Displaying 8 results from an estimated 8 matches for "vtime_".
Did you mean:
vtime
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
...debug level is '7'
0.015625 w32_serial_open (com1)
0.015625 setting initial state on com1
0.015625 000007AC = w32_serial_open (com1)
0.015625 Warning: no locking method is available: No error [The
operation completed successfully. ]
0.015625 vmin_ 0, vtime_ 0
0.109376 action 0
0.109376 vtime 0, vmin 1
0.125002 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTi
meoutMultiplier -1
0.125002 send_to_all: SETINFO device.type "ups"
0.125002 send_to_all: SETINFO driver.version "2.6.3-3534...
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
...debug level is '5'
0.000000 w32_serial_open (COM1)
0.010014 setting initial state on COM1
0.010014 000007D0 = w32_serial_open (COM1)
0.010014 Warning: no locking method is available: No error [Der
Vorgang wurde erfolgreich beendet. ]
0.020029 vmin_ 0, vtime_ 0
0.120173 action 0
0.120173 vtime 0, vmin 1
0.120173 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTimeoutMultiplier -1
0.120173 vmin_ 1, vtime_ 0
0.230331 action 0
0.230331 vtime 0, vmin -1
0.230331 ReadTotalTimeoutConstant -2, Re...
2015 May 13
0
Problem connecting to APC Smart UPS SC1000 on Windows
...e -a SC1000
Network UPS Tools - APC Smart protocol driver 3.1
(Windows-v2.6.5-5-7-g72f380c)
APC command table version 3.1
w32_serial_open (COM3)
setting initial state on COM3
0000007C = w32_serial_open (COM3)
Warning: no locking method is available: No error [+?????? ???????
?????????. ]
vmin_ 0, vtime_ 0
action 0
vtime 0, vmin 1
ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTimeoutMultiplier
-1
vmin_ 1, vtime_ 0
action 0
vtime 0, vmin -1
ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTimeoutMultiplier
-1
vmin_ -1, vtime_ 0
COM3: device reports different attributes...
2018 Nov 29
0
Problem to connect to APC SC1500
...-
Network UPS Tools - APC Smart protocol driver 3.1 (Windows-v2.6.5-5-7-g72f380c)
APC command table version 3.1
w32_serial_open (COM4)
setting initial state on COM4
000000A8 = w32_serial_open (COM4)
Warning: no locking method is available: No error [Der Vorgang wurde erfolgreich beendet. ]
vmin_ 0, vtime_ 0
action 0
vtime 0, vmin 1
ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1, ReadTotalTimeoutMultiplier -1
vmin_ 1, vtime_ 0
action 0
vtime 0, vmin -1
ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1, ReadTotalTimeoutMultiplier -1
vmin_ -1, vtime_ 0
COM4: device reports different attributes...
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
...ebug level is '5'
0.000000 w32_serial_open (com1)
0.000000 setting initial state on com1
0.000000 000007D0 = w32_serial_open (com1)
0.000000 Warning: no locking method is available: No error [?
????????-?
???????????? ?? ??????-?. ]
0.000000 vmin_ 0, vtime_ 0
0.109369 action 0
0.109369 vtime 0, vmin 1
0.109369 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTi
meoutMultiplier -1
0.109369 vmin_ 1, vtime_ 0
0.109369 action 0
0.109369 vtime 0, vmin -1
0.109369 ReadTotalTimeoutConsta...
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
...0 debug level is '3'
0.002000 w32_serial_open (com6)
0.177010 setting initial state on com6
0.231013 00000050 = w32_serial_open (com6)
0.236014 Warning: no locking method is available: No error [The
operation completed successfully. ]
0.244014 vmin_ 0, vtime_ 0
0.346020 action 0
0.398023 vtime 0, vmin 1
0.401023 ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1,
ReadTotalTimeoutMultiplier -1
0.408024 vmin_ 1, vtime_ 0
0.410024 action 0
0.412024 vtime 0, vmin -1
0.414024 ReadTotalTimeoutConstant -2, Read...
2016 Jul 20
0
port for powercom
...com1 with these results:-
Network UPS Tools - PowerCom protocol UPS driver 0.13 (Windows-v2.6.5-5-7-g72f38
0c)
w32_serial_open (com1)
setting initial state on com1
0000005C = w32_serial_open (com1)
Warning: no locking method is available: No error [The operation completed succe
ssfully. ]
vmin_ 0, vtime_ 0
action 0
vtime 0, vmin 1
ReadTotalTimeoutConstant -2, ReadIntervalTimeout -1, ReadTotalTimeoutMultiplier
-1
data receiving error (0 instead of 11 bytes)
^C
Com3 gives same result, nothing else I have tried (com2, com4, com5, com6, usb, usb0, usb1, usb2, usb3) gives me any results.
Does anybody...
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of
2011)
Here is my configs:
nut.conf:
*
*
MODE = netserver
ups.conf:
*
*
[KIN1500]
driver = powercom
port = notUsed
desc = "Powercom KING PRO KIN-1500AP RM"
upsd.conf:
*
*
LISTEN 192.168.1.2 3493
upsd.users:
*
*
[monuser]
password = xxxxxxxx
upsmon master