Displaying 20 results from an estimated 10000 matches similar to: "was, PATA Hard Drive woes, is "SMART""
2010 Oct 31
4
PATA Hard Drive woes
Hi All.
Yesterday I was installing Centos 5.5 to my web server, and
it looks like the main hard drive has gone AWOL.
Fedora 12 put the file system into r/o mode.
The drive is an Hitachi, still under warranty.
There are bad sectors on it, and running the Hitachi DFT
tool confirms this. Also I cannot repair the bad sectors.
Would this be caused by a faulty I/O chip, or is it safe to
say
2010 Sep 19
2
GRUB woes: GRUB Hard Disk Error
Hello all,
I am attempting to install CentOS 5.5 on a recently donated home server (was
Windows). I've tried installing twice; first, separating /boot, swap, /,
/var, /usr and /home into different partitions, the second time choosing
default layout. Both times have resulted in "GRUB Hard Disk Error" upon
boot.
About the hard disk, it is a Seagate SATA drive. I do not have another
2010 Dec 20
3
Resilvering - Scrubing whats the different
Hello All
I read this thread Resilver/scrub times? for a few minutes
and I have recognize that I dont know the different between
Resilvering and Scrubing. Shame on me. :-(
I dont find some declarations in the man-pages and I know the command
to start scrubing "zpool scrub tank"
but what is the command to start resilver and what is the different?
--
Best Regards
Alexander
Dezember, 20
2008 Aug 03
1
Scrubbing only checks used data?
Hi there,
I am currently evaluating OpenSolaris as a replacement for my linux installations. I installed it as a xen domU, so there is a remote chance, that my observations are caused by xen.
First, my understanding of "zpool [i]scrub[/i]" is "Ok, go ahead, and rewrite [b]each block of each device[/b] of the zpool".
Whereas "[i]resilvering[/i]" means "Make
2007 Mar 05
3
How to interrupt a zpool scrub?
Dear all
Is there a way to stop a running scrub on a zfs pool? Same question applies to a running resilver.
Both render our fileserver unusable due to massive CPU load so we''d like to postpone them.
In the docs it says that resilvering and scrubbing survive a reboot, so I am not even sure if a reboot would stop scrubbing or resilvering.
Any help greatly appreciated!
Cheers, Thomas
2006 Nov 03
27
# devices in raidz.
for s10u2, documentation recommends 3 to 9 devices in raidz. what is the
basis for this recommendation? i assume it is performance and not failure
resilience, but i am just guessing... [i know, recommendation was intended
for people who know their raid cold, so it needed no further explanation]
thanks... oz
--
ozan s. yigit | oz at somanetworks.com | 416 977 1414 x 1540
I have a hard time
2009 Jul 10
5
Slow Resilvering Performance
I know this topic has been discussed many times... but what the hell
makes zpool resilvering so slow? I''m running OpenSolaris 2009.06.
I have had a large number of problematic disks due to a bad production
batch, leading me to resilver quite a few times, progressively
replacing each disk as it dies (and now preemptively removing disks.)
My complaint is that resilvering ends up
2010 Jul 05
5
never ending resilver
Hi list,
Here''s my case :
pool: mypool
state: DEGRADED
status: One or more devices is currently being resilvered. The pool will
continue to function, possibly in a degraded state.
action: Wait for the resilver to complete.
scrub: resilver in progress for 147h19m, 100.00% done, 0h0m to go
config:
NAME STATE READ WRITE CKSUM
filerbackup13
2011 Sep 11
8
bad seagate drive?
Hi list,
I''ve got a system with 3 WD and 3 seagate drives. Today I got an email
that zpool status indicated one of the seagate drives as REMOVED.
I''ve tried clearing the error but the pool becomes faulted again. Taken
out the offending drive and plugged into a windows box with seatools
install. Unfortunately seatools finds nothing wrong with the drive.
Windows seems to see
2005 Mar 17
0
[LLVMdev] new IA64 backend
On Fri, 2005-03-18 at 05:04 +0900, Duraid Madina wrote:
> I've just checked in an IA64 backend to LLVM!
Woo hoo! And There Was Much Rejoicing in IA64 Land :-).
--
Ciao,
al
----------------------------------------------------------------------
Al Stone Alter Ego:
Linux & Open Source Lab Debian Developer
Hewlett-Packard
2006 Oct 17
0
Winbind(?) woes after hard disk full
Hi all.
