Displaying 20 results from an estimated 100 matches similar to: "Delivery Notification: Delivery has failed"
2003 May 22
2
Symbol NetVision phone with chan_h323 - Complete Success!
Just thought I'd share my success with chan_h323 and our Symbol NetVision
phone (4046-100-US).
Voice quality is excellent, and setup was trivial. The new NetVision
firmware (4.21) is much better than the 3.x stuff. It gives the phone a
whole new look and feel.
The hardest (and longest) part was getting OpenH323 compiled. After that,
H.323 ran out of the box. I simply uncommented
2012 Apr 16
2
Snmp-ups/netvision driver for Socomec UPS
Hello
We have an Socomec Sicon Netys PR3000 UPS equipped with NetVision
Web/SNMP adaptor. I try to monitor the ups using snmp-ups driver and
netvision mibs set. The snmp-ups driver starts correctly and connects to
the UPS, upsd confirms it, but upsmon constantly shows "No
communication" error
I think the cause is the SNMP adapter reports the UPS status as "ECO
mode"
2014 Oct 01
2
Socomec ITYS 3000 + Netvision upsmon output
Hi,
I have UPS Socomec ITYS 3000 with Netvision card.
OS is Centos 6.5 64-bit.
NUT installed with yum,.
nut-2.6.5-2.el6.x86_64
nut-client-2.6.5-2.el6.x86_64
Why is ups.status empty?
Here is upsc output:
upsc myups at localhost
battery.charge: 97.00
battery.runtime: -60.00
battery.voltage: -0.10
device.mfr: Net Vision v6.01 (SN 0101414290)
device.model: ITYS 3 kVA
device.serial: 3I14450043
1998 Feb 26
1
browse lists
Hi,
I was just wondering if there's a way to limit what's in the browse list
that nmbd announces. Could nmbd be made to filter out
certain machines? It's just that our local browse list is cluttered with
NT workstations running the server service. I've done the rounds and
turned these off manually, but people keep on enabling them. It seems
the only other alternative is to put a
2014 Feb 19
0
NetVision 6.0 MIB
2014-02-12 10:13 GMT+01:00 <hamid.nabil at coop.no>:
> Arnaud,
>
>
>
> I see your name all over when I look for Netvision MIB. Thought maybe you
> can help me. I want the MIB for our UPS (SOCOMEC) with NetVision 6.0
>
>
>
> I appreciate your help in advanceJ
>
> Regards
>
> Hamid Nabil
>
>
>
Hello Hamid,
the procedure describing how to do
2015 Feb 04
1
netvision-mib driver
Hi Henning,
note that I've cc'ed the NUT users list for info.
2015-02-04 13:47 GMT+01:00 Henning Fehrmann <henning.fehrmann at aei.mpg.de>:
> Hi Arnaud,
>
> > the best to process the value would be to have the MIB definition for
> > upsAlarmOnBattery, as for example:
> > [1]
>
2006 May 09
1
SNMP-UPS with Sicon Masterys MC
Hello,
I have in production one big ups of 30 kVA (MAS-MC 330). I bought
recently one Netvision SNMP card and NUT is working with snmp-ups
driver:
battery.charge: 100.0
battery.runtime: -60.0
battery.voltage: 483.8
driver.name: snmp-ups
driver.parameter.mibs: netvision
driver.parameter.port: xxx.xxx.xxx.xxx
driver.version: 2.0.2
driver.version.internal: 0.41
input.voltage: 219.0
output.current:
2019 Oct 11
0
NUT-DRIVER cant start [Emerson Liebert APM 150 kVA]
Hi,
I'm trying connect a device:
* OS name and version:
root at nut:/etc/nut# hostnamectl
Static hostname: nut
Icon name: computer-vm
Chassis: vm
Machine ID: d7a3b7fc724f4fe1a79a3d0eeff08f72
Boot ID: 40a561c464064b5184150f5909af0aa7
Virtualization: vmware
Operating System: Debian GNU/Linux 9 (stretch)
Kernel: Linux 4.9.0-9-amd64
Architecture: x86-64
* NUT version
2003 May 21
1
Symbol NetVision - anyone?
hi all
I'm trying to get this Symbol NetVision H.323/802.11b phone
(http://www.symbol.com/products/wireless/netvisionphone.html) connected to
asterisk, but it doesn't look an easy task - at least without this serial
cable.. Anyone who've succeded this?
roy
--
Roy Sigurd Karlsbakk, Datavaktmester
ProntoTV AS - http://www.pronto.tv/
Tel: +47 9801 3356
Computers are like air
2013 Oct 09
2
Updated to 2.6.5, previously-working APC SmartUPS now fails completely
Here is the upsc output:
# /usr/local/ups/bin/snmp-ups -DD -a irs2-ups1
Network UPS Tools - Generic SNMP UPS driver 0.68 (2.6.5)
0.000000 debug level is '2'
0.000327 SNMP UPS driver : entering upsdrv_initups()
0.000341 SNMP UPS driver : entering nut_snmp_init(snmp-ups)
0.056112 SNMP UPS driver : entering load_mib2nut(auto)
0.056126 trying the new
2004 Jan 13
1
Symbol NetVision Phone
Hi List !
