2010 Nov 05
1
APC CS650/550 not turning load back on when power return
Hi all, I have a APC Back-up CS500 and have the same problem as posted in the http://lists.alioth.debian.org/pipermail/nut-upsuser/2010-October/006243.html thread. Does somebody figure out the command, which was send to the UPS to shutdown the UPS after a delay time with a automatically with switch on after power return. Best regards R.
2008 Dec 01
1
APC Back-UPS CS 500 power cycle
Hello, we have a problem using APC Back-UPS CS 500 (connected via USB, usbhid-ups-apc) and UPS-NUT. We've tried different Versions of UPS-NUT (2.2.1 and 2.2.2), including the latest from SVN (28th November 2008). We've also tried apcupsd, which works fine for our requirements, but we don't want use it. What we need is simple: The UPS should turn off after power loss and shutdown
2015 Jan 09
0
NUT configuration with APC CS650 and ESXi host
On Jan 7, 2015, at 6:11 PM, DatGingerCat <dat.ginger.cat at gmail.com> wrote: > Hello, > > I have decided to upgrade my home server by turning it into an ESXi host and have also added an APC CS650 UPS. > My plan was to have NUT version 2.6.4 running in a Debian 7.7.0 virtual machine, NUT installed using apt. > I configured NUT to run as a netserver, installed the ESXi nut
2015 Jan 11
1
NUT configuration with APC CS650 and ESXi host
The serial number looks completely different, but the firmware seems to be the same. Pasting upsc output: battery.charge: 80 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2013/12/04 battery.mfr.date: 2013/12/04 battery.runtime: 1781 battery.runtime.low: 120 battery.temperature: 29.2 battery.type: PbAc battery.voltage: 13.5 battery.voltage.nominal: 12.0 device.mfr: American Power
2015 Jan 07
2
NUT configuration with APC CS650 and ESXi host
Hello, I have decided to upgrade my home server by turning it into an ESXi host and have also added an APC CS650 UPS. My plan was to have NUT version 2.6.4 running in a Debian 7.7.0 virtual machine, NUT installed using apt. I configured NUT to run as a netserver, installed the ESXi nut .vib, configured the shutdowncmd in the VM to do nothing, so that the ESXi host would close that virtual machine
2009 May 08
1
Battery test feature of APC Back-UPS RS series
Hi all, I use an APC Back-UPS RS 800, overall my experience with NUT is very good but there is one feature I am missing: the ability to ask the UPS for a battery test. upscmd -l shows the following commands available: $ upscmd -l rs800 Instant commands supported on UPS [rs800]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS
2010 Jun 25
3
Using snmp for APC smarts
Hi, I'm new to nut. I have some 100 APC Smart-UPS 2200 & 3000's and I'm trying to do some calibration test on them. I've installed nut, with driver = snmp-ups mibs = apcc in ups.conf. I can read the variables using upsc. However it seems, I can't actually execute commands on the UPSses this way. ( upscmd some-ups calibrate.start ) Do I miss something, or are those
2017 May 11
4
APC Back-UPS XS 1500G says "No battery"
I have a new-ish APC Back-UPS XS 1500G connected via USB. It's giving me a "ups.alarm: No battery installed!" error. I also installed and configured apcupsd to give that a try and it's giving me the same error. I suspect this is a driver problem because while NUT claims the battery isn't plugged in, it's giving me battery runtime/charge info. Both can't be valid
2013 Sep 21
2
Smart-UPS staying in OB after power return
Hi list, UPS is a Smart-UPS 3000 RM (SU3000RM3U, ups.firmware 92.11.D, ups.mfr.date 12/14/99) with brand-new batteries. NUT is 2.6.5 running on SL6 (RHEL6 clone) from EPEL packages. 'upsc' output pasted at bottom. I'm not very familiar with UPSs in general or this model in particular, and it's doing things I don't expect. I have done my homework, and read UPS user manual,
2010 Nov 07
3
Support of "shutdown.return" on a APC Back-UPS CS 500
Hi all, I am trying to get a APC Back-UPS CS 500 running on my QNAP 419P Nas. Since on all my work I figure out the following: from Network UPS Tools upscmd 2.4.1 [~] # upscmd -l qnapups Instant commands supported on UPS [qnapups]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use
2013 Sep 21
0
