similar to: powerware plus 5xx / fiskars 9x00

Displaying 20 results from an estimated 600 matches similar to: "powerware plus 5xx / fiskars 9x00"

2008 Dec 23
2
Exide NetUPS SE (aka Powerware 5119 etc)
My UPS is an Exide NetUPS SE PRC1500i (1500 VA), also known as Powerware 5119, according to Karl Schmidt (http://lists.alioth.debian.org/pipermail/nut-upsuser/2005-July/000026.html) also Deltec PowerRite Pro II, and according to http://www.usedups.de/compaq_ups.html also Compaq R3000h. I am not sure if the information in http://www.bps.hu/powerware/model_en.html is to be interpreted as that it was
2008 Dec 23
2
Exide NetUPS SE (aka Powerware 5119 etc)
My UPS is an Exide NetUPS SE PRC1500i (1500 VA), also known as Powerware 5119, according to Karl Schmidt (http://lists.alioth.debian.org/pipermail/nut-upsuser/2005-July/000026.html) also Deltec PowerRite Pro II, and according to http://www.usedups.de/compaq_ups.html also Compaq R3000h. I am not sure if the information in http://www.bps.hu/powerware/model_en.html is to be interpreted as that it was
2014 Nov 03
0
RFC: new variable battery.status (was: [PATCH] upscode2: Report ABM Status)
Hi, Am 13.02.2012 um 18:58 schrieb Arnaud Quette: > 2012/2/6 thomas schorpp <thomas.schorpp at googlemail.com>: >> Hi, > > Hi Thomas, > >> I want the driver report the battery status from ABM charging controllers >> -patch attached- : > > For now, I've tracked your patch here: >
2012 Feb 13
3
RFC: new variable battery.status (was: [PATCH] upscode2: Report ABM Status)
2012/2/6 thomas schorpp <thomas.schorpp at googlemail.com>: > Hi, Hi Thomas, > I want the driver report the battery status from ABM charging controllers > -patch attached- : thanks for your patch. since it introduces a new variable (battery.status.abm), I prefer to step back and think to something useful more widely. thus, I'm thinking about a generic
2005 Oct 31
2
3phase progress?
Hi all! I've been (very) out of the loop for a while, up to the point that I had completely missed that the mailing list has moved. Oh well. However, Kjell Claesson poked at me regarding the 3phase stuff, so I found out that I had missed the recent events. In any case, it seems that the situation is unchanged regarding 3phase support. As some of you remember I made a suggestion for a
2007 Dec 05
0
jbus/modbus UPS?
Hi, does anyone have any experience with UPSes managed with modbus/jbus protocol? I have a Socomec/Sicom Masterys MC unit, that is equipped with both RS232 and RS485 interfaces and, according to manual, supports JBUS-P and JBUS-PH protocols. I'd like to get some basic monitoring working, but I don't even know where to begin. Regards, -- Sebastian Zagrodzki Dzia? Sieciowy ICM,
2014 Nov 04
2
RFC: new variable battery.status
THANKYOUTHANKYOUTHANKYOUTHANKYOU!!!!!! There was a smaller patch posted to the list for lines -1389,9 +1390,10 a couple years ago, it helped some - BUT - it was still buggy. I have a Compaq R3000, I will get this patch integrated pronto and test Note that since the UPS relies on the voltage from the battery pack to determine state of charge, it is quite useful to add in the battery pack
2013 Sep 22
1
Question on weird output from a Compaq R3000
Hi All, I put my Compaq R3000 UPS on NUT. Every once in a while the battery alarm light turns on, on the front of the UPS. Maybe once every couple of days or so. When that happens I get the following output in /var/log/messages: Sep 22 01:51:46 mail upscode2[90734]: Unknown response to UPDS: .20 MOUL1 Sep 22 01:51:46 mail upscode2[90734]: Unknown response to UPDS: 0119.20 MOIL1 Sep 22
2014 Feb 19
3
Logic problem in NUT with upscode2 driver
Hi All, I have what is probably a 12 year old (or older) Compaq R3000 UPS plugged into a FreeBSD 8 system running NUT version 2.6.5 This UPS contains a total of 16 batteries in 2 banks of 8, each battery is 6 volts and the bank produces 50 volts. The UPS monitors battery voltage and the battery charger in the UPS works like this. For about 2 days it will apply a charge/float/topping
2009 Jan 29
1
Fwd: upscode2.c
----- Doorgestuurd bericht van dkbrig at gmail.com ----- Datum: Thu, 29 Jan 2009 11:16:06 -0600 Van: Danny <dkbrig at gmail.com> Onderwerp: upscode2.c Aan: adkorte-guest at alioth.debian.org Hi, I apologize if you are not the correct person, but I was wanting to submit a bug report for the upscode2.c driver but could not find a way to do that from the NUT website.
