similar to: SmartUPS-600 problem with 940-0024C cable

Displaying 20 results from an estimated 2000 matches similar to: "SmartUPS-600 problem with 940-0024C cable"

2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all, Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h. Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS 1250 as a "dumb" UPS.) For NUT 2.0.5+. NUT 2.0.5: Patches apply successfully. Builds successfully. Works as expected under Ubuntu 7.04. NUT 2.2:
2005 Aug 08
1
Here are CORRECT APC cable diagrams
+-----------------------------------------------------------------+ | | | Black APC 940-0024C Smart Signalling UPS Cable Wiring Diagram | | This information is verified and tested to be 100% correct. | | |
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the manufacturer's PowerChute software and smart signaling, so I have decided to try NUT. The smartups driver can't make contact through the serial port. Since this is rack-mounted, it comes with a 940-1524 serial cable. As far as I can tell, this is supposed to work with smart signaling. Here's my ups.conf:
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set
2009 Jul 06
3
Smart-UPS RT 3000 Baud Rate
I have been running a Smart-UPS RT 3000 VA using nut successfully over the 940-0095B cable for a couple of years. I have just received a second unit, but it is slightly different in 3 ways that I have found so far. 1. It's a Smart-UPS RT 3000 XL 2. The 940-0095B cable now uses an RJ45 connector at the UPS end. 3. It now requires a baud rate of 9600 instead of the 2400 used previously.
2007 Jan 30
5
initial configuration assistance
Hi, I've browsed the archives back for a few months and nothing has jumped out at me as being helpful, but since there doesn't seem to be a search facility it's certainly possible I've missed what I'm looking for. Anyway, I wonder if someone can help me. I've very recently installed nut 2.0.4-r1 on a gentoo box and am in the initial stages of configuration and testing.
2009 Aug 14
1
Have an older Back-UPS Pro 1400(BP1400) can't get detailed info.
I just installed nut, and I it is detected but I don't get any usefull information. I have the serial cable that came with it which is a 940-0024C and I tried setting that in the driver, but no difference. What can I do to get stuff like battery voltage and such? Thanks, Brian upsc ups1 at localhost driver.name: apcsmart driver.parameter.cable: 940-0024C driver.parameter.pollinterval: 2
2006 Mar 02
1
Problem after reboot
Hello all, Rebooted my server by mistake (don't ask...) - everything was working OK before the reboot, but after the reboot, NUT stopped working - so had a look and I found I couldn't track the exact problem - I'm quite stumped as there's nothing indicating that there's a problem, but it just doesn't work... In a nutshell.... destiny:/usr/local/ups/bin# ./upsdrvctl
2006 Mar 02
1
Problem after reboot
Hello all, Rebooted my server by mistake (don't ask...) - everything was working OK before the reboot, but after the reboot, NUT stopped working - so had a look and I found I couldn't track the exact problem - I'm quite stumped as there's nothing indicating that there's a problem, but it just doesn't work... In a nutshell.... destiny:/usr/local/ups/bin# ./upsdrvctl
2014 Jul 09
2
APC SmartUPS switches off with no reason
Hello One our customer has two Linux HP-branded servers powered from "clasic" APC Smart-UPS 2200 RM 2U (p/n SUA2200RMI2U). It is connected to first server via RS232c port with APC-branded cable. We have installed NUT 2.6.4 with apcsmart driver. This setup works fine for months. Two weeks ago all the hardware powered from the UPS started to switch off occasionally while on line
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. >
2008 Sep 19
1
APC SmartUPS 750 (SUA750) missing ambient data with usbhid-ups
I have a SmartUPS 750 (SUA750) which has the temperature and humidity SmartSlot card installed. When NUT 2.2 communicates with this UPS over /dev/ttyS0 using apcsmart, using the APC Smart cable connected to the SUA750 serial port, and this ups.conf: [su700] driver=apcsmart port = /dev/ttyS0 I can see the ambient temperature and humidity data with "upsc su700 at
2007 Jan 21
1
APC Smartups protocol - Hidden Programming Mode
Hej! Hope nut-upsuser is an appropriate place to post additional info about the smartups protocol, please tell me if not. I got an APC Smartups 2200 (5U Rack Mount, European/230V version, 48V batteries) a couple of days ago, was very happy to find the protocol description at http://www.networkupstools.org/protocols/apcsmart.html, and started to play. At the point when everything was working
2009 May 25
1
APC Smart UPS 900i
Hi, I'm running an old APC Smart UPS 900i. As there isn't any software from APC which supports this UPS anymore, I've installed NUT (Gentoo Ebuilds), but version 2.0.5 and version 2.2.2 loose connection to the UPS while version 2.4.1 and SVN version don't show any settings and there are no instant commands. The only information I can get are: driver.name: apcsmart
2006 Aug 13
2
can't get UPSDRV to see serial port
First, a little history; nut has been working on this system for about two years. It was a Fedora Core 2 (3?) system that I wiped and installed SUSE 10.1 on so I'm fairly confident of the hardware. I thought I'd saved the nut configuration details before I did the reinstall, but can't find them. (D'oh!) The UPS is an APC BackUPS Pro 420. The cable is a clone of the APC
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2012 Nov 18
2
Control power output via serial connection
Hi, I have two APC UPS models and I am trying to find out if it is possible to cut power down via serial connection in Ubuntu Server 12.04.1 AMD64 system. I have models: APC Back-UPS Pro 650 (BP650SI) APC Back-UPS 650 (BK650MI) I have also APC serial cables 940-0020C and 940-0095B. Is this possible with my current hardware? If it isn't possible, could you recommend model(s) on
2007 Dec 12
1
[PATCH]Support full capabilities on older Smart-UPS 600
Hi, The patch below adds support for a pair of old (circa 1993) APC Smart-UPS 600 devices that I have. They don't support the query mechanism of newer APC devices but do respond to the full Smart-UPS command set: battery.alarm.threshold: 0 battery.charge: 100.0 battery.charge.restart: 00 battery.date: 02/22/93 battery.runtime: 2040 battery.runtime.low: 120 battery.voltage: 27.67
2007 Jan 12
1
Trouble connecting to apc smart 1500 via serial cable
Hello. I've been running a two machine setup with a mge-shut for some time without problems, and now I'm configuring a three machine setup with an APC Smart 1500. The UPS has three machines connected to it, in a peculiar way: one windows machine is connected via USB. The second windows machine is using an agent to monitor messages from the first windows machine. Then, I have a GNU/Linux
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi Arnaud, > Hi Thomas, > I just checked the 2.4.1 version of nut and found that you forgot to add > my old UPS model (APC Smart-UPS 900). I guess it is because you were > busy at the time when I sent you the patch. So here it goes again. :) > uh, right sorry. I was pretty sure I applied