3
15-min mean values
Good day everyone, I want to use zoo(aggregate) to calculate 15-min mean values from a wind dataset which has 1-min values. The data I have looks like this: vector VDATE vector WS 1 1998-10-22:02:11 12.5 2 1998-10-22:02:12 10.1 3 1998-10-22:02:13 11.2 4 1998-10-22:02:14 10.5 5 1998-10-22:02:15 11.5 . . . n
2015 May 13
0
Problem connecting to APC Smart UPS SC1000 on Windows
Hello. I have problem with connecting to APC SC1000 using NUT port for windows 2.6.5-6. Last working version is NUT 2.6.1-1. With the same config files it works well. c:\NUT\bin>apcsmart.exe -a SC1000 Network UPS Tools - APC Smart protocol driver 3.1 (Windows-v2.6.5-5-7-g72f380c) APC command table version 3.1 w32_serial_open (COM3) setting initial state on COM3 0000007C = w32_serial_open
2007 Apr 18
0
[RFC/PATCH PV_OPS X86_64 14/17] paravirt_ops - vsyscall
plain text document attachment (xx-paravirt-vsyscall.patch) vsyscall interface updates for paravirt ops. Signed-off-by: Steven Rostedt srostedt@redhat.com Signed-off-by: Glauber de Oliveira Costa <gcosta@redhat.com> Index: clean-start/arch/x86_64/kernel/vsyscall.c =================================================================== --- clean-start.orig/arch/x86_64/kernel/vsyscall.c +++
2007 Apr 18
0
[RFC/PATCH PV_OPS X86_64 14/17] paravirt_ops - vsyscall
plain text document attachment (xx-paravirt-vsyscall.patch) vsyscall interface updates for paravirt ops. Signed-off-by: Steven Rostedt srostedt@redhat.com Signed-off-by: Glauber de Oliveira Costa <gcosta@redhat.com> Index: clean-start/arch/x86_64/kernel/vsyscall.c =================================================================== --- clean-start.orig/arch/x86_64/kernel/vsyscall.c +++
2018 Nov 29
0
Problem to connect to APC SC1500
Hello, I am not able to get NUT working with a APC SC1500. The ups has only a serial port and came with a 940-0272a serial to usb cable. The cable has a fake Prolific chip in it, so only works by downgrading the driver to version 3.2. I tested a 940-0024C cable without success as well. The ups works with powerchute and apcupsd with the 940-0272a cable. Have not tested it with the other one. OS:
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
Hi, I have a bunch of UPSs, most connected to pcs with Linux working 100% with NUT. The only one I have a problem with, is connected to Windows 7 64bit, and I used the straight MSI installed from the website named NUT-Installer-2.6.5-4.msi Took me a while to find a way to get it to work, but it is ugly for now. Just starting up the service results in a NUT not working at all, and I tracked it
2008 Jan 16
8
PATCH [xenconsoled]: makes pty slave raw early
Hi, on my system (Linux 2.6.18.8 - ia64), if a domain write on the xencons before xenconsole is initialized the domain gets back what it wrote. This patch fixes this issue by making raw the pty slave very early. (I suppose it doesn''t happen with linux as a guest because it takes a little bit of time before writing to xencons). Tristan. _______________________________________________
2006 Aug 08
1
GSM back door to shell with Centos and Palm handhelds
Hi folks, Don't know if it could be interesting or not, even useful, but past days i was spending my time trying to use an old gsm motorola v150 mobile phone to get access to my host from my palm device with pssh (http://www.sealiesoftware.com/pssh/), these are the steps i did to accomplish it, feel free to suggest or improve it, anyway i found it usefull. First, this motorolla has an usb
2009 Oct 02
1
confint fails in quasibinomial glm: dims do not match
I am unable to calculate confidence intervals for the slope estimate in a quasibinomial glm using confint(). Below is the output and the package info for MASS. Thanks in advance! R 2.9.2 MASS 7.2-48 > confint(glm.palive.0.str) Waiting for profiling to be done... Error: dims [product 37] do not match the length of object [74] > glm.palive.0.str Call: glm(formula = cbind(alive, red) ~ str,
