2005 Oct 10
2
Asterisk and Mitel SX 200 Slip and Frame Errors causing Major Ala rms
We have integrated an Asterisk (TE110P) and a Mitel SX200. We usually get over 500 frame errors and over a 500 slip errors per hour. When the errors reach 1000 per hour the Mitel will take it's T1 card offline. At that point no calls can be routed from the Asterisk server to the Mitel and the TE110P reports a Yellow alarm. What can be causing all these Frame and Slip errors? We have been
2005 Apr 22
4
TE11OP -> Mitel 200Sx??
Hello all. I just received a TE110P and am trying to hook it to my Mitel 200SX has anyone successfully done this? My configuration is as follows. Asterisk -> TE110P ->Kentrox (csu/dsu) -> Mitel T1 Card. All I get is a blinking yellow on my TE110P card and an alarm on my Mitel. T1 card. Any advice would be great. Zaptel.conf span=1,0,1,d4,ami e&m=1-23 dchan=24
2005 Oct 06
1
Results of an incorrect crossover pinout??
Say I had a crossover cable that connected a Mitel SX200 to a TE110P and the pinout was done as such: 1 - 4 2 - 5 5 - 1 4 - 2 (the 5 and 4 are transposed on the left side) Instead of the proper way of: 1 - 4 2 - 5 4 - 1 5 - 2 What would the results be? We have had the former as our cabling for a few months and the connection has been fine. Slip errors here and there. But we have had major
2005 Jul 22
1
Interconnect with Mitel PBX
I have a small government department that wants me to implement a Asterisk installation, however, they connect to the Government PBX, a Mitel SX200, and want to keep the ability to do that. I know there is no chance to connect the digital extension lines, but would it be possible to have the pbx admins send analogue extensions over and have those lines interface through an FXO interface? Or
2007 Feb 26
3
Yellow or Red alarm on TE110P ????
i get this message with a red signal on TE110P card: ***************** TE110P: span configured for... Calling startuo (flug is 4099) wcte1xxp: Setting yellow alarm ***************** what does mean ? thank you :)
2005 Oct 12
0
Zaptel Debug: "T1: Lost our place, resyncing "
We are trying to debug a connection between Asterisk and a legacy PBX (Mitel SX200). We turned on the Zaptel debugging and we get the following message quite frequently: Oct 12 07:14:09 localhost kernel: T1: Lost our place, resyncing ( 28 ) Oct 12 07:14:09 localhost last message repeated 3 times -- Oct 12 07:14:11 localhost kernel: T1: Lost our place, resyncing ( 28 ) Oct 12 07:14:11 localhost
2006 Mar 15
2
Script to Restart Zaptel
We are runnign into problems where our legacy PBX reaches a frame loss threshold and takes it's T1 card offline (the T1 card that interfaces with the Asterisk servers TE110P). During this time, the Asterisk server senses a Yellow alarm. We've noticed that if we quit asterisk, stop zaptel, start zaptel, start asterisk that the alarm condition clears on the legacy PBX. We'd like to be
2007 Sep 12
1
TE405P intermittent yellow alarm
Folks, I really hope you can help me here - I'm beginning to tear my hair out! About 10 days ago my company moved to a new office. As a result of this, we've plugged our PBX box, which has happily been running for the last three years, into our new E1 line. Since then, I've been seeing intermittent yellow alarms. Obviously, since this was working fine in the old office, the thing to
2005 Aug 24
1
Yellow Alarm issues with second TE410P installed
Hi, Ok, I put the new TE410 into our system last night - This is the second TE410P card. There is also TDM400P in Slot 5 with IRQ 9 which is shared with aic7xxx (SCSI) According to "cat /proc/interrupts", the new card is in the second slot using IRQ 11 (the first card is in slot 1 on IRQ 10 - but always has been). With only the original card install, there has been no issues with
2011 Feb 21
1
T1 PRI shows yellow/red alarm
We are running Asterisk version 1.4.23-1, libpri-1.4.9 and zaptel-1.4.12.1 and two Digium TE220Ps. Debugs are set to 10. We have a T1 PRI connected to the telco. Over the last 4-5 days, we have getting Yellow/Red alarms coming from the T1 PRI. The other two ports in use are connected to internal test switches (Avaya Legend/Avaya Definity), and are not showing any errors.
