS 6 server to use with KVM/QEMU, and I am getting the
following error a good bit, granted it doesn't seem to be causing any
trouble. I figured I would post and see if anyone has any ideas on the
issue, or if I can just dismiss it.
If I look at my logging/dmesg, I see:
do_IRQ: 19.217 No irq handler for vector (irq -1)
do_IRQ: 3.178 No irq handler for vector (irq -1)
do_IRQ:
2007 Dec 17
0
Workaround for ACL and file attributes
Just thought I'd post a simple workaround for Windows ACL's and file
attributes for rsync. Using some basic scripting will allow ACL information
to be stored for future use on files transferred using rsync. Most will
probably find the information worthless but thought I'd post it anyway.
- To get ACL information, use the icacls program provided as part of Server
2003 SP1
2013 Apr 30
3
flashing a BIOS on an HP server
Hi, folks,
Since I've gotten a total of one response in days on the HP forum,
maybe the collective mind here has an answer.... As I've mentioned in
other posts, we have an HP dl580 g5 that started throwing ECC errors.
But wait, it's worse: memory is mirrored.... And the thing is fully
populated with 32 DIMMs.
I took my best guess, pulled the matching set of DIMMs, and took two
2011 Aug 17
5
facter-1.6.0 incorrectly identifies hardware node as virtual
I''ve installed facter-1.6.0 and puppet-2.7.3 on a number of SLES 10
hardware nodes (HP DL580) running the Virtuozzo hosting software.
Well, facter correctly identifies such a machine as a hardware node
("virtual => openvzhn") but somehow concludes that the hardware node
is in fact virtual. ("is_virtual => true")
This breaks some rather important logic. If
2015 Oct 26
3
semi-OT: HW
Running CentOS 6.7, on an older HP DL580 G5. We've got a Dell 12-bay RAID
box plugged into a PERC H800 (aka LSI Liberator) that we put in the HP,
and that works fine. We've got a new RAID (a JetStor), and are trying to
plug it in.
The layout is that the Dell RAID is dual-pathed DAS. Each PERC has two DAS
ports. We've got the Dell RAID in the top port of each PERC. I *thought* I
could
2013 Apr 24
3
DIMM problem
Hey, folks,
I've got an HP Proliant DL580 G5 throwing ECC errors. This is annoying,
since a) it's all new as of a few months ago, and b) it's *fully*
populated. The two things I need to figure out are a) *which* DIMM it
is, and b) is it mirrored; if so, which *other* DIMM needs to come out
until we get replacements from the OEM.
Here's one of many, all identical, from dmesg: