similar to: Powercom BNT-800AP

Displaying 20 results from an estimated 200 matches similar to: "Powercom BNT-800AP"

2011 Oct 04
2
PowerCOM BNT-800AP (0d9f:0004)
Hello. I've been trying to got it work but haven't luck. I'm using NUT 2.6.0-1 under Windows XP with libusb driver installed (USB\VID_0D9F&PID_0004&REV_0001). I had tryed all options with such config: *PWCOM] driver = usbhid-ups port = auto vendorid = 0d9f desc = "Powercom BNT-800AP" type=BNT* * *Here is output from CMD:*
2011 Jan 13
0
[NUT]updated powercom driver for powercom BNT-500AP
Hi, 2010/12/27 ??? <pointbre at naver.com> > First of all, thanks for your effort to NUT Project, > I'm developing remote monitoring solution for many devices based on linux > server. > In field test, we reached the power shutdown problem which may cause the > crack of linux file system. > I search the solution and find NUT project and i'm very glad that NUT >
2013 Jun 05
2
several problems with Powercom BNT-500AP
OS name and version: pi at raspberrypi ~ $ cat /etc/*release PRETTY_NAME="Debian GNU/Linux 7.0 (wheezy)" uname -a Linux raspberrypi 3.6.11+ #393 PREEMPT Fri Mar 8 16:36:28 GMT 2013 armv6l GNU/Linux exact NUT version pi at raspberrypi ~ $ dpkg -s nut Package: nut ... Version: 2.6.4-2.3 NUT installation method: package exact device name and related information:
2013 Nov 27
0
several problems with Powercom BNT-500AP
Hello. It's been a while since I started this topic. I've finally tested it on Linux desktop PC. Nut version 2.6.4-2.3 Basically the behavior is the same as on raspberry pi. It reports "battery needs to be replaced" regularly and I got "on battery" message 114107.780504 Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x0a, Offset: 2, Size: 1,
2013 Jun 08
2
several problems with Powercom BNT-500AP
Thanks for the support. Here's list of when transition to battery with return to utility power within a few seconds occurred in last few days: Wednesday 1:41 11:48 11:54 12:59 13:42 14:42 18:13 18:14 Thursday 5:23 Friday 5:12 7:39 7:43 Saturday 7:34 Here's list of when messages that battery needs replacement occurred: Wednesday 20:34 Thursday 9:07 23:09 Friday 18:25 Saturday 7:32 19:47
2013 Jun 10
2
several problems with Powercom BNT-500AP
I took the log. Here's what happened. Broadcast Message from nut at rasp (somewhere) at 16:18 ... UPS BNT500AP at localhost battery needs to be replaced occurred when for the first time value "1" was read as "UPS.PowerSummary.PresentStatus.NeedReplacement", on this line: 6409.240690 Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Input, ReportID: 0x0a,
2013 Jun 08
0
several problems with Powercom BNT-500AP
On Jun 5, 2013, at 11:49 AM, M?rti?? Pu??tis wrote: > Driver debug output attached. The debug output looks normal (many devices do not implement the interrupt pipe; hence, the timeouts). Unfortunately, we might need the log over a longer period of time, including your observations as to when various events occurred (such as transitions to battery). -- Charles Lepple clepple at gmail
2013 Jun 08
0
several problems with Powercom BNT-500AP
On Jun 8, 2013, at 12:57 PM, M?rti?? Pu??tis wrote: > I'll take a longer driver log. This page (http://www.networkupstools.org/support.html) says that to take a driver log NUT should be stopped, so I won't be able to tell when these events occurred within a driver log. Hmm, I didn't realize it said that, but I think that's to prevent having two copies of the same driver
2013 Jun 11
0
several problems with Powercom BNT-500AP
[I am CC'ing Alexey from Powercom in case he has seen any of these issues with the Raspberry Pi hardware.] On Jun 10, 2013, at 1:05 PM, M?rti?? Pu??tis wrote: > I took the log. Here's what happened. > Broadcast Message from nut at rasp > (somewhere) at 16:18 ... > UPS BNT500AP at localhost battery needs to be replaced > > occurred when for the first time value
2006 Dec 11
2
howto setup BNT-1500AP on gentoo