2005 Feb 18
6
W&M Wink timings for Nortel
Does anyone know the default E&M Wink timings for Nortel DID ports? The default settings on Asterisk are: ; prewink: Pre-wink time (default 50ms) ; preflash: Pre-flash time (default 50ms) ; wink: Wink time (default 150ms) ; flash: Flash time (default 750ms) ; start: Start time (default 1500ms) ; rxwink: Receiver wink time (default 300ms) ;
2003 Mar 13
1
E1 yellow alarms
About every hour I see the yellow alarms on all or a number of channels of my PRI which is connected to the dutch telephony network, Asterisk keeps on working fine.... Here's an example where channel 1-24 went into alarm: WARNING[90124]: File chan_zap.c, Line 4139 (handle_init_event): Detected alarm on channel 1: Yellow Alarm WARNING[90124]: File chan_zap.c, Line 4139 (handle_init_event):
2005 Jun 13
0
Unable to support trunking .... without zaptel timing
When I start Asterisk, I receive these errors: Jun 13 16:26:05 WARNING[2870] chan_iax2.c: Unable to support trunking on user 'gv_trunk' without zaptel timing Jun 13 16:26:05 WARNING[2870] chan_iax2.c: Unable to support trunking on peer 'gv_trunk' without zaptel timing Jun 13 16:26:05 WARNING[2870] chan_iax2.c: Unable to support trunking on user 'zoom_trunk' without zaptel
2007 Apr 06
0
Yellow alarm TE110P with latest release
Hello Approximately every 15 minutes I'm getting the following error (on all channels): [Apr 7 01:34:27] WARNING[6530]: chan_zap.c:6628 handle_init_event: Detected alarm on channel 31: Yellow Alarm [Apr 7 01:34:27] WARNING[6529]: chan_zap.c:2388 pri_find_dchan: No D-channels available! Using Primary channel 16 as D-channel anyway! [Apr 7 01:34:27] == Primary D-Channel on span 1 up
2008 Mar 04
4
Mitel SX-200 + *
Does anyone have any experience getting a Mitel SX-200 EL/ML PBX system to work with *? I'm not getting inbound or outbound calls to work. (Inbound caller gets line busy tone.) SETTINGS FROM MITEL: I built a Crossover cable and connected it like this: PSTN--T1--ASTRISK--T1--OLD MITEL -Crossover Cable Pin-out: 1 - 4 2 - 5
2007 Feb 06
1
yellow alarm after weeks without trouble
Hi list, I'm getting an error on a E1 link to the telco, after some weeks of operation without trouble. I have an asterisk with a TE405 in passtrough mode: two E1 are connected to the Telco, two E1 are connected to 2 Siemens PaBX. Only 15 channels are used on each E1 (conf is attached).The system has been in production for nearly a year, and does work flawlessly for weeks, then I
2004 Dec 10
2
Integrating * with Mitel SX2000 Lite
Hi All, Our experience with * to date has been a bit limited. It's a 4xCisco 7960 network, linking our head office with a faraday caged datacenter. As a way of putting voicecomms into a sealed room, it was quick and easy to deploy, and works very well. As typically happens, we've now thought about extending the use of asterisk - and a new opportunity has cropped up. In three months
2007 May 04
5
Asterisk x legacy pabx
Hi all,as good? It would like to know if already they had had success, in the integration of the functions of asterisk, with one pabx legacy (Avaya)for that pabx avaya, could use the voicemail of asterisk. For sample, user of pabx avaya, it would have its calls directed for not attendance and busy, for asterisk and asterisk, it would send the same one for the voicemail. Best Regards Josu?
2005 Sep 20
0
Red or Yellow alarm monitoring
Before I reinvent the wheel, is anyone implementing any monitoring of PRI (or T1) Red or Yellow alarms? I would like to get notified ASAP if this occurs. Or possibly automate the fix since "service zaptel reload" seems to fix my random issue. I was thinking of using tail of the full log file, but my concern is that if there is too much traffic, I will miss the alarm, or if there is
2013 Aug 19
0
Yellow Alarm
Dear list I am facing strange issue. i have 16 PRI setup. out of 16 there are 2 cables which are giving me yellow alarm in if they are in card number 1 and works fine if i put in card2 what could be the error is it card faulty?? -- Akib Sayyed Matrix-Shell akibsayyed at gmail.com akibsayyed at matrixshell.com Mob:- +91-966-514-2243 -------------- next part -------------- An HTML attachment