2014 Feb 20
0
Logic problem in NUT with upscode2 driver
On Feb 19, 2014, at 12:50 PM, Ted Mittelstaedt wrote: > Worse, however, is if there's a power failure right near the end > of the 2-days-off cycle. That happened to me last week - it was a > short duration 15 second loss - and the upscode2 driver decided it needed to issue a forced shutdown. > > Very likely this was because upscode2 had decided the batteries > were
2014 Nov 04
0
RFC: new variable battery.status
Hi Ted, Am 04.11.2014 um 04:12 schrieb Ted Mittelstaedt: > > Note that since the UPS relies on the voltage from the battery pack to > determine state of charge, it is quite useful to add in the battery pack > voltage to the logs as such: > > --- upslog.c.orig 2012-07-31 10:38:58.000000000 -0700 > +++ upslog.c 2014-02-20 09:23:14.000000000 -0800 > @@ -50,6 +50,7
2014 Nov 07
5
RFC: new variable battery.status
On 11/3/2014 9:25 PM, thomas schorpp wrote: > Hi Ted, > > Am 04.11.2014 um 04:12 schrieb Ted Mittelstaedt: >> > >> Note that since the UPS relies on the voltage from the battery pack to >> determine state of charge, it is quite useful to add in the battery pack >> voltage to the logs as such: >> >> --- upslog.c.orig 2012-07-31 10:38:58.000000000
2014 Feb 20
1
Logic problem in NUT with upscode2 driver
On 2/20/2014 6:55 AM, Charles Lepple wrote: > On Feb 19, 2014, at 12:50 PM, Ted Mittelstaedt wrote: > >> Worse, however, is if there's a power failure right near the end of >> the 2-days-off cycle. That happened to me last week - it was a >> short duration 15 second loss - and the upscode2 driver decided it >> needed to issue a forced shutdown. >> >>
2014 Nov 08
0
RFC: new variable battery.status
Dear Ted, Am 07.11.2014 um 17:47 schrieb Ted Mittelstaedt: > On 11/3/2014 9:25 PM, thomas schorpp wrote: >> Hi Ted, >> >> Am 04.11.2014 um 04:12 schrieb Ted Mittelstaedt: >>> >> >>> Note that since the UPS relies on the voltage from the battery pack to >>> determine state of charge, it is quite useful to add in the battery pack >>>
2005 Dec 29
1
Deltec PRA1500 UPS and FC4
I recently bought new batteries for this old "Compaq" Deltec PRA 1500 ups and downloaded LanSafe3 and haven't had much luck communicating with the UPS via a serial cable. Does anyone out there have a manual on this UPS? Or has anyone else gotten this to work with LanSafe3 and/or upsd? Any help would be greatly appreciated! Jon Moss __________________________________
2010 Mar 03
1
using upscode2 driver with Powerware 5119 RM
I've got a Powerware 5119 RM UPS. driver.list says to use "genericups upstype=20", however I know this UPS supports the UPS Code II protocol, so I wanted to use the upscode2 driver. It took some hacking but finally it works. I'm using NUT 2.4.1 and upscode2 driver version 0.87 (however the latest r2350 version of upscode2.c isn't significantly different, so I think all
2017 Jul 22
3
Compaq R3000h support
Hi List. I have an old Compaq 3000 (Eaton 5119). It is running servers, disk-arrays, one workstation etc. I am planning to install NUT (master) on a headless CENTOS 6.8 system. Connect the UPS with seral cable. Now my main question is, Does NUT support the power segments on the UPS. My intention is to be able to take down the system in an ordered way before the batteries are exhausted. I.e 5 mins
2017 Jul 22
2
Compaq R3000h support
On Sat, Jul 22, 2017 at 7:48 AM, Charles Lepple <clepple at gmail.com> wrote: > > I also have not used a Synology device, but as I recall, they generally > expect to be the NUT master system. This may cause problems if you need to > do something fancy with upssched. > The Synology boxes work fine as NUT clients, *however* they provide very little ability to configure NUT
2014 Nov 08
1
RFC: new variable battery.status
On 11/8/2014 6:54 AM, thomas schorpp wrote: > Dear Ted, > > Am 07.11.2014 um 17:47 schrieb Ted Mittelstaedt: >> On 11/3/2014 9:25 PM, thomas schorpp wrote: >>> Hi Ted, >>> >>> Am 04.11.2014 um 04:12 schrieb Ted Mittelstaedt: >>>> >>> >>>> Note that since the UPS relies on the voltage from the battery pack to