Displaying 20 results from an estimated 5000 matches similar to: "PSTN line quality"
2004 Apr 10
1
Hum/bux on line
Rich Hi,
After Qwest pronounced my circuits as within spec. (yes, disconnected
from the house) I listened on the lines with my butt set. Clear of all
noise and hum. I then got my box of Cat3 and laid a circuit around the
outside of the house and into my lab. Still clear of all noise and hum.
I then connected the circuit to the Adtran and made a call. Lots of
hum and buzzz.
As I said,
2004 Apr 22
2
Adtran TA750 Noise
All,
I need help.
I have an (actually 2) Adtran TA750's with 8 FXO ports. I get a terrible
buzz on every FXO port. If I unplug the Adtran and put an analog phone
on each incoming line, I have no buzz.
I also have 2 Carrier Access Access Bank I's with 12 FXO ports. When I
plug the same analog lines into either one of those, no noise or buzz
whatsoever.
I went so far as to move the TA750
2005 Oct 12
3
Calibrating both RX and TX gain?
Hello!
I'm having an echo problem with a TDM card. The TDM card is being fed by
a channel bank just 12 or so feet away. When you put an analog handset on
the line, both the RX and TX volume seem to be just fine. However, when I
use the TDM card, I have to have an rxgain of 13.5, and even then, the
audio is relatively quiet. I'm also getting echo on these lines, so I
have turned
2006 Jan 14
4
tuning an x100p in Australia for echocancellation
>
> That would be called a milliwatt generator. It likely exists in their
> central office, but its typically used by their technicians to ensure
> new installations meet specs and sometimes in troubleshooting. Call
your
> telco repair number and see if they will give you the telephone number
> for it.
I'll try that. 1st line technical support at Telstra are not known for
2007 Oct 06
4
Help 60Hz Hum?
Hey guys,
I am trying to diagnose a hum in my FXO lines
I am using an Adtran 750 with 8 FXO ports. I am getting a pretty bad hum
on the line during a call.
I have checked the Telco side of the 66 block and there is no hum there
so it's my problem to fix.
I have tried to lower the gain but that reduces the call volume to much.
Where else should I be looking?
Setup as follows
Dell
2004 Apr 07
3
Dial-In/Out Modem Zap Channel Config. Adtran 750
I've been trying to get a Win 2000 RAS server working with my asterisk PBX for quite some time, to no avail. I've googled, I've tried loads of configurations, I've rewired phone lines, and still I am not winning the battle.
Here's my config.
PRI->T400P->Asterisk->T400P->Adtran 750(L36 Firmware)->RAS Server.
I have 4 Zap channels signalled FXO_KS to the 750
2004 Apr 10
4
Woodpeckers Revisited
Just when I thought I couldn't be wrong, I was wrong. We have
woodpeckers that drill into the arial telephone cables, and water seeps
through the holes and partially grounds the tip and/or ring wires
causing hum. I thought the hum/buz on my lines was a telco problem.
The Qwest HQ noise team assures me that my lines are within spec. Sure
enough, when I listen on the test set the lines
2006 Apr 04
2
Milliwatt Test Number List
Hello:
Does anyone know of a list of milliwatt test numbers for debugging echo?
Specifically I am looking for a milliwatt test number in Canada,
preferrably in a 416 or 905 NPA exchange....different carriers would
also be nice....ie. Bell Canada, GT, Sprint (Now Rogers Telecom)
I called Rogers NOC and asked them for the milliwatt test number....they
didn't even know what it was....so I
2004 Sep 02
1
Hard Ground (On Ring)
We have been experiencing static noise on one of our phone lines
connected to our Adtran Total Access 750 which is then connected to a
T100P card. I was convinced that, after rain storms, the static would
get worse, it was surely a problem of Verizon's. Verizon sent a field
rep out today and he told our secretary (I was busy) that there was a
hard ground on the Ring portion of the line.
2004 Jun 01
5
Adtran TSU 600
Hello,
Did anybody successfully tried upgrade Adtran TSU 600 to
firmware which is working properly with T100P and asterisk ?
B.