Smart-UPS staying in OB after power return
John Morris wrote, On 9/21/2013 11:28 AM: > Hi list, > > UPS is a Smart-UPS 3000 RM (SU3000RM3U, ups.firmware 92.11.D, > ups.mfr.date 12/14/99) with brand-new batteries. NUT is 2.6.5 running > on SL6 (RHEL6 clone) from EPEL packages. 'upsc' output pasted at bottom. > > I'm not very familiar with UPSs in general or this model in particular, > and it's doing
2007 Sep 16
1
Can't get 'load.off' to turn off power to the PC: CyberPower 1200AVR
I'm running Network UPS Tools 2.2.0 on a Linux machine, running CentOS 4.5 (RedHat Enterprise Linux 4.5), with a kernel version 2.6.9. I believe I have the software setup and configured properly. I can access the UPS via the upsc (client) tool, upscmd, upsmon, etc. Even the CGI pages provide me with the ups status, etc. However, when I try to shut off the load using the load.off instant
2014 Dec 17
2
interrupt pipe disabled [APC SMT3000RMI2U]
On Dec 17, 2014, at 3:46 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote: > This seems to me a little bit complicated :-( Instead, can I use the > apcsmart driver with the provided 940-0625a c?ble (RJ45/DB9 connectors) ? Or > do I need to acquire an AP9620 SmartSlot expansion card, as I've seen in the > Hardware compatibility list page ? It sounds like you might
2010 Jul 20
2
APC 5G UPS APC-HID
I've grabbed a snapshot of NUT from just a couple days ago. Glad to see APC's new 5G UPSes added to the list (though you probably want to add it to the UDEV 52-nut-usbups.rules file as well...). My issues with new APC Smart-UPS units (SMT1000) : Powering-down the unit, whether with upsdrvctl or upscmd will not obey the specified delay in offdelay, or ups.delay.shutdown. Instead, a
2018 Dec 26
0
APC Back UPS and Best Power FERRUPS?
On Dec 25, 2018, at 4:07 AM, David Melik wrote: > > Lately I got (used) an APC Back UPS Pro 1000 and Back UPS NS 1080. I got an [8P8C]-to-USB cable from another UPS, but the Pro isn't detected (with usbhid-ups.) I haven't tried the NS yet but it seems to not be on the list though looks just like the Pro. > There are a few different angles we can approach this one from. What
2014 Dec 18
0
interrupt pipe disabled [APC SMT3000RMI2U]
> Also, I don't think we have any confirmation of the variables that the AP9620 provides. Here is the list of full 'upsc' output for various APC models: > > http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/APC/index.html Frantz, Actually, it would be useful if you could send a copy of the output of 'upsc', 'upscmd -l' and
2020 Feb 20
3
Problem with APC SMC1500I-2UC & Synology DS1819+
I'm having an issue with my ups that is connected too my NAS via usb its reporting the battery as 99% OL CHARG when the ups is at full charge 100% ONLINE does anyone have any tips its driving me crazy Sent from my Samsung Galaxy smartphone. -------------- next part -------------- An HTML attachment was scrubbed... URL:
2018 Dec 25
3
APC Back UPS and Best Power FERRUPS?
Lately I got (used) an APC Back UPS Pro 1000 and Back UPS NS 1080. I got an ethernet-to-USB cable from another UPS, but the Pro isn't detected (with usbhid-ups.) I haven't tried the NS yet but it seems to not be on the list though looks just like the Pro. Some months ago I was discussing setup of a Ferrups 700VA.  I got it to work only with a command in rc.local, but not automatically
2014 Nov 09
0
APC Smart-UPS C1500 connected by usb
On Nov 8, 2014, at 6:12 PM, Selva Nair <selva.nair at gmail.com> wrote: > Everything works rather well, except that the cgi-interface does not report input/output voltages and load for the C 1500 unit. > upsc also reports these values only for model 1000, not for 1500. Battery charge is and runtime are reported. For the 1000, do the values match this page?
2014 Nov 08
3
APC Smart-UPS C1500 connected by usb
Hi, I have setup NUT in netserver mode on debian wheezy with two APC UPS units connected to it by usb. lsusb identifies the units as Smart-UPS 1000 and Smart-UPS C1500. It appears these do not use the smart protocol and usbhid-ups is the correct driver to use. System: Debian wheezy with stock version of nut (Version: 2.6.4-2.3+deb7u1) Everything works rather well, except that the