Yesterday morning, we had a problem with our Samba box (3.0.20b-SUSE),
traced to the root(/) partition becoming full. Upon restart, it was
later reported that users at another office (trusted domain), could not
access our server.
Everything had been running smoothly for over 5 months.
Running 'wbinfo -u/-g' returns a list of users/groups from the local
domain, prefixed with
2006 Dec 07
1
Asterisk 1.4.0-beta3 spandsp rxfax woes (or me being hard of thinking)
Hi,
I have installed the latest version of asterisk(1.4.0-beta3), and built
app_rxfax/txfax. I'm using spandsp from here,
http://www.soft-switch.org/downloads/snapshots/spandsp/spandsp-20061207.tar.gz
Everything builds ok. I had to manually apply the patch from the site so
configure would spot spandsp libraries. However, when I try dialing my
virtual fax extension (either from a phone or
2007 Sep 14
10
Mixing SATA & PATA Drives
I suspect it''s probably not a good idea but I was wondering if someone
could clarify the details.
I have 4 250G SATA(150) disks and 1 250G PATA(133) disk. Would it
cause problems if I created a raidz1 pool across all 5 drives?
I know the PATA drive is slower so would it slow the access across the
whole pool or just when accessing that disk?
Thanks for your input.
- Chris
2009 May 25
1
{SOLVED} Re: OT: SMART warning on hard drive, same warning for 2 1 /2 years
On Sun, May 24, 2009 at 5:10 PM, Lanny Marcus <lmmailinglists at gmail.com> wrote:
> My wife's box has a very intermittent problem, ?when booting from the
> Maxtor IDE hard drive. This has been going on for about 2 1/2
> years.... The box is a Compaq EVO D300v for the Enterprise. When it
> boots, there is a SMART advisory from the BIOS that says failure is
> immenient.
2013 Sep 21
2
Smart-UPS staying in OB after power return
Hi list,
UPS is a Smart-UPS 3000 RM (SU3000RM3U, ups.firmware 92.11.D,
ups.mfr.date 12/14/99) with brand-new batteries. NUT is 2.6.5 running
on SL6 (RHEL6 clone) from EPEL packages. 'upsc' output pasted at bottom.
I'm not very familiar with UPSs in general or this model in particular,
and it's doing things I don't expect. I have done my homework, and read
UPS user manual,
2009 Jan 28
1
Issue with drive replacement
In the process of replacing a raidz1 of four 500GB drives with four 1.5TB drives on the third one I ran into an interesting issue. The process was to remove the old drive, put the new drive in and let it rebuild.
The problem was the third drive I put in had a hardware fault. That caused both drives (c4t2d0) to show as FAULTED. I couldn''t put a new 1.5TB drive in as a replacement -
2003 Sep 25
2
The first stable release of Samba 3.0 is available
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
[ and there was great rejoicing among the masses! And a
tiny voice squeeked, "See, I told you they would get
it out before the Linux 2.6 kernel" ]
The Samba Team is proud to announce the availability of the
first official release of the Samba 3.0 code base.
Major new features:
- -------------------
1) Active Directory support.
2005 Aug 18
1
using various IDE or SCSI hard drive interfaces with CentOS Linux questions
greetings,
it has been a long time and i do not recall all the specifics
if one loads CentOS Linux on a machine with an PATA IDE or SCSI hard drive
interface then i should be able to interchange that drive on virtually _ANY_
machine with an PATA IDE or SCSI respectively right?? (ignore physical
connector differences on SCSI)
i believe the answer(s) to be yes...
now, what about the newer SATA?
2009 Jan 27
5
Replacing HDD in x4500
The vendor wanted to come in and replace an HDD in the 2nd X4500, as it
was "constantly busy", and since our x4500 has always died miserably in
the past when a HDD dies, they wanted to replace it before the HDD
actually died.
The usual was done, HDD replaced, resilvering started and ran for about
50 minutes. Then the system hung, same as always, all ZFS related
commands would just
2013 Sep 22
1
Smart-UPS staying in OB after power return
Hi Kris,
On 09/21/2013 05:11 PM, Kris Jordan wrote:
> John Morris wrote, On 9/21/2013 11:28 AM:
>> The most distressing problem is the UPS stays OB after removing and
>> reapplying utility power. When power is removed, the UPS goes OB and
>> upsmon detects the power failure no problem, reporting
>> 's0-ups0 at localhost is on battery'. But when power is