2004 Apr 23
0
Adtran TA750 Noise - Email found in subject
Rich,
Thanks a bunch, totally understand now and that actually makes total
sense. (no need for schematics). This also explains why I used an TA750
to go into a Nortel MICS system, using FXO and no buzz. Totally balanced
load from the analog ports on the Nortel across the 5 feet of CAT5 to
the FXO on the adtran.
Now I need to get rid of some Adtrans --- Anyone lookin to buy?
:) Thanks
2003 May 14
18
Channel banks
I need a good reliable source for channel banks. Ebay is nice but too
many variations of quality. I need one that can do 8 FXO and 16 FxS
does anyone have a particular model, other than adtran that they can
recommend???
And if possible include a source to buy from...
Thanks in advance,
Alex
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2007 Apr 15
3
Digium TE205P and channelbank
Trying to find my feet here. If I wanted to connect Asterisk to a PRI and
throw in a T1 Adtran channel bank into the mix for fax machines would the
following work?
Connect PRI line from telco to Port 1 on the Digium Wildcard TE205P.
Connect Adtran TA-624-T1 to Post 2 on the Digium Wildcard TE205P
also, would I need a crossover to the channelbank or is it a patch lead
like the connection to the
2003 May 19
1
Equipment Selection
Hello All,
Quick question here on equipment selection.
Is there any benefit to using a bunch of Adtran 850's with RCUs over 850s
with BCU L1 to interface with the T400P.
I'm looking at building a PBX with 7 channel banks. 6 x 24-port FXS and 1 x
24-port FXO. Would the RCU give me any advantage/functionality over the
BCUL1?
Thanks,
Scott
2006 Mar 02
5
Milliwatt Analyzer available
Hi,
some days ago we discused here the need for an analyzer
for the 1000 Hz tone, as opposite application to Milliwatt.
Here it is: Mwanalyze
http://planinternet.net/download/voip/asterisk/app_mwanalyze.c
It performs a Fourier analysis for a fixed frequency
and tells the amplitude.
The frequency is not limited to 1000 Hz, but can be passed
as argument. The periode duration must be a mulitple
2004 Jul 19
3
PSTN gateway implementation?
Hello,
I need help in creating a simple PSTN Gateway. This is the scenario:
-I have one client sending me VoIP traffic (they don't have asterisk, so
IAX is out of the picture for me) and I need to validate that traffic
(only accept calls coming from his IP). After that I would terminate the
calls to the PSTN network and keep logs for billing purposes.
-I have a TE405P board and
2009 Aug 13
2
PRI Gateway - Worth it?
Hi all,
I was looking to build a SIP-to-PRI gateway using Asterisk (as in my other post), but there is also an alternative of using a Cisco router with something like an NM-HDV module with a T1 VIC module and DSP channel banks.
The question is, would it be more reliable to offload all dahdi/zaptel/libpri type stuff to a dedicated gateway device (Asterisk or Cisco) and have the Asterisk PBX only
2004 May 25
1
Problem - Adtran TSU 600, t100p
Hello,
I have just received Adtran TSU 600 with 24 FXS ports.
I have installed sucessfuly T100P card.
Adtran is connected to t100p with crossover T1 cable.
On T100P card I have a green light and on Adtran I do not get any
errors or alarms.
But I do not get dialtone on FXS ports.
Adtran is configured: For Network Timing, fxs ports ore fxs_ls on Adtran.
In zaptel.conf:
span=1,1,0,esf,b8zs
2005 Mar 29
1
Test Line
Hi,
Somewhere in the Wiki I read that the best way to adjust the rxgain and
txgain is to dial a "type 102 milliwatt test line".
This line is usually found in xxx-958-nnnn or xxx-959-nnnn ranges.
I'm in area code 323 in Los Angeles.
Does anybody know the test number here??
Thanks,
-N
2005 Jan 28
4
ISDN Hardware
I have a test install set up as follows
Grandstream 102 ---- Asterisk ---- X100P ---- Adtran Express 3000 ---
ISDN line to PSTN
Most things I want to do work fine except I do have some intermittent
problems with an echo. I am assuming that this is created in the link
between the X100P and the Adtran terminal adaptor.
I am not sure of the proper terms but on the PSTN side of the Adtran
there is