I received an unit of the Symbol NetVision Phone and i will test it with asterisk using H.323 or Skinny , somebody tested this phone with asterisk and can share experience?
Miklos
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20040113/2ea43296/attachment.htm
2005 Jul 15
1
SYMBOL NETVISION II NP-3010
I was looking at these SYMBOL NETVISION II NP-3010 VoIP TCP/IP WIRELESS
PHONES - I know they have been discontinued.
Am I asking for trouble to buy some of these for use on Asterisk?
TIA
Bart
2014 Feb 24
2
Arch Linux and Tripp Lite web snmp card issues.
I have been working with NUT to get this working since upgrading to a
web snmp card in a UPS. I keep getting seg faults when running snmp-ups
also. Below is the output.
kernel: [1365065.178230] snmp-ups[1940]: segfault at 0 ip b7555470 sp
bf8d89e8 error 4 in libc-2.18.so[b74c2000+1a9000]
Running: Arch i686 current
Nut is current git
Device is Tripp Lite SU2200XLa with WEBSNMPCARD running
2019 Oct 08
0
APC AP9630 SNMP AES
Hello,
i'm trying to monitor a APC Smart-UPS 1000 behind a APC AP9630 Network
Management Card via SNMPv3 using the AES Privacy Protocol.
* OS name and version:
Debian 10.1
* exact NUT version:
2.7.4
* NUT installation method:
from debian package 2.7.4-8
* exact device name and related information
* Model Number AP9630
* Hardware Revision 08
* Manufacture Date
2003 Sep 18
2
Need help with H.323
hi all
I'm trying to setup a dlink dph-100h phone (actually a dph-100m but with
the h.323 software) with asterisk and chan_h323. AFACS, the dph-100h
software can only be configured to point to a gatekeeper. I know I don't
need to do this, but it's a test before I setup my Symbol Netvision
phones (I don't have an access point for them now). First, this is what
I have, and what
2014 Aug 06
1
process_lanman_packet: Discarding datagram from IP x.x.x.x. Source name LINUX<00> is one of our names !
Aug 6 11:21:44 linux nmbd[2193]: [2014/08/06 11:21:44.614859, 0]
../source3/nmbd/nmbd_packets.c:1174(process_lanman_packet)
Aug 6 11:21:44 linux nmbd[2193]: process_lanman_packet: Discarding
datagram from IP 192.168.1.6. Source name LINUX<00> is one of our names !
Aug 6 11:22:50 linux nmbd[2193]: [2014/08/06 11:22:50.279516, 0]
2014 Feb 25
2
Arch Linux and Tripp Lite web snmp card issues.
On 2/24/2014 11:10 PM, Charles Lepple wrote:
> On Feb 24, 2014, at 10:29 PM, Jason R Begley wrote:
>
>> Thanks for the quick response Charles! I may not have gotten the correct output from the snmpwalk, let me know if the attachment is usable. Thanks!
> Sorry, it's basically all comments. Do you have the stdout from the subdriver script? Also, how is the MIB file installed?
2014 Feb 25
2
Arch Linux and Tripp Lite web snmp card issues.
Thanks for the quick response Charles! I may not have gotten the correct
output from the snmpwalk, let me know if the attachment is usable. Thanks!
New data added, here is the gdb output:
Reading symbols from /usr/bin/snmp-ups...(no debugging symbols
found)...done.
(gdb) run -a tripplite -DD
Starting program: /usr/bin/snmp-ups -a tripplite -DD
warning: Could not load shared library symbols for
2003 Feb 25
0
gastman manual?
hi
I'm running SIP (msn messenger), MGCP (dlink hardphone), H.323 (soon -
netvision 802.11 phone) and CAPI (AVM C2). Can I plot in the known extensions
and use gastman to tranfer calls? I've tried, but no calls was visualized
from the extensions I created ...
and - no - I couldn't find it after RTFM
roy
--
Roy Sigurd Karlsbakk, Datavaktmester
ProntoTV AS - http://www.pronto.tv/
2016 Aug 12
0
SMART-UPS 2200 RM: No supported device detected
Hi,
I have two UPS SMART-UPS 2200 RM both of them have the same
configuration.One of them works fine, but the other one it doesn't, it
output as follows:
snmp-ups -D -a nutdev10
Network UPS Tools - Generic SNMP UPS driver 0.72 (2.7.2)
0.000000 debug level is '1'
0.001013 SNMP UPS driver : entering upsdrv_initups()
0.048606 trying the new match_sysoid() method