Good afternoon. I try to put nut on gentoo. Has executed installation by a standard command emerge nut. All has passed successfully. I use UPS POWERCOM BNT-1500AP. It is connected to serial port 1, i.e. for my system it/dev/tts/0. In/etc/nut/ups.conf [powercom] driver = powercom port = /dev/tts/0 desc = "PowerCom BNT-1500AP on IP-PBX" modelname = "BNT-1500AP" linevoltage = 230
2007 Nov 06
1
BNT-1000AP
Hi guys, We've got a BNT-1000AP (powercom) BlackKnight UPS that works with the KIN1500AP model in the powercom driver. Well, almost. It seems the input frequency and the battery charge is swapped around: # upsc blackknight at localhost battery.charge: 46.5 driver.name: powercom driver.parameter.manufacturer: BlackKnight driver.parameter.modelname: BNT-1000AP driver.parameter.port:
2005 Jul 06
0
Powercom BNT-1500AP
Hey all, Does anybody know there is a full working setup for the PowerCom BNT-1500AP. I got some stuff working with the Powercom driver and the type set to "KIN1500AP". But it seems that there is still missing usablity. I was wondering if anybody found any better configs? ---- excerpt of ups.conf [AVR1500] driver = powercom port = /dev/ttyS0 desc =
2006 Apr 21
1
Powercom BNT-1200AP
Hello I have UPS Powercom Black Knight Pro 1200 (BNT-1200AP) I try to use nut, but powercom driver not understand my model Ok, i try to use type KIN1500AP and it's work But powercom driver can't set UPS's shutdown delay time Also i have powercom's original program (upsmon), and this program can do it What can i do for help to add this function to nut's powercom driver? For
2006 Jul 08
0
Powercom BNT-600AP and NUT (powercom driver)
Hello, I'm new there. I bought an UPS Powercom BNT-600AP. It's compatible in NUT with driver powercom and protocol type KIN1500AP. But I have a simple problem: the 'upsc' shows wrong values in battery.charge (maybe in other rows also /ups.load, voltages?/) - if battery is 100% charged it shows only 92.6% or 93.0%. I thing I have wrong values in driver parameters: batteryPercentage,
2012 Nov 13
1
PowerCom BNT-600AP on ubuntu 12.04.1 AMD64
Hello people, I use a BNT-600AP from PowerCom, and on driver loading (nut service start) the UPS goes off so I cannot use nut as service as the computer goes off with the UPS. When the computer is not using the UPS, but still connected, I see that the UPS goes off for a very short time, does battery check and goes on again. I don't know how to deal with this issue as I cannot use my UPS
2009 Jul 27
1
Powercom BNT-1000CS
Hello. I have recently purchased a Powercom BNT-1000CS(Black Knight CS). I am new to NUT(and am not a programmer), but I have noticed that this model does not work with NUT. I am willing to provide details about this UPS for anyone who would like to add support for it(i dont know how to get much info though, so you'll have to tell me how). For starters, this is what happens when I do
2017 Apr 26
0
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent three last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2013 Apr 28
0
PowerCOM BNT-1000AP HID instant commands patch
Hello, Got PowerCOM BNT-1000AP, usb id 0d9f:00a6, firmware FW4.A6 nut 2.4.3 on debian stable shows only two instant commands: beeper.toggle - Toggle the UPS beeper -- not working test.battery.start.quick - Start a quick battery test -- works ok. No load and shutdown commands. Trying svn trunk version, with the same results. Debug output shows the problem: 0.035558
2005 Aug 06
0
Driver for Ultra UPS BNT-1000AP
Hi I purchased an Ultra 1000VA UPS (http://www.ultraproducts.com/product_details.php?cPath=35&pPath=154&productID=154) I am trying to use nut with it (I am using gentoo linux) but can't find the proper driver. The numbers on the back suggest it might be similar to Black Knight Pro BNT-1000AP from Powercom (http://www.powercom-usa.com/ProductDetail.asp?ID=8974). So I tried the powercom
2017 Apr 30
0
Powercom BNT-2000AP(USB)
On April 28, 2017 9:11:59 AM GMT+03:00, "????????? ?????????" <vtk-alexb at mail.ru> wrote: >Hello all! > >Some days ago we received new UPS?Powercom BNT-2000AP with USB >interface to replace an old staff and I've spent four last days trying >to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. > ># dmesg|grep -i powercom >ugen0.3: