search for: yourupsnam

Displaying 5 results from an estimated 5 matches for "yourupsnam".

Did you mean: yourupsname
2020 Sep 25
2
reset "replace battery" flag
...; alarm that stays (...): >> The panel doesn't show any battery-related alarm. >> Anybody has a clue how I should proceed or debug the issue? > try to run the driver in debug mode so that we can see what data is actually > sent by the UPS > #usbhid-ups -DDDD -u root -a $YourUpsName > where $YourUpsName is the one you used in /etc/ups/ups.conf > After a few seconds the output will start to repeat so ctrl-c and examine > whatever was collected. and maybe zip it and send it to the list. I attach the output. I looked for "replace" and "battery" in...
2020 Sep 21
4
reset "replace battery" flag
Hi, We have a HP R/T 3000 G4 UPS; according to the data returned by the usbhid-ups driver, it seems to be a "badge engineered" Eaton 5PX UPS LI R 3000. We have a stubborn "Replace Battery" alarm that stays despite: - physical battery replacement - successful quick battery test, started by upscmd - successful deep battery test, started by upscmd - successful battery test,
2020 Sep 24
0
reset "replace battery" flag
...disk > where that is/was, and restarting all NUT daemons & drivers didn't > help either. > > Anybody has a clue how I should proceed or debug the issue? try to run the driver in debug mode so that we can see what data is actually sent by the UPS #usbhid-ups -DDDD -u root -a $YourUpsName where $YourUpsName is the one you used in /etc/ups/ups.conf After a few seconds the output will start to repeat so ctrl-c and examine whatever was collected. and maybe zip it and send it to the list.
2020 Sep 25
0
reset "replace battery" flag
...ys (...): >>> The panel doesn't show any battery-related alarm. >>> Anybody has a clue how I should proceed or debug the issue? >> try to run the driver in debug mode so that we can see what data is actually >> sent by the UPS >> #usbhid-ups -DDDD -u root -a $YourUpsName >> where $YourUpsName is the one you used in /etc/ups/ups.conf >> After a few seconds the output will start to repeat so ctrl-c and examine >> whatever was collected. and maybe zip it and send it to the list. > I attach the output. I looked for "replace" and "ba...
2020 Sep 30
2
reset "replace battery" flag
...ups driver, it seems to be a "badge engineered" Eaton >>> 5PX UPS LI R 3000. >>>> We have a stubborn "Replace Battery" alarm that stays (...): >>>> The panel doesn't show any battery-related alarm. >>> #usbhid-ups -DDDD -u root -a $YourUpsName >>> After a few seconds the output will start to repeat so ctrl-c and examine >>> whatever was collected. and maybe zip it and send it to the list. >> I attach the output. I looked for "replace" and "battery" in there, >> and nothing obviously un...