2014 Aug 20
0
win7 x64 victron driver exiting with error
...S Victron NetPro connected via serial port When I run driver when UPS cable is connected to computer's serial port it exits with following output victronups - -DDDD -a victron Network UPS Tools -GE/IMU/Victron UPS driver 0.20 (2.6.5.-3723:3731M) 0.000000 debug level is "4" 0.000000 w32_serial_open (COM1) 0.000000 setting initial state on COM1 0.015600 0000000050 = w32_serial_open (COM1) 0.015600 Warning: no locking method is available: No error 0.015600 tcgetattr(COM1): Input/output error But... when I run the driver and few seconds later connect the cable to serial port it works correctly....
2015 May 13
0
Problem connecting to APC Smart UPS SC1000 on Windows
...oblem with connecting to APC SC1000 using NUT port for windows 2.6.5-6. Last working version is NUT 2.6.1-1. With the same config files it works well. c:\NUT\bin>apcsmart.exe -a SC1000 Network UPS Tools - APC Smart protocol driver 3.1 (Windows-v2.6.5-5-7-g72f380c) APC command table version 3.1 w32_serial_open (COM3) setting initial state on COM3 0000007C = w32_serial_open (COM3) Warning: no locking method is available: No error [+?????? ??????? ?????????. ] vmin_ 0, vtime_ 0 action 0 vtime 0, vmin 1 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1, ReadTotalTimeoutMultiplier -1 vmin_ 1, vtime_ 0 a...
2016 Jul 20
0
port for powercom
...'powercom' driver instead. So I switched to the powercom driver, but I have tried a whole bunch of likely suspects for the port setting, none of which have worked Tried so far:- com1 with these results:- Network UPS Tools - PowerCom protocol UPS driver 0.13 (Windows-v2.6.5-5-7-g72f38 0c) w32_serial_open (com1) setting initial state on com1 0000005C = w32_serial_open (com1) Warning: no locking method is available: No error [The operation completed succe ssfully. ] vmin_ 0, vtime_ 0 action 0 vtime 0, vmin 1 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1, ReadTotalTimeoutMultiplier -1 data rece...
2018 Nov 29
0
Problem to connect to APC SC1500
...PS: APC SC 1500VA Driver: apcsmart upsdrvctl.exe start outputs this errors: ---------------------------------------------------------------------------------------------------------------- Network UPS Tools - APC Smart protocol driver 3.1 (Windows-v2.6.5-5-7-g72f380c) APC command table version 3.1 w32_serial_open (COM4) setting initial state on COM4 000000A8 = w32_serial_open (COM4) Warning: no locking method is available: No error [Der Vorgang wurde erfolgreich beendet. ] vmin_ 0, vtime_ 0 action 0 vtime 0, vmin 1 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1, ReadTotalTimeoutMultiplier -1 vmin_ 1,...
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
...zer_ser port = com6 desc = "Proline UPS" Here is the output from blazer_ser not working: C:\Program Files (x86)\NUT\bin>blazer_ser -ups *-DDD* -a myups Network UPS Tools - Megatec/Q1 protocol serial driver 1.55 (2.6.5-3780M) 0.000000 debug level is '3' 0.002000 w32_serial_open (com6) 0.177010 setting initial state on com6 0.231013 00000050 = w32_serial_open (com6) 0.236014 Warning: no locking method is available: No error [The operation completed successfully. ] 0.244014 vmin_ 0, vtime_ 0 0.346020 action 0 0.398023 vtime 0, vmin...
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
...ll: SETINFO driver.parameter.id "610,1000,230,230,10.0,36.0" 0.000000 send_to_all: SETINFO driver.parameter.nombattvolt "41.1" 0.015625 send_to_all: SETINFO driver.parameter.battvoltmult "18" 0.015625 debug level is '7' 0.015625 w32_serial_open (com1) 0.015625 setting initial state on com1 0.015625 000007AC = w32_serial_open (com1) 0.015625 Warning: no locking method is available: No error [The operation completed successfully. ] 0.015625 vmin_ 0, vtime_ 0 0.109376 action 0 0.109376 vtime 0...
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
...hout command 'E'. However, command 'T' reports the UPS power on hours in decimal format xxx.x Thank you in advance, Markus Pruehs ups.conf: [600LS] driver=apcsmart port=COM1 C:\Programme\NUT\bin>apcsmart -a 600LS -DDDDD 0.000000 debug level is '5' 0.000000 w32_serial_open (COM1) 0.010014 setting initial state on COM1 0.010014 000007D0 = w32_serial_open (COM1) 0.010014 Warning: no locking method is available: No error [Der Vorgang wurde erfolgreich beendet. ] 0.020029 vmin_ 0, vtime_ 0 0.120173 action 0 0.120173 vtime 0, vmin...
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
...pecified, battery.charge drops to zero. I have not investigated (2), but I did do some digging regarding one above. When running with -DDDDD, I get the following: Network UPS Tools - Megatec/Q1 protocol serial driver 1.55 (2.6.5-3780M) 0.000000 debug level is '5' 0.000000 w32_serial_open (com1) 0.000000 setting initial state on com1 0.000000 000007D0 = w32_serial_open (com1) 0.000000 Warning: no locking method is available: No error [? ????????-? ???????????? ?? ??????-?. ] 0.000000 vmin_ 0, vtime_ 0 0.109369 action 0 0.109369 vtime...