Here's an odd one: I installed apcupsd, and it works with most of our UPSs. I'd swear it worked on this one. Then I replaced the Gin-u-wine APC batteries, which were dead, with new ones, non-APC. They're just dumb batteries, no chips or whatever on them. If I hook it up using a serial cable, I can get info. If I hook it up the way I had it, with APC's weird USB cable - and this is
2014 Dec 04
0
Changing self test date
On Dec 4, 2014, at 5:30 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote: > Hello, > > does any one know how to change the date of the self tests on APC UPSes ? I'd > like to be able to choose the day and the hour so that it happens at office > hours, in case of any problem... > > I've tried to do this by launching a test at a convenient time, but
2010 Mar 02
3
Back to apcupsd
Ok, so another apc UPS 3000 complained about bad batteries, and I changed them out from the same order that I'd gotten in a couple of months ago. The APC SmartUPS 3000 started connecting and disconnecting the USB connection. I brought down and up the service, no joy. Finally, after googling, I found a *completely* undocumented way to start apcupsd, that a few years ago someone was told to
2009 Mar 28
1
APCUPSD port 3551 permission problem
I need a little help on this problem, please? I include my /etc/apcupsd/apcupsd.conf file is attached. port 3551 udp/tcp has been added to the (running) firewall. My APC is recognized as: APC Back-UPS 450 FW:844.Kld.D USB FW:Kld This from the hardware browser. PS says: root 2419 0.0 0.0 4196 584 ? Ss Mar23 0:09 /sbin/apcupsd -f /etc/apcupsd/apcupsd.conf Is group 2419 the
2010 Jan 08
3
USB problems on 8.0-STABLE
I am having problems with mouse, keyboard and APC UPS. When attempting to start apcupsd I get the following error: Jan 8 17:42:06 Ace apcupsd[1606]: apcupsd FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device -- For a link to detailed USB trouble shooting information, please see <http://www.apcupsd.com/support.html>. Jan 8 17:42:06 Ace apcupsd[1606]: apcupsd error shutdown
2014 Dec 04
2
Changing self test date
Hello, does any one know how to change the date of the self tests on APC UPSes ? I'd like to be able to choose the day and the hour so that it happens at office hours, in case of any problem... I've tried to do this by launching a test at a convenient time, but the self tests still occurs at the previous date and hour :-( Regards. -- Frantz de Germain D?partement Informatique UFR
2014 May 03
0
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
On May 2, 2014, at 3:26 AM, Kastus Shchuka wrote: > Hi, > > I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. > > I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, > with nut-2.2.1. Ubuntu system uses ASUS motherboard. > > On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports. > I've tested ports by connecting
2023 Nov 27
1
APC Modbus support is finally here!
Jim Klimov <jimklimov+nut at gmail.com> > > I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Hi: I got another ups for testing. so I test the new commit for both APC SRT3000XL and SMT2200RM2U. the results below: 1. I get the new attribute "ups.test.result" for
2023 Nov 27
1
APC Modbus support is finally here!
