similar to: TE410 and 411

Displaying 20 results from an estimated 3000 matches similar to: "TE410 and 411"

2006 Apr 27
12
PRIs from two different telco
My TE411p does not seem to like to have two PRIs from different telcos (span 1 and span 2). I can get one working, but not the other. However, if I use vpmsupport=0 when loading the wct4xxp module, they both work. But here is the problem, vpmsupport=0 disables the on board echo cancellation. Any ideas? BTW, here is zaptel.conf span=1,1,0,esf,b8zs span=2,2,0,esf,b8zs bchan=1-23 dchan=24
2007 Sep 18
1
Dell Power Edge 1900
Does anyone know if the Dell Power Edge 1900 has an issue with multiport E1 cards? We've had this server running for a while now with 2 E1 cards. At first we tried to install an Openvox D210P card with two E1 ports but after a couple of kernel panics we thought that maybe the card was defective and we replaced it with two Digium TE120P cards. Now the customer needs a third E1 port and
2007 Oct 17
3
Asterisk using 200% CPU and then crashing...
We have a customer that has Asterisk 1.4.12.1, Zaptel 1.4.5.1, Asterisk-Addons 1.4.3. running on a Dell Poweredge 1900 server (Dual Core Xeon, 4gb RAM, 500gb Raid 5). Until a month ago they had two TE120P cards and everything was working fine. Since they needed to add a third E1 line we decided to change one of the TE120P cards with a TE210P. After the change we had a couple of crashes (server
2006 Feb 01
2
DTMF Sporadicaly Being Generated
I just wanted to see if any one else has seen this or could help point me in the right direction on this problem. I have a TE411P card in my * box. I am running FC4 x86_64. I used to have two TE110 cards in the same box that worked without any problems. Since changing to the TE411P cards, I am getting random DTMF tones being produced on a bridged connection through the same Channel Bank that I
2006 May 16
6
DELL PowerEdge 2850 and TE4110P and TE110P
Hi All Before I go out and buy a DELL PowerEdge 2850 has anyone had problems (or any other useful experience) getting a TE411P to work with it. I also have a legacy TE110P. Has anyone had problems with this combo. -- Dr. Rodney G. McDuff |Ex ignorantia ad sapientiam Manager, Strategic Technologies Group| Ex luce ad tenebras Information Technology Services | The
2005 Oct 12
3
E400P vs te410p vs te411p
Hi, I found E400P quad PRI card quite cheap (749USD): http://www.govarion.com/product_info.php?cPath=1&products_id=2&osCsid=68cdd6e3d08754 in comparison to te410p (approx 1500 USD ) http://www.digium.com/index.php?menu=product_detail&category=hardware&product=TE410P Now newer generation with HW echo canceling emerged (te411p). I'm not sure in what things those two cards
2009 Dec 03
2
Help R2WinBUGS
Hello, I have problem running WinBUGS from R. The following example works in WinBUGS but it does not work in R through package R2WinBUGS. Does anyone know what the problem is? x <- c(0.2, 1.1, 1, 2.2, 2.5, 2.9, 2.9, 3.6, 3.8, 0.6, 1, 2, 2.4, 2.6, 2.8, 3.2, 3.9, 3.5) y <- c(0.5, 1.3, 0.1, 0.7, -0.4, 0.5, -0.9, -0.3, -0.3, 0.6, 0.4, 0.9, -0.1, -0.4, -0.5, -0.2, 0.3, -1.5) eco <- c(1, 3,
2006 Apr 27
5
PRI configuration
Hi, I am getting this message on the * console on my first pri span. Pri show span show it is down, and I can't make any calls from the span. Apr 27 07:40:23 NOTICE[23988]: chan_zap.c:8202 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Apr 27 07:40:23 NOTICE[23988]: chan_zap.c:8202 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Apr 27
2012 May 07
1
Sprockets, JST, Eco and escaping
While it was a good move from Rails part to escape ERB <%= %> tags by default, it doesn''t seem to happen to Sprockets as well. The strange bit is that according to Sprockets documentation, it would be just a matter of naming your template as .jst.eco to enable Eco: https://github.com/sstephenson/sprockets#javascript-templating-with-ejs-and-eco Then, extracted from Eco
2010 Jun 09
1
equivalent of stata command in R‏
From: saint-filth@hotmail.com To: saint-filth@hotmail.com Subject: RE: Date: Wed, 9 Jun 2010 09:53:20 +0000 OK! sorry thats my fault, here the translations of the stata commands 1st step is to get the mean values of the variables, well that doesnt need explanation i guess, 2nd step is to estimate the model on panel data estimation method which is:
2007 Jul 18
1
creating a world map of eco-climatic zones
Hello R users: I would like to produce a world map with countries colored according to whether they fall into one of 7 eco-climatic zones. For simplicity, each country is allocated to exactly 1 eco-climatic zone. For this purpose I have looked at the map and mapdata packages, which contain world maps composed of polygons (1 for each country, it seems). Each of the polygons can be referred to by a
2007 Mar 14
2
ols Error : missing value where TRUE/FALSE needed
I have installed Hmisc and Design. When I use ols, I get the following error message: Error in if (!length(fname) || !any(fname == zname)) { : missing value where TRUE/FALSE needed The model that I am running is: > ecools <- ols(eco$exp ~ eco$age + eco$own + eco$inc + inc2, x=TRUE) I have tried several other combinations of arguments that take TRUE/ FALSE values, but no luck.