2016 Jul 20
0
port for powercom
Ok, so I previously thought I had to use usbhid-ups but when I eventually got it going this is what I got:- This Powercom device (0d9f/0002) is not supported by usbhid-ups. Please use the 'powercom' driver instead. So I switched to the powercom driver, but I have tried a whole bunch of likely suspects for the port setting, none of which have worked Tried so far:- com1 with these
2005 Nov 18
2
x windows and i810 chipset
I have an i810 chipset and am trying to set a custom mode. X is not taking that mode. Has anyone else run into this situation? How do I get X to take the mode on an i810 driver. Jerry
2008 Mar 20
1
[RFC/PATCH 05/15] kvm-s390: s390 arch backend for the kvm kernel module
From: Carsten Otte <cotte at de.ibm.com> From: Christian Borntraeger <borntraeger at de.ibm.com> From: Heiko Carstens <heiko.carstens at de.ibm.com> This patch contains the port of Qumranet's kvm kernel module to IBM zSeries (aka s390x, mainframe) architecture. It uses the mainframe's virtualization instruction SIE to run virtual machines with up to 64 virtual CPUs
2008 Mar 20
1
[RFC/PATCH 05/15] kvm-s390: s390 arch backend for the kvm kernel module
From: Carsten Otte <cotte at de.ibm.com> From: Christian Borntraeger <borntraeger at de.ibm.com> From: Heiko Carstens <heiko.carstens at de.ibm.com> This patch contains the port of Qumranet's kvm kernel module to IBM zSeries (aka s390x, mainframe) architecture. It uses the mainframe's virtualization instruction SIE to run virtual machines with up to 64 virtual CPUs
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
Hello all, long time away from this list, glad to be around again! I have this Powercom Vanguard VGN VGD-20K31. Some details of this model: * 3-phase input, single phase output * Model has 240V / 12V9AH x 20 x 2SET, plus another set of 20 batteries. All in all, 3 sets * Serial connection to Windows 2k3 server with UPSMon Now I was strongly considering replacing the bundled no-good upsmoon
2008 Nov 25
1
sio vs uart vs ucomm problems / differences
We are in the process of migrating one of our embedded apps to use uart by default instead of sio in RELENG_7 in prep for the day when sio eventually disappears. Unfortunately, the application doesnt want to work with uart with puc backed devices, but still works with sio. Stranger still, the app works with the uart driver when uart attaches to the built in com port on the isa bus. However,
2020 Jul 02
0
[PATCH 5/8] powerpc/64s: implement queued spinlocks and rwlocks
These have shown significantly improved performance and fairness when spinlock contention is moderate to high on very large systems. [ Numbers hopefully forthcoming after more testing, but initial results look good ] Thanks to the fast path, single threaded performance is not noticably hurt. Signed-off-by: Nicholas Piggin <npiggin at gmail.com> --- arch/powerpc/Kconfig
2020 Jul 06
0
[PATCH v3 4/6] powerpc/64s: implement queued spinlocks and rwlocks
These have shown significantly improved performance and fairness when spinlock contention is moderate to high on very large systems. [ Numbers hopefully forthcoming after more testing, but initial results look good ] Thanks to the fast path, single threaded performance is not noticably hurt. Signed-off-by: Nicholas Piggin <npiggin at gmail.com> --- arch/powerpc/Kconfig
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
Hello all, been 5 years since I posted on this list, glad to be back :) I have a number of X-power Tigra 1kVA online UPS units. From some knowledgeable folks working for the local distributor, I learnt that from inside this looked like a Best 610 ups unit. Before, I had this UPS hooked via serial to my Windows 2003 server. For monitoring, some winpilot/upspilot software was also provided.
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master