Jim Klimov <jimklimov+nut at gmail.com> > > I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Hi: I got another ups for testing. so I test the new commit for both APC SRT3000XL and SMT2200RM2U. the results below: 1. I get the new attribute "ups.test.result" for
2014 Dec 05
2
Changing self test date
Le Thu, 4 Dec 2014 08:42:37 -0500 Charles Lepple <clepple at gmail.com> ?crivait: > On Dec 4, 2014, at 5:30 AM, Frantz de Germain <frantz at info.univ-angers.fr> > wrote: > > > Hello, > > > > does any one know how to change the date of the self tests on APC UPSes ? > > I'd like to be able to choose the day and the hour so that it happens at >
2013 Jan 13
0
APC UPS: replacement battery always triggers shutdown
Arnaud, I was finally able to get back to this issue and would recommend adding these items to the FAQ #37 about recalibrating the UPS: 1a. It's important that the UPS be at 100% charge before starting the procedure; starting at lower will not work at all, not just produce inaccurate numbers. ? ? ? [I started the procedure when the UPS was at 91% charge. After that it would never report
2014 May 02
2
NUT + OpenBSD + dc2500cc + APC Smart-UPS SC620 = problem
Hi, I am trying to set up NUT on a mini-ITX system running OpenBSD 5.5. I have an APC Smart-UPS SC620 which runs perfectly well on Ubuntu, with nut-2.2.1. Ubuntu system uses ASUS motherboard. On mini-ITX system, I have Intel d2500cc motherboard with 4 serial ports. I've tested ports by connecting them with a null-modem cable and running cu in 2 terminals. Type in one terminal, output shows
2012 Nov 11
1
APC UPS: replacement battery always triggers shutdown
?I've been using nut on an APC Back-UPS 750 for several years with no problem, seeing the walled "UPS on battery power" messages during short 1-2 minute outages. This is connected with the original USB cable that came with the unit. After replacing the battery recently, nut always triggers a shutdown when AC power is cut off, even if only for 1 minute. I see that the data fields
2023 Nov 24
1
APC Modbus support is finally here!
I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Thanks in advance, Jim Klimov On Wed, Nov 22, 2023 at 3:20?PM Jim Klimov <jimklimov+nut at gmail.com> wrote: > Great! Thanks for the info, and hope the driver author can address the > nits (forwarding now...) > > Jim
2023 Nov 24
1
APC Modbus support is finally here!
I believe some fixes were applied to the branch since your report (most visibly, about battery time settings), are you in position to test how it behaves now? :) Thanks in advance, Jim Klimov On Wed, Nov 22, 2023 at 3:20?PM Jim Klimov <jimklimov+nut at gmail.com> wrote: > Great! Thanks for the info, and hope the driver author can address the > nits (forwarding now...) > > Jim
2023 Nov 27
2
APC Modbus support is finally here!
Thanks again, Great to see confirmations of more and more things working! > I wonder what's the fastest method to test the function (previously I setup the ups and unplug the utility from the ups for testing). > is "upsrw driver.flag.allow_killpower=1" then "upscmd driver.killpower" the correct testing procedure? At least by intent of this new feature -- yes.
2023 Nov 27
2
APC Modbus support is finally here!
Thanks again, Great to see confirmations of more and more things working! > I wonder what's the fastest method to test the function (previously I setup the ups and unplug the utility from the ups for testing). > is "upsrw driver.flag.allow_killpower=1" then "upscmd driver.killpower" the correct testing procedure? At least by intent of this new feature -- yes.
2017 Nov 17
2
semi-OT:apcupsd
> Am 17.11.2017 um 17:36 schrieb m.roth at 5-cent.us: > > wwp wrote: >> On Fri, 17 Nov 2017 10:34:53 -0500 Digimer <lists at alteeve.ca> wrote: >> >>> On 2017-11-17 10:16 AM, m.roth at 5-cent.us wrote: >>>> I can't seem to find apcupsd for C 6. Just went to epel's website, and >>> not >>>> visible. Anyone have a clue?
2017 Nov 17
3
semi-OT:apcupsd
Hello, On Fri, 17 Nov 2017 10:34:53 -0500 Digimer <lists at alteeve.ca> wrote: > On 2017-11-17 10:16 AM, m.roth at 5-cent.us wrote: > > I can't seem to find apcupsd for C 6. Just went to epel's website, and not > > visible. Anyone have a clue? > > > > mark > > I can't speak to epel, but we have copies of it if that helps you; >
2010 Jan 27
2
Feature Request: APCUPSD Support
Hi, We use Nexenta which has recently implemented a UPS plugin using NUT code. The one problem is that it can't look at APCUPSD servers for APC information. We have a UPS per a rack and a APCUPSD server per a UPS. Without this functionality, we would have to be directly connected to the UPS's for our SAN and we can't do that. Do you have a workaround or something we can do