2006 Feb 01
2
TE411P or TE406P
Hi Guys, I need your recommendation which card to buy?The TE411P or TE406P do they have any difference?I check their brochures they are differ only when it comes to PCI slot voltages.Which card best to use?Btw,Il be using supermicro board with 3.3V and 5.5V?Will il be experiencing problem during the implementation later on if i choose the wrong PCI voltage options?Will it depends on
2019 Apr 11
1
ondelay parameter does not work with NUT on Raspbian and Eaton 5E850iUSBDIN UPS
On Wed, 10 Apr 2019, Bartosz wrote: > BTW,does it have passive cooling? In the sense that there is no fan, The Eaton Ellipse ECO 1600 has passive cooling. It gets warm but not hot. > Are you happy with your Eaton Elipse ECO 1600? Does it work well with ondelay? "ECO" means that it does not have "buck and boost" or a fancy control panel. I replace my batteries
2010 Jun 09
1
equivalent of stata command in R
Dear all, I need to use R for one estimation, and i have readily available stata command, but i need also the R version of the same command. the estimation in stata is as following: 1. Compute mean values of relevant variables . sum inno lnE lnM Variable | Obs Mean Std. Dev. Min Max -------------+--------------------------------------------------------
2005 Sep 08
2
TE411P zapata.conf, monitoring echo cancellation and echo tail size
Hi all, 1. Just bought a new TE411P and about to install it replacing the existing TE410P. I am assuming I need to set echocancel=no and echocancelwhenbridged=no now that it will be done in hardware, correct? 2. Is there any way to monitor hardware echo cancellation to ensure it is working (apart from being on a call)? 3. The Digium webite says "By supporting 16ms with 128 channels or
2006 May 31
1
Brief silence followed by DTMF tone on T1 line
Every once in a while calls get interrupted with a brief silence followed by a DTMF tone on our T1 lines. We are using a TE411P card. It does not happen on SIP connections, just the T1. Has anyone experienced this or know a possible cause? Thanks, -Bill
2007 Feb 07
2
CPU & motherboard for 100+ simultaneouse calls on Digium Quad E1 TE411p
hi! anyone please recommend/guide me of purchasing a resonably high performance server system regarding processor(s) & motherboard (+ other compulsary peripherals i.e. VGA, Soundcard). Mentioning up-to-date vendor+model will be more helping I've to use Digium TE411p Quad E1 card signalling on the E1 is SS7 no. of simultaneouse calls is 100+ regards -------------- next part
2014 Oct 02
2
Socomec ITYS 3000 + Netvision upsmon output
On 02.10.2014 03:42, Charles Lepple wrote: > On Oct 1, 2014, at 5:07 AM, Tarvo.Tiits at automaatika.ee wrote: > >> Why is ups.status empty? > If I understand the commit log for SVN r3590, then that revision was supposed to set the status to OL if the numeric state was 9 for ECO mode. It does not appear to do that: > >
2006 Mar 01
1
TE411P VPM
Does anyone know how to disable the VPM in software rather than removing the card altogether? The canceler isn't working as well as the software cancelers were. Aaron